OVERVIEW
The pocket interface is a product designed as a tool for use by installers
and servicers of IQ Systems. The
PSI is a physically small interface between RS232 to a computer and one Crown Bus serial data loop.
APPLICATIONS
Applications for the product are
primarily for setup of IQ Systems where
an INT II or other interface product is not
meant to be a permanent part of the
system. This tool allows the installer to
bring the pocket interface with him to a
site, program the system with a laptop,
then take his laptop and PSI with him
when he leaves. This is particularly true
for relatively small installations. In larger
systems the PSI is very valuable for
mobility, particularly when checking
parts of a system that may be located
remotely.
C D
POWER
RS232
ENABLE DSPI
A
POCKET SERIAL INTERFACE
B
AUX CROWN BUS
Elkhart, IN 46517 U.S.A.
1718 W. Mi shawaka Rd.
10 VDC IN
E
F G
PSI Top View PSI End View
HARDWARE
• The PSI is about the size of your hand.
• It has a black finish.
ENABLEDSPI
POCKET SERIAL INTERFACE
1718 W. Mishawaka Rd.
Elkhart, IN 46517 U.S.A.
10 VDC IN
ENABLEDSPI
ENABLE
ODEP
IOC
SPI
CH1 CH2
OFF
ENABLE
ODEP
IOC
SPI
CH1 CH2
OFF
ENABLE
ODEP
IOC
SPI
CH1 CH2
OFF
PSI Example Application
128
64
32
16
8
4
2
IQ ADDRESSBAUD RATE
1
12345678
ON
(DOWN)
4,800
VER:
9,600
19,200
INSIDE THE BATTERY COMPARTMENT.
38,400
1234
THE SWITCHES SHOWN BELOW ARE LOCATED
PSI Bottom View
CAUTION: USE ALKALINE BATTERY ONLY!
AUX CROWN BUS
RS232
POWER
RS232
+–+–
INPUT OUTPUT
IN OUT
+10
VDC
AUX CROWN BUS
MODEL: IQ-PSI
EXT
PWR
INPUT
S/N:
H
• Power switch (A). It connects or
POWER
disconnects power from the battery or AC source. Any time the
POWER
PSI is off or loses power drop-out
relays bypass the Crown Bus
connection to the unit.
• Attached RS232 cable (B) with
POWER
female DB9 serial connector. The
CROWN BUS LOOP
PSI automatically senses the presence of a PC at its RS232 connector. If there is no PC present the
unit closes its loop to operate as
a component. When an RS232
connection is sensed it opens the loop
to serve as interface.
• Data LED (C). It lights to indicate
reception of data being addressed to
the unit.
• Enable LED (D). It indicates AC or
battery power is available and that the
unit is switched on.
• +10 VDC input (E) for a standard AC
adaptor.
• Aux port (F). It has a three pin removable barrier block connector. Most IQ
components have such a port to pro-
IQ-PSI (Page 1 of 2)
@crown
* System
®
IQ-PSI Poc ket Serial Interface (P a ge 2 of 2)
®
Product Reference
vide a control voltage for external use as
well as an entry point for a control voltage into the system.
• Crown Bus loop connector (G). It uses
a four pin removable barrier block.
SETUP
To access the battery compartment and
setup switches slide the battery cover
off the back panel. Before inserting a
battery configure the baud and address switches as necessary. Note that
no two PSI units on the same loop may
have the same loop address, valid addresses range from 1 to 250. Baud may
be set for 38,400, 19,200, 9,600, or
4,800.
SWITCHES
1
2
3
ON
4
OFF
OFF
OFF
ON
BAUD
38,400
19,200
9,600
4,800
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
IQ2 SUPPORT
The IQ-PSI is an IQ2 component and, as
an interface, it supports both IQ2 and
legacy protocol.
SPECIFICATIONS
Internal Controls — One 8-segment DIP
switch to set the address, one 4-segment DIP switch to set RS232 baud
rate.
External Controls — Power on-off.
Connectors — One 4-pin “Euro-style”
removable barrier block Crown Bus
connector, one 3-pin “Euro-style” removable barrier block aux port connector, one female 9-pin RS232 connector
on attached cable, one male coaxial
+10VDC external power input jack.
Indicators — Green Enable LED shows
unit is powered and switched on and a
yellow Data LED that indicates data
transmitted to/from the unit or may be
forced on via software.
Power — Standard 9 VDC battery or
external 10 VDC supply.
Finish — Molded black high-impact styrene.
Crown Bus Isolation — Data is optically
coupled to 20 mA current loop.
Data Rate — 38.4K baud on Crown Bus
loops; 4.8 to 38.4K baud to computer.
Data Format — Serial, binary, asynchronous, 1 start bit, 1 stop bit, 8 data bits,
no parity.
Crown Bus Interface Type — Isolated 20
mA current loop.
PC Interface Type — RS232.
Operation — Half duplex.
Crown Bus Transmission Distance — 300
to 3000 feet (90 to 900 m), depending
on wire type, size, and capacitance.
Typically 1000 feet (300 m) with shielded
twisted pair 26AWG or larger; extendable via IQ Repeater.
Transmission Distance RS232 — 50 feet
(15 m).
Baud Rate Selection
GENERATOR
RS-232
GENERATOR
GENERATOR
IQ ADDRESS
BAUD RATE
BAUD RATE
BAUD RATE
SWITCH
MICROPROCESSOR
PSI Basic Block Diagram
RELAYSOPTOCOUPLER
BUFFER
BUFFER
CROWN BUS
AUX
AUX
Guaranteed Excellence
@crown
Crown International, Inc.
PO Box 1000 Elkhart, IN 46515-1000
Ph. 800-342-6939/219-294-8200
Fax 219-294-8301
Internet: www.crownintl.com
Trademark Notice:Trademark Notice:
Trademark Notice:
Trademark Notice:Trademark Notice:
IQ System
Crown International Inc.
®
is a registered trademark of