MANUAL
CONGRATULATIONS
to the purchase of your new professional switch mode battery charger.
This charger is included in a series of professional chargers from CTEK SWEDEN AB and
represents the latest technology in battery charging.
SUPPLY PLUG*
CTEK COMFORT CONNECT
CHARGE CABLE
CTEK COMFORT CONNECT – eyelet M6
* Supply plugs may di ffer to suit your wall socket.
MODE
CTEK COMFORT CONNECT – clamp
MXS 3.6
12V/3.6A
MAINS CABLE
CHARGING
1. Connect the charger to the battery.
2. Connect the charger to the wall socket. The Standby lamp will indicate that the mains
cable is connected to the wall socket. The error lamp will indicate if the battery clamps
are incorrectly connected. The reverse polarity protection will ensure that the battery
or charger will not be damaged.
3. Press the MODE-button to select charging program.
4. Follow the indication lamps through the charging process.
The battery is fully charged when
5. Stop charging at any time by disconnecting the mains cable from the wall socket or by
setting the charger on Standby.
MODEBUTTON
DESULPHATION
ERROR LAMP
STANDBY
ABSORPTION
MODE
SMALL
BATTERY
PROGRAM
BULK
is lit.
NORMAL
BATTERY
PROGRAM
FULLY CHARGED
PULSE , MAINTENANCE CHARGING
COLD
WEATHER
PROGRAM
EN
20015449F Manual MXS 3.6, EU. Print file 006.indd 3 2011-10-10 16:36:19
EN • 3
CHARGING PROGRAMS
Settings are made by pressing the MODE-button. After about two seconds the charger
activates the selected program.
The table explains the different Charging Programs:
Program
Battery
Size (Ah)
7–14 Ah
14–120Ah
14–120Ah
Explanation Temp range
Small battery program
14.4V/0.8A
Use for smaller batteries.
Normal battery program
14.4V/3.6A
Use for WET batteries, Ca/Ca,
MF, GEL batteries and many
AGM batteries.
Cold weather program
14. 7V/3.6A
Use for charging at low temperatures and for power AGM batteries like Optima and Odyssey.
-20°C–+5 0°C
(-4ºF–122ºF)
+5°C–+5 0°C
(41ºF–122ºF)
-20°C–+5°C
(-4ºF–41ºF)
ERROR LAMP
If the error lamp is lit, check the following:
— Is the chargers positive lead connected to the
batterys positive pole?
— Connect the charger according to page 5.
READY TO USE
The table shows the estimated time for empty battery to 80% charge
BATTERY SIZE (Ah)
7Ah
20Ah
60Ah
75Ah
4 • EN
TIME TO 80% CHARGED
7h
5h
13h
17h
CHARGING PROGRAM
DESULPHATION BULK ABSORPTION
VOLTAGE (V)CURRENT (A)
1
1
14.4V 14.4V
14.4V 14.4V
14.7V 14.7V
STEP 1 DESULPHATION
Detects sulphated batteries. Pulsing current and voltage, removes sulphate from the lead plates
of the battery restoring the battery capacity.
STEP 2 BULK
Charging with maximum current until approximately 80% battery capacity.
STEP 3 ABSORPTION
Charging with declining current to maximize up to 100% battery capacity.
STEP 4 PULSE
Maintaining the battery at 95–100% capacity. The charger monitors the battery voltage and
gives a pulse when necessar y to keep the battery fully charged.
2 3 4
Increasing voltage
to 14.4V
0.8A
Increasing voltage
to 14.4V
3.6A
Increasing voltage
to 14.7V
3.6A
Declining current
Declining current
Declining current
PULSE
12.9V‒14.4V
0.8‒0.4A
12.9V‒14.4V
3.6A
12.9V‒14.7V
3.6A
Charge cycle restarts
if voltage drops
20015449F Manual MXS 3.6, EU. Print file 006.indd 4 2011-10-10 16:36:20