ISO 17025 Calibrated Equipment - 900MHz
WIRELESS MONITORING
OVERVIEW
Cooper-Atkins provides temperature transmitters to monitor vaccine storage temperatures that are specifically calibrated to conform to CDC requirements for use in the Vaccines For Children (VCF) program. Each of our devices is covered by a Certificate of Traceability and Calibration.
This confirms that the measurement standards and instruments used during product calibration are traceable to an ISO/IEC 17025 accredited testing laboratory and that the calibration process is compliant with ISO/IEC 17025 requirements.
FEATURES |
BENEFITS |
||
• |
3 different simulator probes available |
• |
Accurately simulates product temperature in ambient conditions |
• |
On-site testing/certification |
• |
Saves time and labor in the recertification process |
• |
Calibrated to specific temperature ranges |
• |
Refrigerator or freezer environment monitoring available |
• Accurate to ±1°F and meets the CDC’s VFC Program recommendations |
• Compliant with ISO 17025 standards |
||
|
|
|
|
SPECIFICATIONS
Products with a “-R” suffix are calibrated specifically for refrigeration use. Products with a “-F” suffix are calibrated specifically for freezer use.
#16901-025-R |
#16903-025-R |
#16905-025-R |
Temperature Transmitter (10080-DT) and |
Temperature Transmitter (10080-DT) and |
Temperature Transmitter (10080-DT) and |
Refrigerator Glycol Simulator (10112) |
Refrigerator Solid Simulator (10113) |
Refrigerator Vial Solid Simulator (10114) |
• Temperature Range: -25° to 180°F |
• Temperature Range: -25° to 180°F |
• Temperature Range: -25° to 180°F |
(-32° to 82°C) |
(-32° to 82°C) |
(-32° to 82°C) |
• Calibration Test Point: 41°F |
• Calibration Test Point: 41°F |
• Calibration Test Point: 41°F |
• Tolerance: ±1°F |
• Tolerance: ±1°F |
• Tolerance: ±1°F |
#16901-025-F |
#16903-025-F |
#16905-025-F |
|||
Temperature Transmitter (10080-DT) and |
Temperature Transmitter (10080-DT) and |
Temperature Transmitter (10080-DT) and |
|||
Freezer Glycol Simulator (10112) |
Freezer Solid Simulator (10113) |
Freezer Vial Solid Simulator (10114) |
|||
• Temperature Range: -25° to 180°F |
• Temperature Range: -25° to 180°F |
• Temperature Range: -25° to 180°F |
|||
|
(-32° to 82°C) |
|
(-32° to 82°C) |
|
(-32° to 82°C) |
• |
Calibration Test Point: -13°F |
• |
Calibration Test Point: -13°F |
• |
Calibration Test Point: -13°F |
• |
Tolerance: ±1°F |
• |
Tolerance: ±1°F |
• |
Tolerance: ±1°F |
#16901-025-R / #16901-025-F |
#16903-025-R / #16903-025-F |
#16905-025-R / #16905-025-F |
900 MHz Transmitter with Glycol Simulator Probe |
900 MHz Transmitter with Solid Simulator Probe |
900 MHz Transmitter with Vial Solid Simulator Probe |
Cooper-Atkins Corporation | Accuracy to the Highest Degree