Craftsman 1256177288, 12538909, VJC809SC Owner’s Manual

Operator's Manual
8 Gallon Wet/Dry Vacuum
Model No. 125.389___p
Safety
CAUTION: Before using this
product, read this manual and follow all its Safety Rules and Operating instructions.
Sears Brands Management Corporation, Hoffman Estates, IL 60179 U.S.A
WWW. crafts man. COrn
Operation
Maintenance
Parts
Espa_ol =p_gina 16
Warranty
CRAFTSMAN ONE YEAR FULL WARRANTY
FOR ONE YEAR from the date of purchase, this product is warranted against defects in material or workmanship. A defective product will be replaced free of
charge. For warranty coverage details to obtain free replacement, visit the web page:
www. craftsman.com/warranty This warranty does not cover bags, filters, hose or attachments, which are expendable parts that can wear outfrom normal use within the warranty period.
This ONE YEAR warranty is void if this product is ever used while providing commercial services or if rented to another person. For 90 DAY commercial and rental use terms, seethe Craftsman warranty web page. Thiswarranty gives you specific legal rights, and you may also have other rights
which vary from state to state.
Sears Brands Management Corporation, Hoffman Estates, JL60179
iMPORTANTSAFETY
READ AND UNDERSTAND ALL
iNSTRUCTiONS BEFORE USING THiS VACUUM
Read and understand this operator's
manual and all labels on the Wet/Dry Vacuum cleaner before operating. Safety is a combination of common sense, staying alert and knowing how your vacuum works.
Use this Wet/Dry Vac only as described in this manual. To reduce the risk of personal
injury or damage to your Wet/Dry Vac, use only Craftsman recommended accessories.
Household Type
SAVETHiSMANUAL
FOR FUTURE REFERENCE.
When using an electrical appliance,
basic precautions should always be followed including the following:
WARI!IING: o
THE RISK OF FIRE, ELECTRIC
SHOCK OR iNJURY:
, Do not run vac unattended.
Do not vacuum, or use this Wet/Dry Vac near flammable liquids, gases, orexplosive vapors like gasoline or other fuels, lighter fluids, cleaners, oil-based paints, natural gas, hydrogen, or explosive dusts like coal dust, magnesium dust, grain dust, or gun power. Sparks inside the
iNSTRUCTiONS
motor can ignite flammable vapors or dust.
* Do not vacuum anything that is burning
or smoking, such as cigarettes, matches, or hot ashes.
* Keep cord away from heated surfaces. * Do not expose to rain. Store indoors.
, Do not unplug by pulling on cord. To
unplug, grasp the plug, not the cord.
* Do not use with damaged cord, plug or
other parts.
* If vac is not working as it should, has
been dropped, damaged, left outdoors, or dropped into water, take it to a service dealer for inspection and repair before using it again.
, Do not pull or carry by cord, use cord as
handle, close a door on cord, or pull
cord around sharp edges or corners. , Do not run Wet/Dry Vac over cord. * Do not handle plug or the Wet/Dry Vac
with wet hands. * To reduce the risk of health hazards
from vapors or dusts, do not vacuum
toxic materials. * Do not store near hazardous materials.
* Do not use this Wet/Dry Vac with a torn
filter or without the filter installed except
when vacuuming liquids as described in
the operation section of this manual. * Do not allow to be used as a toy. Close
attention is necessary when used by or
near children. *To reduce the risk of injury from accidental
starting,unplugpowercordbefore
changingorcleaningfilter.
DonotleaveWet/DryVacunattended whenpluggedin.Unplugfromoutlet whennotinuseandbeforeservicing.
TurnoffWet/DryVacbeforeunplugging.
Donotputanyobjectintoventilation openings.Donotvacuumwithany ventilationopeningsblocked;keepfree ofdust,lint,hairoranythingthatmay
reduceairflow.
Keephair,looseclothing,fingers,and allpartsofbodyawayfromopenings andmovingparts.
Toreducetheriskoffalls,useextra carewhencleaningonstairs.
When using as blower:
Direct air discharge only at work area.
Do not use Wet/Dry Vac as a sprayer.
Do not direct air at bystanders.
Keep children away when blowing.
Wear safety goggles.
Polarized Plug
To reduce the risk of electrical shock, this appliance has a polarized plug (one with
the blade wider than the other). This plug will fit in a polarized outlet only one way.
If the plug does not fit fully in the outlet,
reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in
any way. Double insulation [] eliminates the need for the three wire gro_unded
power cord and grounded power supply system.
Observe the followingwarnings that appear on the motorhousing of your Vac:
GROUNDING NOT REQUIRED.
'_ OUBLE INSULATED
WHEN SERVICING USE ONLY IDENTICAL REPLACEMENT PARTS.
A WARNING
= For your own safety, read and
understand owner's manual.
oDo not allow unit to be in operation if
unattended.
