Control Techniques Commander C200 AC Drives Catalog Page

Commander C200 AC Drives
S
I
L
3
Sa e y In egr t y Level
Enhance throughput with machine safety, communications, and built-in PLC
The Commander C200 delivers benchmark functionality at no added cost to the base drive itself. Plug-in options, dynamic performance, PLC functionality and other advanced features such as fieldbus, Ethernet, and Modbus RTU communications ensure that in more complex applications Commander C200 can deliver more than the average general purpose drive - giving you lower cost solutions and better productivity in your motor control applications.
Enhance up-time and system flexibility
Flexible system integration and remote diagnostics through optional industrial
Flexible I/O expandable with SI-I/O option module
Enhanced functionality and onboard PLC programming provides a low-cost system
solution, minimizing the need for additional equipment such as PLCs
High performance open-loop motor control
RFC-A (Rotor Flux Control) algorithm for exceptional induction motor control of
demanding applications
Closed loop current control without a position feedback device
Speed control for conveyors, fans, pumps, and mixers, where their function is
controlled remotely with fieldbus or Ethernet communications
Key data
Heavy Duty Ratings: 0.33 hp to 150 hp (0.25 kW to 110 kW) Normal Duty Ratings: 0.33 hp to 200 hp (0.25 kW to 132 kW)
Commander C200 Frame Size 3
Voltage ratings
100 / 120 VAC ± 10%
200 / 240 VAC ± 10%
380 / 480 VAC ± 10%
Control mode
Open loop vector or V/Hz induction motor control
Open loop Rotor Flux Control for induction motors (RFC-A)
ü
ü
ü
ü
ü
Supply phases: Frame size 1 and 2: 110 V drives 1Ø,
230 V drives 1Ø or 3Ø; Frame size 7 and larger 3Ø; 460 V drives 3Ø
Control connections: 2x Analog inputs, 4x Digital inputs, 1x Analog output,
1x Digital I/O, 1x Relay Drive rating: IP21 / UL open class as standard Keypad: Fixed LED Option slots: 1 (frame size 2 and above) Parameter cloning via: PC tools, SD card
How to select a drive (Consult online catalog for complete drive information)
1. Electrical Considerations
What is the supply voltage?
Single or 3Ø input power?
What is the motor rating?
Continuous current – FLA (Full Load Amps)
Select the drive based on motor Amps rather than horsepower
2. Load Type (choose one)
Normal Duty: Peak current is 110% of drive rating (fans, pumps, etc.)
Heavy Duty: Peak current is 180% (mixers, conveyors, etc.)
3. Drive Mechanical Mounting
Panel mounting – as standard
Wall mounting – UL conduit kits are available
Through panel mounting – frames 5 and up
0
9
0
1
O
S
I
L
A
A
V
P
O
P
R
COMMANDER C200 AC Drives for Industrial Applications
Order Information & Ratings
SOFTW
115 VAC, Single Phase 50/60 Hz Input, 230 VAC 3-Phase Output
Commander C200
Order Code*
C200-01100017A 1 0.33 1.7 0.33 1.7 C200-01100024A 1 0.5 2.4 0.5 2.4 C200-02100042A 1 1 4.2 1 4.2 C200-02100056A 1 1.5 5.6 1.5 5.6
Input
Phase
230 VAC, Single & 3-Phase Input, 3-Phase Output, 50/60 Hz Input
C200-01200017A 1 0.33 1.7 0.33 1.7 C200-01200024A 1 0.5 2.4 0.5 2.4 C200-01200033A 1 0.75 3.3 0.75 3.3 C200-01200042A 1 1 4.2 1 4.2 C200-02200024A 1, 3 0.5 2.4 0.5 2.4 C200-02200033A 1, 3 0.75 3.3 0.75 3.3 C200-02200042A 1, 3 1 4.2 1 4.2 C200-02200056A 1, 3 1.5 5.6 1.5 5.6 C200-02200075A 1, 3 2 7.5 2 7.5 C200-03200100A 1, 3 3 10 3 10 C200-04200133A 1, 3 3 13.3 3 13.3 C200-04200176A 3 5 17.6 5 17.6 C200-05200250A 3 10 30 7.5 25 C200-06200330A 3 15 50 10 33 C200-06200440A 3 20 58 15 44 C200-07200610A 3 25 75 20 61 C200-07200750A C200-07200830A 3 40 117 30 83 C200-08201160A 3 50 149 40 116
