Craftsman 390304612, 390304552 Owner’s Manual

SEARS
OWNER'S
MANUAL
MODELNO.
390.304552
390.304612
390.304692
Model No. 390.304552
CAUTION:
Read and Follow
All Safety Rulesand Operating Instructions
Before FirstUse of
ThisProduct.
Save ThisManual For FutureReference.
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
Model No. 390.304612 Model No. 390.304692
I:RRFTSMRN°
SUBMERSIBLE
SUMP PUMP
Safety Instructions
Installation
Electrical
Service
Repair Parts
PRINTED IN U.S.A. Form NO. F642-9811 (Rev, 10/22/02)
CONTENTS
INTRODUCTION
1NTROI)I It 2Tl( )N/\\ ,\ RRA NIS .................. 2
SAFH'V . ...................................... 2
INSTALLATION ........................... 3
H.ECFRICAI ............................... i
St:RVICIi .............................................. 5
PARTS ........................................................ (_7
FULL ONE YEAR WARRANTY ON CRAFTSMAN ®SUBMERSIBLE SUMP PUMPS
For one year from the date of purchase, Sears will repair or replace this pump, free of charge, if defective ha material or
workmanship.
Plcasc rczld otlr ill_,trtlctiolls bcl_.)rc yotl install and list VOllr
no\\ pttmp; this ",','ill help yotl obtain flail valuc and gooti scr
vitc lronl it It will als(i help y(lu avoid needless service costs thai rt'suh Irom C;lUSeS We CallnOl COlttrol ;llld cautlol cover
in O111" %varrallt)
LIMITED WARRANTY ON CRAFTSMAN* 1/3-HP SUBMERSIBLE SUMP PUMPS
After one year and through two years from the date of purchase, Sears will furnish, free of charge, a replacement pgrt for 7any defective part. YOUpay for labor.
This warranty does not cover repairs or replacement parts necessary because of abuse or negligence including failure to install, adjust
and operate this pump according to the instructionsin the owner's manual.
SEARS WILL NOT BE LIABLE FOR LOSS OR DAMAGE TO PROPERTY OR ANY INCIDENTAL oR CONSEQUENTIAL LOSS OR
DIPENSE FROM PROPERTY DAMAGE DUE DIRECTLy OR INDIRECTLY FROM THE USE OF _ PRODUCT .....
Some states do not allow the exclusion or limitation Of incidental or consequential damages, so the above _tation or exclusion may n0t_apply to you.
WARRANTY SERVICE IS AVAILABLE BY SIMPLY CONTACTING THE NEAREST SEARS SERVICE CENTER/DEPARTMENT IN THE UNITED STATES. :
Tlfis warranty applies only whife the product is in use in the UMt_ Sta_ _ This warranty gives you specific iegal rights and you mayalso!ia, de0flfe/figlxswhichvary_m state to state.
Sears, Roebuck and Co., De]p_ 817 '¢gA, HO_ _es, IL 60179
LIMITATION OF LIABILITY
RULES FOR SAFE INSTALLATION AND OPERATION
Carefully read and follow all safety instructions in this manual or on pump.
_This is the safety, alert symbol. When you see this sym-
bol on your pump or in this manual, h)ok for one of the
following signal words and he alert to the potemial for personal injury!
I warns about hazards that will cause serious per-
sonal injury, death or major property damage ff ignored.
[ _.WARNING ]warns about hazards that will or can cause seri-
ous personal injury, death or major property damage if ignored.
& cAuTioN-,: warnsL. _ - " about hazards that will or can cause
minor personal injury or property damage if ignored. The word NOTICE indicates special instructions which are im-
portant but not related to hazards.
Electrically powered stamp pumps normally give many years of trouble-free service when correctly installed, maintained, and used. However, unusual circumstances (interruption of power
to the pump, dirt/debris in the sump, flooding that exceeds the pump's capacity, electrical or mechanical failure in the pump,
etc.) may prevent your pump from functioning normally. To pre vent possible water damage due to flooding, consult your local
Sears store about installing a secondary sump pump or a DC backup sump pump See "Service", Page 5, for information
about common sump pump problems and remedies.
1. To avoid risk nf serious bodily injury and property damage, read safety instructions carefully before installing pump.
2. Follow local and/or national plumbing and electrical codes
when installing pump
3. _*v_nn._uj TO avoid fatal shocks, proceed as follows if pump needs servicing:
&Disconnect power to pump outlet box before
pulling pump cord plug. After plug is pulled, let pump cool for 20 minutes before attempting to work on it.
