Modular Cables
DescriptionCable CountConnector Count (Total)GaugeIn Cable Capacitors
ATX connector 20+4 pin (600mm)1116-22AWGYes
4+4 pin EPS12V (650mm)2216AWGYes
6+2 pin PCIe (650mm)6616-18AWGYes
6+2 pin PCIe (680mm+100mm)2416-18AWGYes
SATA (450mm+110mm+110mm+110mm)31218AWGNo
SATA (550mm+110mm)2418AWGNo
4-pin Molex (450mm+100mm+100mm)3918AWGNo
FDD Adapter (+105mm)2220AWGNo
USB Mini to Motherboard Header Cable (+800mm)1124-28AWGNo
AC Power Cord (1400mm) - C19 coupler1114AWG-
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 1/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 2
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Corsair AX1600i (Sample #3)
RESULTS
Temperature Range (°C /°F)30-32 / 86-89.6
ErP Lot 3/6 Ready✓
(EU) No 617/2013 Compliance✓
115V
Average Efficiency92.221%
Efficiency With 10W (≤500W) or 2% (>500W)78.233
Average Efficiency 5VSB81.807%
Standby Power Consumption (W)0.0457394
Average PF0.992
Avg Noise Output25.60 dB(A)
Efficiency Rating (ETA)ETA-A+
Noise Rating (LAMBDA)LAMBDA-A-
230V
Average Efficiency93.812%
Average Efficiency 5VSB80.799%
Standby Power Consumption (W)0.0744520
Average PF0.988
Avg Noise Output25.51 dB(A)
Efficiency Rating (ETA)ETA-A+
Noise Rating (LAMBDA)LAMBDA-A-
TEST EQUIPMENT
Chroma 63601-5 x4
Electronic Loads
AC SourcesChroma 6530, Keysight AC6804B
Power AnalyzersN4L PPA1530 x2
Sound AnalyzerBruel & Kjaer 2270 G4
MicrophoneBruel & Kjaer Type 4955-A
Data LoggersPicoscope TC-08 x2, Labjack U3-HV x2
TachometerUNI-T UT372 x2
Digital MultimeterKeysight U1273AX, Fluke 289, Keithley 2015 - THD
UPSCyberPower OLS3000E 3kVA x2
Transformer3kVA x2
Chroma 63600-2 x2
63640-80-80 x20
63610-80-20 x2
HOLD-UP TIME & POWER OK SIGNAL (230V)
Hold-Up Time (ms)26.7
AC Loss to PWR_OK Hold Up Time (ms)24.5
PWR_OK Inactive to DC Loss Delay (ms)2.2
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 2/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 3
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
EFFICIENCY UNDER HIGH AMBIENT TEMPERATURE
Corsair AX1600i (Sample #3)
INFO
The PSU`s efficiency under high ambient
temperatures with 115V and 230V input. For this
graph the results of the 10-110% load regulation
table are used
5VSB EFFICIENCY
INFO
This graph depicts the efficiency levels of the 5VSB
rail with 115V and 230V input
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 3/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 4
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Corsair AX1600i (Sample #3)
5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC)
Test #5VSBDC/AC (Watts)EfficiencyPF/AC Volts
1
2
3
4
5
6
0.045A0.227
72.063%
5.037V0.315115.14V
0.090A0.453
76.780%
5.036V0.590115.14V
0.550A2.767
80.883%
5.029V3.421115.15V
1.000A5.025
82.634%
5.024V6.081115.14V
1.500A7.527
82.988%
5.017V9.070115.14V
3.000A14.993
82.019%
4.997V18.280115.13V
0.019
0.035
0.187
0.295
0.380
0.513
5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC)
Test #5VSBDC/AC (Watts)EfficiencyPF/AC Volts
1
2
3
4
5
6
0.045A0.227
64.857%
5.037V0.350230.20V
0.090A0.453
72.134%
5.036V0.628230.20V
0.550A2.766
79.620%
5.030V3.474230.17V
1.000A5.025
80.003%
5.024V6.281230.18V
1.500A7.527
81.532%
5.018V9.232230.19V
3.000A14.994
82.475%
4.998V18.180230.19V
0.007
0.011
0.062
0.109
0.156
0.270
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 4/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 5
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Corsair AX1600i (Sample #3)
115V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 5/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 6
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
EFFICIENCY GRAPH 115V
Corsair AX1600i (Sample #3)
INFO
This graph depicts the PSU’s efficiency throughout
its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations
NOISE GRAPH 115V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
INFO
The PSU’s noise in its entire operational range and
under 30-32 °C ambient is depicted in this graph.
