MXS 3.8
CONGRATULATIONS
on the purchase of your new professional switch mode battery charger. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the latest technology in batter y charging.
SUPPLY PLUG*
CTEK COMFORT CONNECT
CHARGE CABLE
CTEK COMFORT CONNECT – clamp
CTEK COMFORT CONNECT – eyelet M6
* Supply plu gs may d iff er to suit your wall socket.
HOW TO CHARGE
1. Connect the charger to the batter y.
2. Connect the charger to the wall socket. The power lamp will indicate that the mains cable is connected to the wall socket. The error lamp will indicate if the battery clamps are incorrectly connected. The reverse polarity protection will ensure that the battery or charger will not be damaged.
3.Press the MODE-button to select charging program.
4. Follow the 7-step display through the charging process. The battery is ready to start the engine when STEP 4 is lit. The battery is fully charged when STEP 6 is lit.
5. Stop charging at any time by disconnecting the mains cable from the wall socket.
FULLY CHARGEDREADY TO USE
ERROR LAMP
POWER LAMP
MODE BUTTON
MODE
SMALL
BATTERY
PROGRAM
NORMAL
BATTERY
PROGRAM
COLD
WEATHER
PROGRAM
EN
EN • 3
CHARGING PROGRAMS
Settings are made by pressing the MODE-button. After about t wo seconds the charger activates the selected program. The selected program will be restarted next time the charger is connected.
The table explains the different Charging Programs:
Program
4 • EN
Battery
Size (Ah)
1. 2–14 Ah
14–13 0 A h
14–13 0 A h
Explanation Temp range
Small battery program
14.4V/0.8A Use for smaller batteries.
Normal bat ter y program
14.4V/3.8A
Use for WE T batteries, Ca/Ca, MF, GEL batteries and many AGM batteries.
Cold weather program
14.7V/3.8A
Use for charging at low tempera­tures and for power AGM batter­ies like Optima and Odyssey.
-2 0°C –+50°C
(-4ºF–122ºF)
+5°C–+5 0°C
(41ºF–122ºF)
-2 0°C –+5°C
(-4ºF–41ºF)
ERROR LAMP
If the error lamp is lit, check the following:
1. Is the chargers positive lead connected to the battery´s positive pole?
2. Is the charger connected to a 12V battery?
3. Has charging been interrupted in STEP 1, 2 or 5?
Restart the charger by pressing the MODE- button. If charging is still being interrupted, the battery...
STEP 1: ...is seriously sulphated and may need to be replaced. STEP 2 : ...can not accept charge and may need to be replaced. STEP 5: ...can not keep charge and may need to be replaced.
POWER LAMP
If the power lamp is lit with a:
1. STEADY LIGHT
The mains cable is connected to the wall socket.
2. FLASHING LIGHT:
The charger has entered the energy save mode. This happens if the charger isn´t connected to the battery in 2 minutes.
READY TO USE
The table shows the estimated time for empt y battery to 80% charge
BATTERY SIZE (Ah)
2Ah
8Ah 20Ah 60Ah 80Ah
TIME TO 80% CHARGED
2h 8h
5h 15h 20h