Control Techniques Commander SL Sales Brochure

Commander SL
SIMPLE MOTOR SPEED CONTROL UP TO 5HP
For applications where cost is critical, Control Techniques have
designed the Commander SL – Simple and Lite!
230 and 460VAC, 1ph and 3ph
1/3 to 5HP
Typical
Applications
Mixer
Simple and Easy
Extruder
Reliability
Fan
Energy Saving
Pump
Accurate Control
Conveyor
Smooth Acceleration
Motor status readout…
Stop/Reset…
Easy set up instructions…
Clearly marked, practically sized connectors
Panel mounting...
(DIN-rail up to 2 Hp)
Start…
L1 L2 L3/N U V W
PE PE
AC Supply
1 3456
78910
2
0V
Remote speed
reference input
+10V output
Analog/Digital
Output
24V
Digital Input 1
Digital Input 2
Digital Input 3
RL1
RL2
Status Relay
Connected and running within minutes
Speed
E a s y D
r i v
e E a s y D
r
i
v
e
E
E
a
a
s y
s
D
y
r
D ve
i
v
r
e
i
E a s y D
r i v e
E a s y D
r i v e
E a s y D
r i v e
Environment
IP20
NEMA 1 rating with optional cover
Ambient temperature -10 to +40°C @ 3 kHz switching
Maximum operating temperature 50°C with derate
Humidity 95% maximum (non-condensing)
Electromagnetic Immunity complies with EN61800-3
and EN61000-6-3 and 4
Electromagnetic Emissions
complies with EN61000-6-3
(residential) and EN61000-6-4
(industrial) generic standards
with optional footprint EMC
filter
Ratings
Order code
SLA1200025
SLA1200037
SLA1200055
SLA1200075
SLBD200110
SLBD200150
SLCD200220
Size
A
A
A
A
B
B
C
Motor Power 100% continuous
output current (A)
1.7
2.2
3.0
4.0
5.2
7.0
9.6
kW
0.25
0.37
0.55
0.75
1.1
1.5
2.2
hp
0.33
0.5
0.75
1.0
1.5
2.0
3.0
150% overload
current for 60s (A)
2.6
3.3
4.5
6.0
7.8
10.5
14.4
h
Order Code
SLB3400037
SLB3400055
SLB3400075
SLB3400110
SLB3400150
SLC3400220
SLC3400400
Size
B
B
B
B
B
C
C
Motor Power 100% continuous
output current (A)
1.3
1.7
2.1
2.8
3.8
5.1
9.0
kW
0.37
0.55
0.75
1.1
1.5
2.2
4.0
hp
0.5
0.75
1.0
1.5
2.0
3.0
5.0
150% overload
current for 60s (A)
2.0
2.6
3.2
4.2
5.7
7.7
13.5
Control
Open loop vector control
Dynamic motor flux V/Hz for energy saving
Quadratic motor flux V/Hz for fan and pump optimization
Speed reference input: 0-10V or 4-20mA
3 digital inputs (not stop, run, jog)
Switching frequency: 3 (default) – 6 – 12 kHz
Output frequency 0 to 1,500 Hz
Acceleraton and Deceleration ramps
Positive logic control
Protection
Undervoltage, Supply and DC Link overvoltage, Phase loss,
Drive overload, Instantaneous overcurrent, Short circuit,
Ground fault, Drive thermal, Watchdog, Motor thermal
General Characteristics
Maximum overload 150% of rated current for 60s
Intelligent Thermal Management (ITM) optimizes switching frequency
4 preset speeds
Flying start
Mains dip ride through
Automatic no-spin autotune for fast performance optimization
Programming Option
Easy commissioning pack, order code 9500-0078 (requires
additional CT-COMS for MMS-cable)
Drive
size
A
B
C
w
mm
75
85
100
in
2.95
3.35
3.93
h
mm
140
190
240
in
5.5
7.48
9.45
d
mm
145
156
173
in
5.71
6.14
6.81
Dimensions
Supply voltage and frequency
1 phase 200 to
240VAC ± 10%
48 to 62Hz
1 or 3 phase 200
to 240VAC ± 10%
48 to 62Hz
Supply voltage and frequency
3 phase 380 to
480VAC ± 10%
48 to 62Hz
Control Techniques-Americas LLC, 12005 Technology Drive, Eden Prairie, MN 55344
Tel: (800) 397-3786 Fax: (952) 995-8099 Website: www.emersonct.com
d
w
P/N SLBRO-1106 REV: 11/06
Loading...