AC Power Draw and Thermal Dissipation:
Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.
Typical line impedance used.
Measurements made with 120VAC mains. Line current figures for 230VAC units derived by multiplying 120VAC figures by 0.5.
Data based on all channels driven.
CTs 3000
Load
At Idle (sleep mode)
1/8th Power Pink Noise 8 Ohms/Ch.
Typical of program material 16 Ohms Bridge
just at clip. 4 Ohms/Ch.
8 Ohms Bridge
2 Ohms/Ch.
4 Ohms Bridge
70/100V/Ch. 1000x2
140/200V Bridge 2000
1/3rd Power Pink Noise 8 Ohms/Ch.
Typical of program material 16 Ohms Bridge
with severe clipping. 4 Ohms/Ch.
8 Ohms Bridge
2 Ohms/Ch.
4 Ohms Bridge
70/100V/Ch. 1500x2
140/200V Bridge 3000
Rated
Power
1000x2
2000
1000x2
2000
1000x2
2000
1250x2
2500
1500x2
3000
1500x2
3000
Line Current
120VAC
Line Current
230VAC
watts in
Watts
watts out dissapated
Thermal Dissipation
Btu/hr kcal/hr
40 0 40 137 34
7.2 3.6 579 313 266 907 229
8.5 4.2 697 381 316 1079 272
9.6 4.8 790 384 405 1384 349
7.2 3.6 579 313 266 907 229
13.7 6.8 1196 835 360 1230 310
16.2 8.1 1469 1010 459 1565 395
19.2 9.6 1686 1024 662 2259 570
13.7 6.8 1196 835 360 1230 310