Cooper-Atkins 5200 Installation Manual

Heartland Appliances Inc. 1050 Fountain St North, Cambridge, ON, N3H 4R7
Installation Requirements
Due to continuing product improvements, Heartland Appliances reserves the right to amend specifica-
tions without notice. Please contact Heartland for the most up to date information, as it applies to product
being purchased, or download latest Site Preparation Specifications from www.heartlandapp.com.
APPLIANCE REQUIREMENTS
Models 5200/5210 (page 1 of 2)
VENTING REQUIREMENTS
How-to Steps How-to Steps
Appliance Clearances (see Page 2 for additional details):
Sides of stove to adjacent surfaces: 1/2” (1.5 cm) min
Nickel trim to adjacent surfaces: 0” right , 1” (2.5 cm) left
Rear clearance: 0”
Closet right side to cabinetry: 0”
Top of counter to underside adjacent cabinetry: 18” (46 cm)
Cooktop to underside overhead cabinets: 30-1/4” (77 cm)
Edge of range to combustible wall on either side: 6” (15 cm)
Cut out width for range’s manin body: 48-3/4” (124 cm)
Max. countertop depth: 24” (61 cm); height: 36” (91 cm)
Max. overhead cabinet depth: 13” (33 cm)
Note: If unit is installed beside a refrigerator it is important that there be at least 5" (13 cm) between the refrigerator
Option 1 - Ventless installation:
• Requires no further set up (cooking fumes are drawn through pre-installed filters and exhausted through rear of hood, back into the room.
Option 2 - Venting directly outside:
Method 1 - Installation through outside wall.
Method 2 - Installation through attic to outside.
and range for proper air circulation.
Help Desk
877-650-5775
Gas
Gas hook-up must be performed by licensed gas fitter.
Natural Gas/Propane Conversion kits available from dealer or factory and must be performed by a licensed gas fitter
Pressure requirements: Nat Gas: 5” W.C. (min); LP gas: 11” W.C. (min)
5/8” minimum diameter flex line.
Connection: 1/2” NPT
An accessible manual shut off valve must be installed at the appliance.
Appliances installed in the state of Massachusetts
• This appliance can only be installed in the state of Massachusetts by a Massachusetts
Warning
licensed plumber or gas fitter
• This appliance must be installed with a three (3) foot / 36 inch long flexible gas connector
• A “T” handle type manual gas valve must be installed in the gas supply line to this appliance
Electrical
Electrical hookup must be performed by a licenced electrician
240 Volts 60Hz 3.8 Kw.
5 ft (1.5 m) power cord included with either 3 or 4 prong plug (please specify at time of order placement).
Stove must be electrically grounded in compliance with local codes. In the absence of local codes, with the National Electrical code ANSI/NFPA 70 “Latest Edition” in the US or in Canada with the Canadian Electrical Code, Part I, CSA Standard C22, or the Local National Electrical Code.
3 1/4" x 10" Exhaust adaptor included with range
Method 1
Method 2
Safety
Maximum ducting run: 25 linear feet - subtract 5' per 90 deg elbow and 2.5' per 45 deg elbow. Do not use more than two elbows. All duct work must be metal. Do not use plastic duct. range hood should never be exhausted into a wall cavity or an attic where an accumulation of grease could become a fire hazard.
Installation must be completed in accordance with all local &national codes.
To eliminate risk of burns or fire, installation of cabinet storage space above range should be avoided. Existing cabinets min clearance 30-1/ 4” (76 cm) .
Use only materials which conform to local codes in effect.
Gas cooking appliances produce heat and moisture - ensure kitchen is well ventilated. Prolonged intensive use may require additional ventilation (opening windows or addition of supplemetary air exhaust sources).
5
© 2005 HEARTLAND APPLIANCES INC.
Heartland Appliances Inc. 1050 Fountain St North, Cambridge, ON, N3H 4R7
j
Installation Requirements
Models 5200/5210 (page 2 of 2)
Due to continuing product improvements, Heartland Appliances reserves the right to amend specifica-
tions without notice. Please contact Heartland for the most up to date information, as it applies to product
being purchased, or download latest Site Preparation Specifications from www.heartlandapp.com.
Dimensions
Range Hood Outlet
3-7/8”
(10 cm)
62-3/8” (159 cm)
28”
(72 cm)
37-3/4” (96 cm)
11-3/8” (29 cm)
39-3/4”
(101 cm)
(142 cm)
36-1/8”
56”
36-1/8”
(92 cm)
30”
(76 cm)
3-1/4” x 10”
(8.3 x 25.4 cm)
4-3/4”
(12 cm)
Gas Inlet 1/2” NPT
Exhaust Hood Receptacle
47-1/2”
(121 cm)
20”
(51 cm)
Oven Exhaust
Power Cord
39-3/4”
(101 cm)
66-1/4”
(169 cm)
14”
(36 cm)
52”
with bottom drawer fully open
(132 cm)
Help Desk
877-650-5775
29-1/2” (75 cm)
43-3/4”
(111 cm)
with oven
door open
0” clearan ce
to the back
3” (7.6 cm)
Rough In
Measurements
66 3/4”
(169.5 cm)
with std cresting
62 7/8”
(160 cm)
without cresting
Range Hood Outlet 3-1/2” x 10- 1/2”
8.9 x 26.7 cm)
56” (142 cm)
(
20”
(51 cm)
(33 cm)
13”
cabinet depth
counter
depth
5-3/8”
(14 cm)
Gas
(6” clearance to any combustible wall)
6” (16 cm)
24”
(61 cm)
Outlet
12”
(30.5 cm)
30”
(76 cm)
Receptacle Location (use flush mounting
uction box)
21” (54 cm)
30-1/4”
(77 cm)
(2.5 cm)
min 36”
(91.4 cm)
Note: 40” closet cutout includes
1”(2.5 cm) stove clearance on left side
0”
0”
min 18” (46 cm)
40” (102 cm)
1”
48-3/4”
(124 cm)
6
© 2005 HEARTLAND APPLIANCES INC.
12-07-2006