Crown XS-4300 Brochure

Xs SERIES
Xs4300
Architectural & Engineering Specifi cations
Xs4300 (120 V, 60 Hz model)
The Crown® Xs4300 power amplifi er shall be a solid-state four-channel model employing Class B output circuitry.
The amplifi er shall include protection from shorted, open and mismatched loads, general overheating, DC, high-frequency overloads, under/over volt­age, and internal faults.
The front-panel controls shall be a power switch and a gray rotary level control (one per channel).
The recommended load impedance shall be 4 to 8 ohms. Rear-mounted input connectors shall be one per channel XLR-1/4" combo
connector including a 3-pin female XLR connector and TRS 1/4" phone jack. Rear-mounted output connectors shall be one pair per channel bind­ing posts.
Front panel indicators shall include two yellow Bridge-Mode Indicators (one for channels 1 and 2, one for channels 3 and 4) that illuminate when the Mode Switch is set to the “Bridge” position, a green Signal Indicator (one per channel) that illuminates when the channel’s input signal level is above –40 dBu, a red Clip Indicator (one per channel) that illuminates when the channel’s output signal is being overdriven, two red Temp Indicators (one for channels 1 and 2, one for channels 3 and 4) that illuminate when channel(s) are in thermal protect mode, a red Fault Indicator that illuminates when the amplifi er is in protect mode and also briefl y during normal power-up when amplifi er is fi rst switched on, a yellow Power Indicator that indicates amplifi er has been turned on, and a red AC Mains Indicator that illuminates when AC power is present at the power cord.
The power amplifi er shall meet or exceed the following performance crite­ria. Input sensitivity for rated output: 1.4V. Rated output with both channels driven in Dual mode with 0.15% THD (1 kHz): 200 watts per channel into 8 ohms and 300 watts per channel into 4 ohms. Bridge-mono output power with 0.15% THD (1 kHz): 700 watts into 8 ohms. Frequency Response at 1 watt, 22 Hz to 22 kHz: ± 1 dB. Signal to Noise Ratio below rated power: > 107 dB A-weighted. Total Harmonic Distortion at full rated power from 20 Hz to 20 kHz: < 0.5%. Damping Factor: > 200 from 10 to 100 Hz. Crosstalk (below rated power): > 57 dB at 1kHz and > 40 dB at 20 kHz. DC Output Offset (shorted input): < ± 75 mV. Input Impedance (nominal): 20 kilohms balanced, 10 kilohms unbalanced.
The amplifi er chassis shall be constructed of steel with a durable black fi nish and shall be designed for forced-air ventilation from the front panel to the back panel.
The dimensions of the amplifi er shall allow for 19 inch (48.3 cm) EIA standard (RS-310-B) rack mounting. The amplifi er shall be 3.5 inches (8.9 cm) tall, and 17.14 inches (43.5 cm) deep behind the rack-mounting surface.
The amplifi er shall weigh 28 lb 14 oz (13.1 kg). The amplifi er shall be designated the Crown Xs4300.
Crown International P.O. Box 1000 Elkhart, IN 46515-1000 TEL: 574-294-8200 FAX: 574-294-8FAX www.crownaudio.com
© 2006 Crown Audio
8/06 135182-1C
®
, Inc.