Crestron MMK-8X-DSW, WMKM-8X-DSW Operating Manual

Crestron MMK-8X-DSW & WMKM-8X-DSW Mud Mount Kits Installation Guide
This document was prepared and written by the Technical Documentation department at:
15 Volvo Drive
Rockleigh, NJ 07647
1-888-CRESTRON
All brand names, product names and trademarks are the property of their respective owners.
©2007 Crestron Electronics, Inc.
Crestron MMK-8X-DSW & WMKM-8X-DSW Mud Mount Kits
Contents
Mud Mount Kits: MMK-8X-DSW & WMKM-8X-DSW 1
Description.................................................................................................................................1
Setup .......................................................................................................................................... 2
Supplied Hardware......................................................................................................2
Installation...................................................................................................................4
Contact Information and Updates............................................................................................10
Further Inquiries........................................................................................................10
Future Updates ..........................................................................................................10
Return and Warranty Policies..................................................................................................11
Merchandise Returns / Repair Service ......................................................................11
CRESTRON Limited Warranty.................................................................................11
Installation Guide – DOC. 6581A Contents i
Crestron MMK-8X-DSW & WMKM-8X-DSW Mud Mount Kits
Mud Mount Kits: MMK-8X-DSW & WMKM-8X-DSW

Description

The MMK-8X-DSW mud ring is an optional accessory designed for use with the BB-8X-DSW back box and PMK-8X-DSW mounting kit to compensate for significant drywall cutout imperfections. The addition of a mud ring provides an appropriate surface for the application of plaster for a finished appearance.
The WMKM-8X-DSW mounting kit provides a complete solution for installing the TPMC-8X-DSW Wall Mount Docking Station in an existing wall or similar flat surface. Designed for post-construction applications, the WMKM-8X-DSW includes a mud ring to compensate for significant drywall cutout imperfections.
NOTE: Since the TPMC-8X-DSW contains moving parts, mounting to a stud offers more support and is therefore highly recommended. Although Crestron offers the post-construction WMKM-8X-DSW mounting option, a mounting option that is secured to a stud, such as the BB-8X-DSW or PMK-8X-DSW is highly recommended.
NOTE: If mounting into a material other than drywall (for example, wood lectern, concrete or rock) use the cutout template, available in the post-construction kit WMKM-8X-DSW. For concrete and rock mounting material, allow for proper ventilation before mounting the touchpanel.
NOTE: If necessary, consult the latest revision of the TPMC-8X-DSW Installation Guide (Doc. 6588) for a complete list of mounting options. This document is available from the Crestron website (http://www.crestron.com/manuals
).
Installation Guide – DOC. 6581A Mud Mount Kits: MMK-8X-DSW & WMKM-8X-DSW 1
Mud Mount Kits Crestron MMK-8X-DSW & WMKM-8X-DSW