Do not pick up hot ashes, coals,
toxic, flammable or other hazardous
materials.
, Do not use around explosive liquids
_or vapors, j
WARNING: To reduce the risk of
electric shock =do not expose to rain = store indoors.
,_, WARNING: When using as a blower:
Wear safety goggles labeled "ANSI Z87.1" (Canada CSA Z94.3) on the package. Turn unit off before setting on ground or releasing grasp of handle.
Electric shock could occur if used on
wet surfaces. Direct tool discharge only
at work area. Do not direct discharge at bystanders. Keep children away.
Extension Cords
When using an extension cord with your VVet/Dry Vac refer to the following table to determine the required A.W.G. (American Wire Gauge) wire size. Before using
Wet/Dry Vac, make sure it is in good working condition, including power cord.
Also, make sure extension cord is in good working condition prior to use. Make
repairs or replacements before using the vacuum cleaner. Only use extension cords that are rated for outdoor use.
Length of Extension Cord
110V-120V
Amps A.W.G Wire Size
0-6 18 16 16 14
7-10 18 16 14 12 11-12 16 16 14 12 13-16 14 12 Not recommended
25 Feet 50 Feet 100 Feet 150 Feet
7.5 Meters 15.25 Meters 30.5 Meters 45.7 Meters
Introduction
This Wet/Dry Vac is intended for vacuuming wet and dry materials and may be used as a blower.
Table of Contents
Section Page
Warranty ................................................. 2
important Safety instructions ........... 2
Polarized Plug .................................... 3
Extension Cords ..................................... 3
introduction ............................................ 4
Table of Contents ................................... 4
Assembly ................................................ 5
Carton Contents List ......................... 5
Unpacking Your Wet/Dry Vacuum
& General Assembly .......................... 6
Operation ................................................ 7
Vacuuming Dry Materials .................. 7
Vacuuming Liquids ............................ 8
Blowing Feature ................................. 9
Read this operator's manual to familiarize yourself with the product features and to understand the specific usage of your new Wet/Dry Vac.
Section Page
Maintenance ......................................... 10
Emptying the Collection Tank ........ 10
Installing & Cleaning
the Supplied Cartridge Filter .......... 10
installing A Replacement
Cartridge Filter ................................ 11
Installing & Cleaning
Foam Sleeve Filter .......................... 12
Cleaning & Disinfecting
the Wet/Dry Vac .............................. 12
Storage ............................................. 12
Troubleshooting .................................... 13
Repair Parts ........................................... 14
Assembly
Remove entire contents of carton and
check for parts inside the collection tank. Check each item against the Carton Contents List. If any parts are missing or damaged please call 1-800-469-4663 for replacement.
B C
Carton Content List
Key
Description ................................. Qty.
A
Vac Assembly ................................. 1
B
Handle and Caster Assembly
Screws ........................................... 6
C
Caster Feet Assemblies ................. 4
D
Floor Squeegee Nozzle.................. 1
E
2-1n-1 Utility Nozzle........................ 1
F
Foam Sleeve Filter ......................... 1
G
Handle ............................................ 1
H
Cartridge Filter ............................... 1
I
Hose Assembly .............................. 1
J
Extension Wand ............................. 2
K
Operator's Manual.......................... 1
Power Head
Vacuum Port
I
H
Handle
On/Off Switch
_ Latch
Collection Tank
Drain
Assemblies
Assembly (continued)
A Phillps head screw driver is required.
,_, WARNING: Do not plug in power
cord to power outlet, make sure plug is disconnected before assembling the wet/dry vac.
UNPACKING YOUR WET/DRY VACUUM & GENERAL ASSEMBLY
1. Ensure that the power cord is
disconnected from the power outlet. (Fig. 1)
2. Undo the latches. (Fig. 2)
3. Lift the top section off the tank.
(Fig. 3)
4. Remove the contents from inside the
collection tank, make sure you have all contents as listed on carton
content list on page 5. (Fig. 4)
5. Turn the tank upside down, and
insert the casters on to the four feet of the tank. Ensure that they are
mounted correctly. Do not over tighten. (Fig. 5)
6. insert the handle into the slots on
the power head and pressure into place.(Fig. 6)
7. For dry vacuum cleaning, install the supplied cartridge filter. (Fig.7)
8. For wet vacuum cleaning, install the supplied foam filter. (Fig. 8)
9. Replace the top section on the tank. (Fig. 9)
10. Align the top section with the clasps and snap into place by applying pressure until clasps click. (Fig. 9)
11. insert the large end of the hose into the front inlet of the tank and
turn to lock,Fit the required accessory on to the suction tube. (Fig.10 & Fig.11)
12. After vac use, store hose, accessories and cord as illustrated
on page 12.
