Installation Instructions for DF/ED250PRO Field Kit
INSTALLATION INSTRUCTIONS
DF/ED250PRO F IELD KIT (P/N 629087544)
Installation of Low CO2 Indicator Light
Parts List
Item No. Part Number Description Qty.
1 620313223 CO2 Pressure Switch 1
2 77060500 Tee 1/4MFL 1
3 40502 O-Clamp 2
4 77010400 1/4 Barb Stem 2
5 77045700 1/4 Flare Swivel Nut 2
6 178025100 1/4 Flare Washer 3
7 33666 Indicator Light 24V 1
8 620316401 CO2 Light Harness 1
9 620316402 CO2 Pressure Switch Harness 1
10 620313651 Jumper CO2 Pressure Switch 1
11 32870 Splice 2
12 50705 Cable Tie 8
13 620920638 Label Low CO2 Light 1
14 620919569 Installation Instructions 1
CAUTION: Disconnect electrical power to the dispenser before proceeding with the
CO2 indicator light installation.
CAUTION: The Beverage System (water and CO2) must be depressurized and drained
before proceeding with the installation.
1.Remove the upper front panel which is secured to the cabinet by “hooks” that fit into slots
on the cabinet front flange. Lift up on the panel right and left sides to disengage the hooks
from the slots and then rotate the panel downward and forward to remove from the cabinet.
Disconnect the (3) electrical harnesses at the rear of the front panel.
2.Remove the lower front splash panel (2 screws).
3.Locate the CO2 supply line (1/4 beverage tubing) to the carbonator tank located on the
right side of the unit above the coldplate (see Fig. 1). Cut this line in an area that will be
accessible for future servicing and install the CO2 pressure switch with the fittings provided in
the kit (see Fig. 3).
4.Refer to Fig. 2 for installing the CO2 indicator light on the upper front panel. Remove the
lid and straw holder by loosening (3) screws at the “key-holes” and lifting up to clear the screw
heads. Remove the lower front ice portion control enclosure (4 screws) and disconnect the
electrical harnesses as needed for reworking the enclosure. Locate and drill a 1/2 in. diameter hole in the enclosure as shown in Fig. 2 for the indicator light. Insert the light from the
front and “snap” into the mounting hole.
5.Refer to the wiring detail of Fig. 4 to complete the electrical hook-up of the indicator light to
the pressure switch and the 24V beverage transformer power source.
6.Route the electrical wires to the CO2 pressure switch behind the beverage panel with the
harnesses from the unit’s electrical control box. Remove the (6) screws securing the bever-
Release Date: October 9, 2002 Revision: A
© 2002, IMI Cornelius Inc. - 1 - Publication Number: 620919569
Installation Instructions for DF/ED250PRO Field Kit
age panel to the cabinet. The panel can now be pulled down to provide access for routing the
pressure switch wires. Secure the wiring with the plastic cable ties provided in the kit to avoid
“pinching” (cutting) the wire insulation when the panels are assembled to the cabinet.
7.Connect electrical power to the unit. Before opening the water and CO2 supply valves to
the beverage system, verify that the CO2 indicator light is on. The indicator light should go off
when the CO2 supply valve is opened.
8.Check for proper operation of the ice portion control system and the beverage system.
Refer to the operation instructional label located on the upper front panel and the owners
manual. The unit is now ready for operation.
Beverage Valve
& Auto/Manual
BEVERAGE VALVE & AUTO/MANUAL
Harness From
HARNESS FROM E-BOX
E-Box
Manual Ice
Dispense PB
MANUAL ICE
DISPENSE PB
Switch Cord
SWITCH CORD
ASY FROM E-BOX
Asy From E-Box
Cut CO2 Supply
Line See CO2
CO2 Inlet Line
CO2 INLET
To Regulator
LINE TO REGULATOR
CO2 Supply Line
CO2 SUPPLY
CARBONATOR TANK
LINE TO
CUT CO2 SUPPLY
LINE. SEE CO2 PRESSURE SWITCH
Pressure Switch
INSTALL DETAIL
Install Detail
Figure 1.
Publication Number: 620919569 - 2 - © 2002, IMI Cornelius Inc.