Setup

Supplied Hardware

The MMK-8X-DSW consists of three parts. These parts produce an assembly that attaches to the BB-8X-DSW or PMK-8X-DSW. The WMKM-8X-DSW consists of six parts, three of which make up the MMK-8X-DSW, as well as a mounting bracket, a set of mounting screws and a cutout template.
The table below lists all parts included with the MMK-8X-DSW and WMKM-8X-DSW.
Supplied Hardware for the MMK-8X-DSW & WMKM-8X-DSW
DESCRIPTION PART NUMBER QUANTITY
Metal, Plate, Mud Ring 2017641 1
Metal, Plate, Fastener 2004825 2
Hardware, Metal, U-Type Fastener 2004121 4
Metal, Bracket, Mounting, Post-Construction (WMKM-8X-DSW only)
Screw, #06-32 x 1-1/2”, Pan, Phil (WMKM-8X-DSW only)
Overlay, Template, Wall Cutout, TPMC-8X-DSW (WMKM-8X-DSW only)
2017789 1
2007254 4
4504431 1
Dimensional Drawing – Mud Ring Plate
10.93 in
(27.76 cm)
9.72 in
(24.69 cm)
1.36 in
(3.45 cm)
9.72 in
(24.69 cm)
9.72 in
(24.69 cm)
0.40 in TYP (1.02 cm)
9.32 in
(23.66 cm)
0.05 in
(0.13 cm)
0.55 in
(1.40 cm)
2.26 in
(5.73 cm)
2 Mud Mount Kits: MMK-8X-DSW & WMKM-8X-DSW Installation Guide – DOC. 6581A
Crestron MMK-8X-DSW & WMKM-8X-DSW Mud Mount Kits
Dimensional Drawing – Fastener Plate
0.38 in
(0.96 cm)
5.90 in
(14.99 cm)
0.38 in
(0.96 cm)
Dimensional Drawing – Mounting Plate
0.63 in
(1.58 cm)
10.93 in
(27.76 cm)
12.17 in
(30.91 cm)
Dimensions for Drywall Cutout
9.32 in
(23.66 cm)
10.60 in
(26.93 cm)
0.06 in
(0.16 cm)
0.38 in TYP (0.96 cm)
3/16 in
(4.76 cm)
(DRILL SIZE #Q)
TYP (4X)
7.38 in
(18.74 cm)
1.19 in
(3.02 cm)
1.12 in
(2.84 cm)
0.10 in
(0.25 cm)
11.19 in
(28.34 cm)
10.99 in
(27.91 cm)
9.38 in
(23.81 cm)
9.70 in
(24.63 cm)
0.17 in
(0.41 cm)
Installation Guide – DOC. 6581A Mud Mount Kits: MMK-8X-DSW & WMKM-8X-DSW 3
Mud Mount Kits Crestron MMK-8X-DSW & WMKM-8X-DSW

Installation

This section provides an installation procedure for each Mud Mount Kit. The “MMK-8X-DSW Procedure” starts below and the “WMKM-8X-DSW Procedure”
starts on page 6. Be sure to review each before starting.