Operation
Vacuuming Dry Materials
,_ WARNING: Be sure to read, understand and apply all the information in the
important Safety instructions section at the beginning of this operator's manual. Do not vacuum in areas with flammable gases, vapors, or explosive dusts in the air. Flammable gases or vapors include but are not limited to: lighter fluid, solvent type cleaners, oil-base paints, gasoline, alcohol or aerosol sprays. Explosive dusts include but are not limited to: coal, magnesium, grain or gun powder. To reduce the risk of health hazards from vapors or dust, do not
vacuum toxic materials.
1. Ensure that the power cord is disconnected from the outlet. (Fig. 1)
2. For dry vacuuming, the cartridge filter must be installed correctly. To verify,
please refer to Installing Cartridge Filter on page 10.
3. Ensure that the cartridge filter is completely mounted. Ensure that the
filter is inserted all the way. (Fig. 2, Fig. 3)
4. Replace the top section on the tank, and secure it in place using the clasps.
(Fig.4)
5. insert the larger end of the hose into the front inlet on the tank and lock it in
place. Push the required attachment on to the free end of the hose or extension.
(Fig. 5)
6. Plug the power cord in to the power outlet. (Fig. 6)
7. Turn the motor on by flipping the switch to the 'l' position. (Fig. 7)
O = OFF I = ON
8.
Once you have completed vacuuming, flip the switch to the '0' position and unplug the power cord from the power outlet.
DO NOT USE THE CARTRIDGE FILTER FOR LiQUiD VACUUMING.
CAUTION: Do not vacuum drywall dust, fireplace soot or ash with standard
Wet/Dry filter. This is very fine dust which will not be captured by the filter
and may cause damage to motor. To purchase the fine dust filter, call
1-800-469-4663 or visit a Sears store.
Operation (continued)
Vacuuming Liquids
,_ WARNING: Be sure to read, understand and apply all the information in the
important Safety instructions section at the beginning of this operator's manual.
Do not vacuum in areas with flammable gases, vapors, or explosive dusts in the air. Flammable gases or vapors include but are not limited to: lighter fluid, solvent type cleaners, oil=base paints, gasoline, alcohol or aerosol sprays.
Explosive dusts include but are not limited to: coal, magnesium, grain or gun
powder. To reduce the risk of health hazards from vapors or dust, do not vacuum toxic materials.
WARNING: Do not plug in power cord to power outlet, make sure plug is disconnected before assembling the Wet/Dry Vac.
7. After use, empty the collection tank by unscrewing the drain cap and drain liquids into suitable receptacle or drain. (Fig. 6, Fig. 7) Remember to refit
the drain cap to the tank after draining.
MPORTANT! When vacuuming large
1. Verify that the power cord is disconnected from the outlet. (Fig. 1)
2. Remove cartridge filter as shown in
Removing and Cleaning Cartridge Filter on page 10. Then install the
foam sleeve filter as shown in
Installing Foam Sleeve Filter on page 12 and secure power head back on
the collection tank. (Fig. 2)
DO NOT USE THE CARTRIDGE FILTER FOR LIQUID VACUUMING.
3. Fit the desired nozzle to the vacuum
hose. (Fig. 3)
4. Verify that the power switch is in the 'O'
OFF position before plugging the power cord into the outlet. (Fig. 4)
5. Turn the motor on by pressing the switch to the '1' ON position. (Fig. 5)
6. Once you have completed vacuuming, press the power switch to the 'O' (OFF)
position and unplug the power cord
from the outlet.
quantities of liquids, do not immerse the nozzle completely in the liquid; leave a
gap at the tip of the nozzle opening to allow air inflow. The machine is fitted with
afloat valve that stops the suction action when the collection tank reaches its
maximum capacity. You will notice an increase in motor speed. When this happens, turn off the machine, disconnect from power supply, and drain
the liquid into a suitable receptacle or
drain. To continue vacuuming, refit the collection tank with the drain cap. After wet vacuuming, turn the machine off and remove plug from power supply. Empty
the collection tank, clean and dry the
inside and outside before storage. REMEMBER! The foam filter must be
removed after wet vacuuming and a cartridge filter must be installed before
dry vacuuming again.
Operation (continued)
Blowing Feature
WARNING:
Always wear safety goggles complying with ANSi Z87.1 (or in
Canada, CSA Z94.3) before using blower.
WARNING:
WARNING:
This Wet/Dry Vac has blowing capabilities. Touse the blower feature follow the
instructionslisted.
1. Make sure the collection tank is empty before using as a blower.
2. Remove hose from the vacuum port.
3. insertthe large end of the hose intothe blower connection in the top of the motor housing. (Fig. 1)
4. Fit the desired attachment to the hose. (Fig. 2)
6. Ensurethe power switch is turned off and plug inthe power supply. (Fig. 3,)
7. Turnthe motor on by flipping the switch
to the "r' position (Fig. 4)
8. The unit will now blow through the
vacuum hose and can be used to clear
obstructions within the hose. (Fig. 5)
Keep bystanders clear from blowing debris.
Wear a dust mask if blowing creates dust that might be inhaled.