CTEK 250TS User Manual

EN
EN • 3
MANUAL
CONGRATULATIONS
Congratulations on purchasing your new CTEK professional 24V DC/DC switch mode battery charger, 12V converter and battery equalizer. This charger is part of a range of professional bat­tery chargers from CTEK SWEDEN AB. It represents the latest technology in battery charging with charging and analysis in 4 steps with temperature compensation.
Read this User Manual and follow the instructions carefully before using your new charger.
SAFETY
The charger is designed for 24V lead-acid batteries mounted into vehicles. Do not use the charger for any other purpose
Use safety glasses when connecting or disconnecting a battery.
Battery acid is corrosive. Rinse immediately with water if acid comes into contact with skin or eyes. Seek medical advice.
Make sure that the cables are not being pinched or in contact with warm surfaces or sharp edges.
While charging, a battery can emit explosive gases, avoid sparks in the immediate area.
Always provide for proper ventilation during charging.
Avoid covering the charger.
Starter Battery
24V+
Service Battery
24V+
Service ground
Service Battery Midpoint
D250TS
The D250TS has one 24V i nput and two alterna ting outputs. One ou tput charge a 24V batter y and the other provid es 50% of the input voltage to t he midpoint of a 24V system. T his enables co nnection of 12V consumers to t he battery stri ng and also equalizin g this battery string, fo r longer batter y life.
D250TS
FEATURES:
Multi-step10A temperature compensated battery charging and battery maintenance.
• Batter y separation of Starter and Service batteries.
• Equalization of Ser vice batteries
• Makes connection of 12V consumers directly to 24V Service battery possible.
• When the charger is correctly connected the charger will output 24V on the status signal wire. Connection of a 24V lamp (max 2W) to the status signal wire will indicate a correctly con­nected charger.
• The charger will maintain the starter batter y untill the supply is below 14V. To avoid draining the service battery always connect a charger to the service battery when the vehicle is not used for a longer period.
+IN +OUT
EQU
D250TS
Status signal wire
Temperature sensor
20015884C D250TS, Manual, Print file 002.indd 3 2011-12-20 13:27:12
4 • EN
INSTALLATION OF UNIT
1. Attach the temperature sensor holder on a flat surface on one Starter battery. Position it as close as possible to a positive post.
2. Use the included drill template. Wiring is simplified if the units are installed according to the drill template, but other setups are possible.
3. Install the unit(s) on a flat surface where it can be properly fixed and where the unit is not exposed to fuels, oils or splashes of dirt.
4. Mount the unit with screws intended for the surface and attach it with one screw in each of the four holes in the corners of the unit. See picture 1. Mount the unit with M4 or ST4.2 screws. The required torque depends on the surface for mounting.
Figure 1
2Nm
DRILL TEMPLATE
PP

PP

PP
Service ground
Service Battery
24V+
Starter Battery
24V+
Status signal wire
Temp sensor
Service Battery Midpoint
20015884C D250TS, Manual, Print file 002.indd 4 2011-12-20 13:27:13