MMK-8X-DSW Procedure

This section provides the necessary steps for assembly of the MMK-8X-DSW for use with either the BB-8X-DSW or PMK-8X-DSW. It is assumed the BB-8X-DSW or PMK-8X-DSW has been secured to the stud according to the instructions in the latest Installation Guides (Doc. 6579 and Doc. 6580 respectively). It is also assumed that drywall is in place and a cutout for the TPMC-8X-DSW and touchpanel is made in the drywall.
Complete the steps in the order provided. The only tools or materials required and not supplied are four standard drywall screws, #2 Phillips screwdriver, a level and tools/material to apply drywall joint compound.
CAUTION: Allow an air gap of at least 12 inches (30.48 cm) in the wall cavity above and below the touchpanel for heat dissipation.
NOTE: The illustrations in this procedure show the installation of the
MMK-8X-DSW with the PMK-8X-DSW. Even though the illustrations only show the PMK-8X-DSW, they are identical for the BB-8X-DSW.
1. Pass a fastener plate through the opening and align its two center holes with the top two pins on the PMK-8X-DSW. Verify that the pins on the fastener plate are not between (facing) the fastener plate and the PMK-8X-DSW. Refer to the following illustration for visual guidance.
Secure Fastener Plates to PMK-8X-DSW (or BB-8X-DSW)
PMK-8X-DSW
PUSH-ON FASTENERS (4) (2004121)
FASTENER PLATES (2) (2004825)
4 Mud Mount Kits: MMK-8X-DSW & WMKM-8X-DSW Installation Guide – DOC. 6581A
Crestron MMK-8X-DSW & WMKM-8X-DSW Mud Mount Kits
2. Slide a push-on fastener over each pin of the PMK-8X-DSW (or BB-8X-DSW) to loosely secure the fastener plate and the mounting plate. Do not push the push-on fasteners all the way down onto the pins. Slide them on enough to keep the fastener plate and mounting plate as one fastener/mounting plate assembly.
3. Use the second fastener plate and repeat steps 1 and 2 using the lower two PMK-8X-DSW (or BB-8X-DSW) pins.
NOTE: When installing into the PMK-8X-DSW, verify that the 18 AWG bus wire securing the cables for the touchpanel remains attached.
4. Insert the symmetrical mud ring plate into the opening, as shown in the
illustration below.
Insert and Secure Mud Ring Plate into PMK-8X-DSW (or BB-8X-DSW)
HOLES FOR DRYWALL SCREWS (NOT INCLUDED). SCREW LENGTH SHOULD NOT EXCEED DRYWALL THICKNESS BY MORE THAN ½ INCH (12.7 MM).
PMK-8X-DSW
DRYWALL
FLANGE
MUD RING PLATE (2017641)
5. When the mud ring plate is in position, bend the top two flanges of the plate upward and the bottom two flanges downward.
If mounting into the PMK-8X-DSW, bend the flanges approximately
90 degrees.
If mounting into the BB-8X-DSW, bend the flanges back as far as they
can go.
6. Use four standard drywall screws (length should not exceed drywall thickness by more than ½ inch) to secure the mud ring plate to the rest of the assembly. The screws pass through the clearance holes in the PMK-8X-DSW (or BB-8X-DSW) and are secured in the extruded holes of the fastener plates.
7. Verify that the mud ring plate is level.
Installation Guide – DOC. 6581A Mud Mount Kits: MMK-8X-DSW & WMKM-8X-DSW 5
Mud Mount Kits Crestron MMK-8X-DSW & WMKM-8X-DSW
NOTE: Do not over tighten screws. Doing so may over-dimple or rip the mud ring plate.
8. Use a #2 Phillips screwdriver and tighten the drywall screws by hand so that they slightly dimple into the holes in the mud ring plate.
9. Apply drywall joint compound as needed to finish the cutout. Avoid covering the four tapped mounting holes.
10. Run the necessary cables for the touchpanel and secure them behind the drywall.
11. When dry, the TPMC-8X-DSW and touchpanel can be installed using the
four #06-32 1 ½” screws included with the TPMC-8X-DSW (two at each
side), as shown in the illustration below. Refer to the latest revision of the TPMC-8X-DSW Installation Guide (Doc. 6588) for installation
instructions.
Touchpanel Mounting Using MMK-8X-DSW – Exploded View
PUSH-ON
FASTENERS (4)
FASTENER PLATES (2)
PMK-8X-DSW
DRYWALL
MUD RING (2017641)
TPMC-8X-DSW (bezel removed)
TPMC-8X-DSW MOUNTING SCREWS (4) #06-32 X 1-½" (2 ON EACH SIDE)
(bezel)