The X axis represents the load on the +12V rail(s)
while the Y axis is the load on the minor rails
PAGE 6/15
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 7
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
VAMPIRE POWER -115V
Corsair AX1600i (Sample #3)
INFO
This graph is generated by the PPA Standby Power
Analysis software which takes full control of the
power analyzer during the whole procedure. This
application features all of the EN50564 &
IEC62301 test limits for standby power software
testing
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 7/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 8
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
10-110% LOAD TESTS 115V
Test #12V5V3.3V5VSB
11.512A2.009A1.999A1.006A160.007
1
12.022V4.979V3.304V4.971V173.19840.12°C115.12V
24.056A3.014A2.998A1.208A320.053
2
12.020V4.976V3.303V4.967V339.51540.51°C115.13V
36.887A3.518A3.498A1.411A479.326
3
12.017V4.974V3.303V4.963V507.37441.64°C115.11V
49.820A4.024A3.996A1.613A639.740
4
12.014V4.972V3.302V4.960V679.58442.35°C115.10V
62.399A5.028A4.999A1.816A799.905
5
12.010V4.970V3.301V4.957V853.13048.15°C115.11V
DC/AC
(Watts)
Corsair AX1600i (Sample #3)
Fan
Efficiency
92.384%0<6.0
94.268%0<6.0
94.472%0<6.0
94.137%0<6.0
93.761%5629.7
Speed
(RPM)
PSU Noise
(dB[A])
Temps
(In/Out)
44.23°C0.958
45.03°C0.989
46.51°C0.995
47.58°C0.997
42.43°C0.998
PF/AC
Volts
6
7
8
9
10
11
CL1
CL2
74.973A6.041A6.003A2.000A959.916
93.311%65113.5
12.007V4.967V3.299V4.953V1028.72949.14°C115.10V
87.525A7.054A7.005A2.223A1119.780
92.742%74117.0
12.004V4.965V3.298V4.950V1207.41150.57°C115.10V
100.151A8.002A8.011A2.427A1280.026
92.079%87622.9
12.001V4.962V3.296V4.946V1390.13351.61°C115.11V
113.115A8.572A8.496A2.428A1439.652
91.359%145838.5
11.998V4.958V3.295V4.944V1575.81253.29°C115.11V
125.919A9.084A9.016A3.041A1600.112
90.579%180044.4
11.995V4.955V3.294V4.934V1766.52954.87°C115.13V
139.297A9.090A9.019A3.043A1760.167
89.816%192244.4
11.992V4.952V3.293V4.931V1959.73756.40°C115.14V
0.116A22.001A22.002A0.000A183.588
87.948%85722.3
12.023V4.984V3.297V5.014V208.74648.85°C115.15V
133.373A1.000A0.999A1.000A1613.019
90.766%175143.8
11.995V4.959V3.298V4.956V1777.12454.46°C115.13V
42.65°C0.999
43.56°C0.998
44.11°C0.998
45.10°C0.999
45.80°C0.999
46.52°C0.996
41.96°C0.972
45.87°C0.999
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 9/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 10
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Corsair AX1600i (Sample #3)
230V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 10/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 11
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
EFFICIENCY GRAPH 230V
Corsair AX1600i (Sample #3)
INFO
This graph depicts the PSU’s efficiency throughout
its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations
NOISE GRAPH 230V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
INFO
The PSU’s noise in its entire operational range and
under 30-32 °C ambient is depicted in this graph.
The X axis represents the load on the +12V rail(s)
while the Y axis is the load on the minor rails
PAGE 11/15
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 12
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
VAMPIRE POWER -230V
Corsair AX1600i (Sample #3)
INFO
This graph is generated by the PPA Standby Power
Analysis software which takes full control of the
power analyzer during the whole procedure. This
application features all of the EN50564 &
IEC62301 test limits for standby power software
testing
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 12/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 13
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
10-110% LOAD TESTS 230V
Test #12V5V3.3V5VSB
11.509A2.007A1.998A1.006A159.964
1
12.023V4.979V3.303V4.970V171.36140.21°C230.17V
24.051A3.015A2.998A1.208A319.998
2
12.020V4.976V3.303V4.967V336.25740.46°C230.19V
36.872A3.519A3.498A1.411A479.145
3
12.017V4.973V3.302V4.963V500.42941.44°C230.20V
49.807A4.024A3.999A1.614A639.589
4
12.014V4.971V3.301V4.959V669.99141.53°C230.20V
62.381A5.032A5.000A1.817A799.772
5
12.011V4.969V3.301V4.956V839.02148.57°C230.21V
DC/AC
(Watts)
Corsair AX1600i (Sample #3)
Fan
Efficiency
93.349%0<6.0
95.165%0<6.0
95.747%0<6.0
95.462%0<6.0
95.322%5719.8
Speed
(RPM)
PSU Noise
(dB[A])
Temps
(In/Out)
44.27°C0.960
45.15°C0.985
46.64°C0.994
47.50°C0.993
42.05°C0.997
PF/AC
Volts
6
7
8
9
10
11
CL1
CL2
74.962A6.042A6.001A2.000A959.776
95.202%64913.5
12.007V4.966V3.299V4.953V1008.14949.50°C230.22V
87.516A7.057A7.005A2.223A1119.677
94.969%75217.7
12.004V4.964V3.298V4.949V1178.98950.88°C230.23V
100.146A8.001A8.012A2.427A1279.946
94.648%86922.8
12.001V4.961V3.295V4.945V1352.31851.87°C230.24V
113.108A8.575A8.497A2.428A1439.576
94.260%132535.7
11.998V4.957V3.295V4.943V1527.23953.51°C230.24V
125.922A9.085A9.017A3.042A1600.024
93.808%176944.0
11.994V4.954V3.294V4.933V1705.63554.54°C230.25V
139.293A9.091A9.019A3.043A1760.112
93.477%192644.4
11.992V4.951V3.293V4.930V1882.94256.70°C230.27V
0.118A22.001A21.997A0.000A183.552
88.815%84921.9
12.023V4.982V3.297V5.013V206.66849.05°C230.29V
133.357A1.000A1.000A1.000A1612.923
93.997%163841.4
11.995V4.957V3.297V4.953V1715.93854.08°C230.27V
42.54°C0.998
43.47°C0.997
43.89°C0.998
44.67°C0.998
45.13°C0.999
46.78°C0.999
42.88°C0.967
45.02°C0.999
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 14/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 15
EFFICIENCY AND NOISE
Top side
Power specifications label
LEVEL CERTIFICATIONS
Anex
Corsair AX1600i (Sample #3)
CERTIFICATIONS 115V
CERTIFICATIONS 230V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 15/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.