MANUAL
CONGRATULATIONS
to the purchase of your new professional switch mode battery charger.
This charger is included in a series of professional chargers from CTEK SWEDEN AB and
represents the latest technology in battery charging.
SUPPLY PLUG*
MAINS CABLE
CTEK COMFORT CONNECT
CHARGE CABLE
MODE
AGM
NORMAL
SUPPLY
CTEK COMFORT CONNECT – eyelet M8
*Supply p lugs may dif fer to suit yo ur wall socket.
MXS 7.0
SUPPLY
RECOND
RECOND
12V/7A
CTEK COMFORT CONNECT – clamp
CHARGING
1. Connect the charger to the battery.
2. Connect the charger to the wall socket. The power lamp will indicate that the mains
cable is connected to the wall socket. The error lamp will indicate if the battery clamps
are incorrectly connected. The reverse polarity protection will ensure that the battery
or charger will not be damaged.
3. Press the MODE-button to select charging program.
4. Follow the indication lamps through the charging process.
The battery is ready to start the engine when
The battery is fully charged when is lit.
5. Stop charging at any time by disconnecting the mains cable from the wall socket.
ABSORPTION, READY TO USE
ANALYSE
DESULPHATION
SOFT START BULK
ERROR LAMP
MODE-
BUTTON
POWER
LAMP
NORMAL
BATTERY
PROGRAM
AGM
BATTERY
PROGRAM
SUPPLY
PROGRAM
is lit.
FLOAT, FULLY CHARGED
PULSE, MAINTENANCE CHARGING
RECOND
PROGRAM
EN
EN • 3
20015462E MXS 7.0, Manual EU, Print file 002.indd 3 2011-10-11 07:58:00
CHARGING PROGRAMS
Settings are made by pressing the MODE-button. After about two seconds the charger
activates the selected program. The selected program will be restarted next time the
charger is connected.
The table explains the different Charging Programs:
Program
NORMAL
AGM
Battery
Size (Ah)
14–225Ah
14–225Ah
Explanation Temp range
Normal battery program
14.4V/7A. Use for WET batteries,
Ca/Ca, MF and for most GEL batteries
AGM battery program 14 .7V/7A
Use for AGM batteries.
+5°C–+5 0°C
(41ºF–122ºF)
-20°C–+5°C
(-4ºF–41ºF)
ERROR LAMP
If the error lamp is lit, check the following:
1. Is the chargers positive lead connected to the
batterys positive pole?
2. Is the charger connected to a 12V battery?
3. The clamps are short circuited?
4. Has charging been interrupted in
Restart the charger by pressing the MODE-button. If charging is
still being interrupted, the battery...
...is seriosly sulphated and may need to be replaced.
...can not accept charge and may need to be replaced.
...can not keep charge and may need to be replaced.
or ?
RECOND
Recond program 15. 8V/1.5A
Use to return energy to the empty
WET and Ca/Ca batteries. Recond
your battery once per year and after
deep dischare to maximise lifetime and
14–225Ah
14–225Ah
capacity. The Recond program adds the
Recond step to the normal battery
program. Frequent use of the Recond
program may cause water loss in the
batteries and reduce service life of
electronics. Contact your vehicle and
battery supplier for advice.
Supply program 13 .6V/7A
Use as 12V power supply or use for
float maintenance charging when 100%
capacity of the battery is required.
Supply program activates Float step
without time or voltage limitation.
The spark protection on the battery charger
is disabled during SUPPLY program.
WARNING!
-20°C–+5 0°C
(-4ºF–122ºF)
-20°C–+5 0°C
(-4ºF–122ºF)
READY TO USE
The table shows the estimated time for empty battery to 80% charge
BATTERY SIZE (Ah)
20Ah
50Ah
100Ah
150Ah
TIME TO 80% CHARGED
2h
6h
12h
17h
4 • EN
20015462E MXS 7.0, Manual EU, Print file 002.indd 4 2011-10-11 07:58:02