Modem motors are designed to operate at high tempera- tures.
B. Take extreme care when changing fuses. To reduce
the chance of fatal electrical shocks, DO NOT stand in water or put your finger in the fuse socket.
C. Ground the electrical outlet box. D. Use only an individual branch circuit with a Ground
Fault Circuit Interrupter (GFCI) protected grounded outlet for cord plug.
4. Never run pump dry. To do so can damage internal parts, overheat the pump (which can cause burns to people han- dling or servicing the pump), and will void the warranty!
5. DO NOT attempt to oil the pump motor. A special oil has
been put into the motor housing at the factory; use of any other oil will void the warranty and could damage the pump.
6. This pump is recommended for use in permanent installa-
tions only. Pump water only with this pump.
ADDITIONAL INSTALLATION HATERIALS
Sump/Utility Pump Hose Kit, SEARS Stock No. 27909, con- taining 24' (7.3M) of 1-1/4" flexible plastic pipe, a 1-1/4" plas-
tic adapter and a stainless steel clamp. Check Valve, SEARS Stock No. 2789.
INSTALLATION
THE SUMP
The sump should be located at the lowest place in the base-
ment or area to be drained. Floor drains from other areas in the basement may be tiled into the sump. Drain tile around a house foundation can also be tiled into the sump, effec-
tively removing water and relieving pressure frorn this area.
A suitable sump can be a 20" or 24" (500_10mm) sewer tile.
The minimum size is 12" (305mm) in diameter for Models
390.304552 and 390.304612; 10" (254mm) for Model
390.304692.
A sump cover is desirable to exclude refuse from the sump.
Consult local code for sump cover specifications. NOTICE: Periodically inspect pump, system components,
and sump for debris and foreign objects. Keep sump free of all refuse. Perform routine maintenance as required.
PUMP INSTALLATION
Set the pump on the bottom of the sump, making sure that is sits solidly and is level. Be sure there is enough space around the pump to allow the switch free movement as the sump water level changes. Pump should not be installed on
clay, earth, or sand surfaces.
[& CAUTION}Risk of flooding. If a flexible discharge hose
is used, pump may move around in sump when motor starts. If it moves far enough so that the switch hits the side of the
sump, the switch may stick and prevent pump from starting. Make sure that pump is secured so that it cannot walk
around in sump. Hose Kit No. 27909 includes 1-1/4" flexible plastic pipe for
the discharge pipe. Run discharge pipe to the nearest sewer outlet or other point of disposal. Use the most direct route and the fewest turns and elbows possible. Make sure that pump cannot move around in sump pit.
Use teflon tape to seal threads in plastic pipe. Hand tighten only.
NOTE: To avoid backflow into sump when pump shuts off, install a Check Valve, SEARS Stock No. 2789, in threaded dis- charge port of pump. Be sure arrow on check valve body points away from the pump. This Sears check valve is equipped with an air bleed hole to prevent airlocking pump. If using any other check valve, drill 1/8" (3.2mm) hole in dishcharge pipe just above pump body but below check valve to prevent air locks.
<t----- 20" to 24" Sump_Cover
500 to 610rnm) 1/4' (6ram) \ Basement Floor
FLOAT SWITCH INSTALLATION AND OPERATION
(Models 390.304552 and 390.304612;
For Model 390.304692, see Page 7)
The automatic float switch is factory mounted on the pump and preset for a pumping range of approximately 7". Tether
length is factory preset at 3-1/2" (89mm) (see Figure 3). Do not change tether length.
Be sure automatic float can swing freely through its entire arc without interference from pump, piping, sump wall or
any other object.
When sump is dry, the watertight automatic float switch is
hanging in a downward position and the pump is off.
As water comes into the sump, the automatic float switch
rises to an upward position and the pump starts. Water will continue to be pumped until the float switch is
hanging in the downward position again, when pump will stop.
IAWARNING]Risk of electric shock. Before installation,
check your local electrical codes. To avoid personal injury when servicing your pump, be sure that the power is dis- connected from both the pump and the float switch.
To check operation, fill sump with water and observe oper- ation through one complete cycle.
Grounded Electrical
Make sure pump cannot
move fn sump
FIGURE 2 - Models 390.304552 and 390.304612
20" I
(500 to 610ram)
FIGURE I
Sewer Tile
(st
(89mm)
FIGURE 3 - Tether Length
DO NOT ALLOW PUMP TO RUN DRY
Pump should not be allowed to run dry prior to shutting off. To do so voids the warranty and could ruin the pump.
Loading...