WMKM-8X-DSW Procedure

NOTE: Since the TPMC-8X-DSW contains moving parts, mounting to a stud offers more support and is therefore highly recommended. Although Crestron offers the post-construction WMKM-8X-DSW mounting option, a mounting option that is secured to a stud, such as the BB-8X-DSW or PMK-8X-DSW is highly recommended.
This section provides the necessary steps for assembly and installation of the WMKM-8X-DSW into a wall. Review the procedure and complete the steps in the order provided. The only tools or materials required and not supplied are a drywall saw or equivalent, a level, four standard drywall screws, #2 Phillips screwdriver and tools/materials to apply drywall joint compound.
CAUTION: Allow an air gap of at least 12 inches (30.48 cm) in the wall cavity above and below the touchpanel for heat dissipation.
1. Insert the two pins on one fastener plate into the top two outer holes on the mounting plate, as shown in the illustration on the following page.
6 Mud Mount Kits: MMK-8X-DSW & WMKM-8X-DSW Installation Guide – DOC. 6581A
Crestron MMK-8X-DSW & WMKM-8X-DSW Mud Mount Kits
Create the Fastener/Mounting Plate Assembly
MOUNTING PLATE (2017789)
PUSH-ON FASTENERS (4) (2004121)
FASTENER PLATES (2) (2004825)
2. Slide a push-on fastener over each pin on the fastener plate to loosely secure the fastener plate and the mounting plate. Do not push the push-on fasteners all the way down onto the pins. Slide them on enough to keep the fastener plate and mounting plate as one fastener/mounting plate assembly.
3. Use the second fastener plate and repeat steps 1 and 2 using the lower two pins.
4. Locate an area on the wall that is free of miscellaneous wiring and studs.
5. Make a small hole near the middle of the designated site; verify that the location is suitable.
NOTE: Make the cutout as level as possible. The mounting plate allows for only minor leveling adjustments.
6. Use the template and drywall saw or equivalent to produce a level cutout in the drywall. Refer to illustration on page 3 for exact cutout dimensions.
7. Insert the symmetrical mud ring plate into the opening, as shown in the illustration on the following page.
Installation Guide – DOC. 6581A Mud Mount Kits: MMK-8X-DSW & WMKM-8X-DSW 7
Mud Mount Kits Crestron MMK-8X-DSW & WMKM-8X-DSW
Insert Mud Ring Plate into Opening
IMPORTANT
PLEASE MAKE DRYWALL CUTOUT AS LEVEL AND CLEAN AS POSSIBLE. THE MOUNTING PLATE ALLOWS ONLY MINOR ADJUSTMENTS OF THE TPS-8X-DSW.
FLANGE
MUD RING PLATE (2017641)
HOLES FOR DRYWALL SCREWS (NOT INCLUDED). SCREW LENGTH SHOULD NOT EXCEED DRYWALL THICKNESS BY MORE THAN ½ INCH (12.7 MM).
8. Carefully pass the fastener/mounting plate assembly through the opening and rest the assembly against the interior surface of the drywall. Verify that the fastener plates are between the mounting plate and the drywall.
9. When the fastener/mounting plate assembly is in position, bend the top two flanges of the mud ring upward (approximately 90 degrees) and the bottom two flanges downward (approximately 90 degrees). Refer to the following illustration.
NOTE: Fastener/mounting plate assembly will have a slight play; this is normal. It allows for minor adjustments to the entire assembly during installation.
Bend Flanges
8 Mud Mount Kits: MMK-8X-DSW & WMKM-8X-DSW Installation Guide – DOC. 6581A
Crestron MMK-8X-DSW & WMKM-8X-DSW Mud Mount Kits
10. Use four standard drywall screws (of adequate length) to secure the plate to the fastener/mounting plate assembly. The screws pass through the clearance holes in the plate and are secured in the extruded holes of the fastener plates.
11. Verify that the plate is level before tightening.
NOTE: Do not over tighten screws. Doing so may damage the plate.
12. Use a #2 Phillips screwdriver and tighten the drywall screws by hand so that they slightly dimple into the holes in the mud ring plate.
13. Run the necessary cables for the touchpanel and secure them behind the drywall.
14. Apply drywall joint compound as needed to finish the cutout. Avoid covering the four tapped mounting holes.
12. When the joint compound is dry, the TPMC-8X-DSW and touchpanel can be installed using the four included #06-32 1 ½” screws (two at each side), as shown in the following illustration. Refer to the latest revision of the TPMC-8X-DSW Installation Guide (Doc. 6588) for installation instructions.
Touchpanel Mounting Using WMKM-8X-DSW – Exploded View
PUSH-ON
FASTENERS (4)
MOUNTING PLATE (2017789)
FASTENER PLATES (2)
DRYWALL
MUD RING (2017641)
TPMC-8X-DSW (bezel removed)
TPMC-8X-DSW MOUNTING SCREWS (4) #06-32 X 1-½" (2 ON EACH SIDE)
(bezel)
Installation Guide – DOC. 6581A Mud Mount Kits: MMK-8X-DSW & WMKM-8X-DSW 9
Mud Mount Kits Crestron MMK-8X-DSW & WMKM-8X-DSW

Contact Information and Updates

Further Inquiries

If you cannot locate specific information or have questions after reviewing this guide, please take advantage of Crestron's award winning customer service team by calling the Crestron corporate headquarters at 1-888-CRESTRON [1-888-273-7876]. For assistance in your local time zone, refer to the Crestron website (http://www.crestron.com/offices
You can also log onto the online help section of the Crestron website (http://www.crestron.com/onlinehelp First-time users will need to establish a user account to fully benefit from all available features.
As of the date of manufacture, the MMK-8X-DSW and WMKM-8X-DSW have been tested and found to comply with specifications for CE marking.
) for a listing of Crestron worldwide offices.
) to ask questions about Crestron products.

