CREEK 5250 & 5250SE SPECIFICATION
|
STANDARD |
SE |
|
|
|
|
|
POWER OUTPUT (both channels) |
50 |
Watts into 8 Ω |
60 Watts |
|
|
|
|
POWER OUTPUT (one channel) |
60 |
Watts into 8 Ω |
70 Watts |
Not recommended for use into more than two pairs of 8 Ω loudspeakers.
OUTPUT CURRENT |
(auto current limited) |
> 20 Amps |
> 25 Amps |
|
|
|
|
|
|
TOTAL HARMONIC DISTORTION |
< 0·05% |
|
< 0.05% |
|
(20 Hz to 20 kHz) |
|
|
|
|
|
|
|
||
FREQUENCY RESPONSE |
3 Hz to 25 kHz - 1 dB |
|
||
|
|
|
|
|
SLEW RATE |
|
> 50 V per μS |
|
|
|
|
|
|
|
INPUT SENSITIVITY |
|
450 mV line input |
470 mV |
|
(with +3dB setting selected on pre-amp) |
|
|
|
|
|
|
|
||
PRE-AMP OUTPUT LEVEL |
600 mV 5 kΩ |
660 mV 5 kΩ |
||
|
|
|
||
SIGNAL TO NOISE RATIO (‘A’ weighted) |
> 105 dB |
|
||
|
|
|
||
SEPARATION (line inputs) |
> 60 dB at 1 kHz |
|
||
|
|
|
|
|
MM PHONO SENSITIVITY AND IMPEDANCE |
3.5 mV |
47 kΩ |
(when fitted) |
|
|
|
|
|
|
MC PHONO SENSITIVITY AND IMPEDANCE |
0.75 mV |
1 kΩ |
(when fitted) |
|
|
|
|
|
|
POWER CONSUMPTION (at idle) |
45 W |
|
65 W |
|
|
|
|
|
|
POWER CONSUMPTION (full power 10% THD) |
260 W |
|
340 W |
|
|
|
|
|
|
WEIGHT |
|
7kgs, 15.5lbs |
|
|
|
|
|
|
|
SIZE |
|
420 x 60 x 280 mm, |
|
|
|
|
|
|
|
|
|
16·5” x 2·4” x 11'' |
|
|
|
|
|
||
MAINS VOLTAGE |
@ 60Hz |
100V Japan, 115V North America |
||
|
|
|
||
|
@ 50Hz |
230/240V Europe, Asia and UK |
MAINS VOLTAGE AND FREQUENCY IS INTERNALLY SET FOR THE COUNTRY OF USE
Creek Audio Ltd reserve the right to change or modify the specification of its products without prior warning.
Designed and made in the UK.
Creek Audio Ltd
2 Bellevue Road, Friern Barnet, London N11 3ER, England
Tel: 00 44 + (0)181-361 4133 |
Fax: 00 44 + (0)181-361 4136 |
E-mail: mcreek@ibm.net |
Internet: www.creekaudio.co.uk |
Creek 5250
& 5250SE
Operating Instructions
Thank you for purchasing the 5250 amplifier. You are now in possession of a State of the Art Integrated Amplifier. The functions and operation of the 5250 and Special Edition are exactly the same and are very simple. However, the following notes are provided to explain all aspects of its design and use.
MAINS CONNECTION
When unpacking the amplifier please keep the packing material in a safe place for possible future use. In the pack there is a separate mains cable suitable for connecting to the mains supply in the country of use. The IEC socket end of the cable should be firmly inserted into the connector on the rear panel marked "Mains Input".
Remember, do not overload the mains wall socket with too many plugs or adaptors. The high quality performance of the amplifier will be impaired if the electrical supply to it is in poor condition. If in doubt, consult a qualified electrician or your dealer.
The "Mains Input" connection is also fitted with a fuse, specifically suited to the supply voltage of the country of use. The correct value is clearly marked on the rear panel next to the Mains Input.
Should it be necessary to replace the fuse, ensure that you use the same type as specified on the rear panel, i.e.
5 x 20mm cartridge type: T 3.15 A surge resisting for 220-240V 50Hz AC, T 6.3 A surge resisting for 110120V 60Hz AC or an T 8A surge resisting for 100V (Japan).