OVERVIEW
APPLICATIONS
Applications for the product are primarily for setup of IQ Systems where an INT II or other interface product is not meant to be a permanent part of the system. This tool allows the installer to bring the pocket interface with him to a site, program the system with a laptop, then take his laptop and PSI with him when he leaves. This is particularly true for relatively small installations. In larger systems the PSI is very valuable for mobility, particularly when checking parts of a system that may be located remotely.
C D
POWER
RS232
ENABLE DSPI
A
POCKET SERIAL INTERFACE
B
AUX CROWN BUS
Elkhart, IN 46517 U.S.A.
1718 W. Mi shawaka Rd.
10 VDC IN
E
F G
PSI Top View PSI End View
HARDWARE
• The PSI is about the size of your hand.
• It has a black finish.
ENABLEDSPI
POCKET SERIAL INTERFACE
1718 W. Mishawaka Rd.
Elkhart, IN 46517 U.S.A.
10 VDC IN
ENABLEDSPI
ENABLE
ODEP IOC SPI
CH1 CH2
OFF
ENABLE
ODEP IOC SPI
CH1 CH2
OFF
ENABLE
ODEP IOC SPI
CH1 CH2
OFF
PSI Example Application
128 64 32 16 8 4 2
IQ ADDRESSBAUD RATE
1
12345678
ON
(DOWN)
4,800
VER:
9,600
19,200
INSIDE THE BATTERY COMPARTMENT.
38,400
1234
THE SWITCHES SHOWN BELOW ARE LOCATED
PSI Bottom View
CAUTION: USE ALKALINE BATTERY ONLY!
AUX CROWN BUS
RS232
POWER
RS232
+–+–
INPUT OUTPUT
IN OUT
+10
VDC
AUX CROWN BUS
MODEL: IQ-PSI
EXT
PWR
INPUT
S/N:
H
• Power switch (A). It connects or
POWER
disconnects power from the bat­tery or AC source. Any time the
POWER
PSI is off or loses power drop-out relays bypass the Crown Bus connection to the unit.
• Attached RS232 cable (B) with
POWER
female DB9 serial connector. The
CROWN BUS LOOP
PSI automatically senses the pres­ence of a PC at its RS232 connec­tor. If there is no PC present the unit closes its loop to operate as a component. When an RS232
connection is sensed it opens the loop to serve as interface.
• Data LED (C). It lights to indicate reception of data being addressed to the unit.
• Enable LED (D). It indicates AC or battery power is available and that the unit is switched on.
• +10 VDC input (E) for a standard AC adaptor.
• Aux port (F). It has a three pin remov­able barrier block connector. Most IQ components have such a port to pro-
IQ-PSI (Page 1 of 2)
@crown
* System
®
IQ-PSI Poc ket Serial Interface (P a ge 2 of 2)
®
Product Reference
vide a control voltage for external use as well as an entry point for a control volt­age into the system.
• Crown Bus loop connector (G). It uses a four pin removable barrier block.
SETUP
To access the battery compartment and setup switches slide the battery cover off the back panel. Before inserting a battery configure the baud and ad­dress switches as necessary. Note that no two PSI units on the same loop may have the same loop address, valid ad­dresses range from 1 to 250. Baud may be set for 38,400, 19,200, 9,600, or 4,800.
SWITCHES
1
2
3
ON
4 OFF OFF OFF
ON
BAUD
38,400 19,200
9,600 4,800
ON OFF OFF OFF
OFF
ON OFF OFF
OFF OFF
OFF
IQ2 SUPPORT
The IQ-PSI is an IQ2 component and, as an interface, it supports both IQ2 and legacy protocol.
SPECIFICATIONS
Internal Controls — One 8-segment DIP
switch to set the address, one 4-seg­ment DIP switch to set RS232 baud rate.
External Controls — Power on-off. Connectors — One 4-pin “Euro-style”
removable barrier block Crown Bus connector, one 3-pin “Euro-style” re­movable barrier block aux port connec­tor, one female 9-pin RS232 connector on attached cable, one male coaxial +10VDC external power input jack. Indicators — Green Enable LED shows unit is powered and switched on and a yellow Data LED that indicates data transmitted to/from the unit or may be forced on via software.
Power — Standard 9 VDC battery or external 10 VDC supply. Finish — Molded black high-impact sty­rene. Crown Bus Isolation — Data is optically coupled to 20 mA current loop. Data Rate — 38.4K baud on Crown Bus loops; 4.8 to 38.4K baud to computer. Data Format — Serial, binary, asynchro­nous, 1 start bit, 1 stop bit, 8 data bits, no parity. Crown Bus Interface Type — Isolated 20 mA current loop.
PC Interface Type — RS232. Operation — Half duplex. Crown Bus Transmission Distance — 300
to 3000 feet (90 to 900 m), depending on wire type, size, and capacitance. Typically 1000 feet (300 m) with shielded twisted pair 26AWG or larger; extend­able via IQ Repeater. Transmission Distance RS232 — 50 feet (15 m).
Baud Rate Selection
GENERATOR
RS-232
GENERATOR
GENERATOR
IQ ADDRESS
BAUD RATE
BAUD RATE
BAUD RATE
SWITCH
MICROPROCESSOR
PSI Basic Block Diagram
RELAYSOPTOCOUPLER
BUFFER
BUFFER
CROWN BUS
AUX
AUX
Guaranteed Excellence
@crown
Crown International, Inc.
PO Box 1000 Elkhart, IN 46515-1000
Ph. 800-342-6939/219-294-8200