Future Updates

As Crestron adds improvements to the MMK-8X-DSW and WMKM-8X-DSW, additional information may be made available as manual updates. These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision.
Check the Crestron website periodically for manual update availability and its relevance. Updates are identified as an “Addendum” in the Download column.
10 Mud Mount Kits: MMK-8X-DSW & WMKM-8X-DSW Installation Guide – DOC. 6581A
Crestron MMK-8X-DSW & WMKM-8X-DSW Mud Mount Kits

Return and Warranty Policies

Merchandise Returns / Repair Service

1. No merchandise may be returned for credit, exchange or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact an authorized CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying the nature of the problem, name and phone number of contact person, RMA number and return address.
2. Products may be returned for credit, exchange or service with a CRESTRON Return Merchandise Authorization (RMA) number. Authorized returns must be shipped freight prepaid to CRESTRON, 6 Volvo Drive, Rockleigh, N.J. or its authorized subsidiaries, with RMA number clearly marked on the outside of all cartons. Shipments arriving freight collect or without an RMA number shall be subject to refusal. CRESTRON reserves the right in its sole and absolute discretion to charge a 15% restocking fee plus shipping costs on any products returned with an RMA.
3. Return freight charges following repair of items under warranty shall be paid by CRESTRON, shipping by standard ground carrier. In the event repairs are found to be non-warranty, return freight costs shall be paid by the purchaser.

CRESTRON Limited Warranty

CRESTRON ELECTRONICS, Inc. warrants its products to be free from manufacturing defects in materials and workmanship under normal use for a period of three (3) years from the date of purchase from CRESTRON, with the following exceptions: disk drives and any other moving or rotating mechanical parts, pan/tilt heads and power supplies are covered for a period of one (1) year; touchscreen display and overlay components are covered for 90 days; batteries and incandescent lamps are not covered.
This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer. Purchasers should inquire of the dealer regarding the nature and extent of the dealer's warranty, if any.
CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended or if it has been subjected to misuse, accidental damage, modification or improper installation procedures. Furthermore, this warranty does not cover any product that has had the serial number altered, defaced or removed.
This warranty shall be the sole and exclusive remedy to the original purchaser. In no event shall CRESTRON be liable for incidental or consequential damages of any kind (property or economic damages inclusive) arising from the sale or use of this equipment. CRESTRON is not liable for any claim made by a third party or made by the purchaser for a third party.
CRESTRON shall, at its option, repair or replace any product found defective, without charge for parts or labor. Repaired or replaced equipment and parts supplied under this warranty shall be covered only by the unexpired portion of the warranty.
Except as expressly set forth in this warranty, CRESTRON makes no other warranties, expressed or implied, nor authorizes any other party to offer any warranty, including any implied warranties of merchantability or fitness for a particular purpose. Any implied warranties that may be imposed by law are limited to the terms of this limited warranty. This warranty statement supersedes all previous warranties.
Trademark Information
All brand names, product names and trademarks are the sole property of their respective owners. Windows is a registered trademark of Microsoft Corporation. Windows95/98/Me/XP/Vista and WindowsNT/2000 are trademarks of Microsoft Corporation.
Installation Guide – DOC. 6581A Mud Mount Kits: MMK-8X-DSW & WMKM-8X-DSW 11
Crestron Electronics, Inc. Installation Guide – DOC. 6581A
15 Volvo Drive Rockleigh, NJ 07647 (2017891) Tel: 888.CRESTRON 04.07 Fax: 201.767.7576 Specifications subject to www.crestron.com change without notice.
Loading...