C200-08201320A 3 60 180 50 132 C200-09201760x** 3 75 216 60 176 C200-09202190x** 3 100 266 75 219
3 30 94 25 75
460 VAC, Three Phase Input, 3-Phase Output, 50/60 Hz Input
C200-02400013A 3 0.5 1.3 0.5 1.3
C200-02400018A 3 0.75 1.8 0.75 1.8
C200-02400023A 3 1 2.3 1 2.3
C200-02400032A 3 1.5 3.2 1.5 3.2
C200-02400041A 3 2 4.1 2 4.1
C200-03400056A 3 3 5.6 3 5.6
C200-03400073A 3 3 7.3 3 7.3
C200-03400094A 3 5 9.4 5 9.4
C200-04400135A 3 7.5 13.5 7.5 13.5
C200-04400170A 3 10 17 10 17
C200-05400270A 3 20 30 20 27
C200-05400300A 3 20 30 20 30
C200-06400350A 3 25 38 25 35
C200-06400420A 3 30 48 30 42
C200-06400470A 3 50 63 30 47
C200-07400660A 3 60 79 50 66
C200-07400770A 3
C200-07401000A 3 75 112 75 100
C200-08401340A 3 125 155 100 134
C200-08401570A 3 150 184 125 157 C200-09402000x** 3 150 221 150 180 C200-09402240x** 3 200 255 150 211
*
Add 10101AB100 to the base order code when ordering standard US (60Hz) default products
**x= A or E (9E frame requires an external AC Line Reactor)
Normal Duty Heavy Duty
HP Amps HP Amps
75 94 60 77
Dimensions & Weights
Frame Size
01 6.3 x 3.0 x5.1 1.7 02 8.1 x 3.1 x 5.9 2.2 03 8.9 x 3.5 x 6.3 3.3 04 10.9 x 4.5 x 6.9 6.9 05 15.4 x 5.6 x 7.9 16.3 06 15.4 x 8.3 x 9.0 30.9 07 21.9 x 10.6 x 11.0 61.7
08 31.7 x 12.2 x 11.4 114.6 09E 39.8 x 12.2 x 11.4 101.4 09A 43.6 x 12.2 x 11.4 146.6
Additional distance should be added to the height dimension (H) when the AI options are fitted.
Dimensions
H x W x D (in)
OPTIONS AT-A-GLANCE
Option Description Order Code
Drive Configuration
& Programming
Operator Interfaces
Input / Output*** Extended I/O SI-I/O
Communications***
Application Programming
Software & Diagnostics
Power Accessories
Environmental Protection
& Cable Management
***frame sizes 2 and up accept 1 SI option ****Shielded RS485 patch cable, CAT5e, conductive metal RJ45 connectors, XXX=cable length in
5 foot increments (max 330 ft), standard lengths are (005, 010, 015, 025 and 050)
Diagnostic Software
Our Drive Diagnostics APP allows users to quickly diagnose faults. In
the unlikely event that you get a drive error, download our complimentary
Order String - Frame Size Key
Example: C200-XX_ _ _ _ _ _ _ XX = Frame Size (01-09 above)
Diagnostics Tool app. Just input the error code on your device and you’ll be given a solution.
W
Weight
(lbs)
D
Configuration software CONNECT
Drive to PC USB cable
(requires a 485 adaptor) Parameter cloning 4 GB
(includes 4 GB SD card)
Parameter cloning
(requires an SD card)
8 GB SD card CTSD8GB Remote LCD display REMOTE-KEYPAD Remote LCD display with real-time clock
Remote display cable UM-LCD-485-XXX****
Modbus RTU AI-485-ADAPTOR
Modbus RTU with 24 V AI-485-24V-ADAPTOR
PROFIBUS DP SI-PROFIBUS
DeviceNet SI-DEVICENET CANopen SI-CANOPEN
PROFINET RT SI-PROFINET-V2
EtherCAT SI-ETHERCAT
EtherNet/IP, Modbus TCP SI-ETHERNET
PLC programming MACHINE-CONTROL-STUDIO Digital oscilloscope CTSCOPE External EMC filter
Line & load reactors
Dynamic braking resistors
UL Type 1 conduit kits
Retrofit for
Commander SK
Fan replacement kits
CT-USB-CABLE
AI-SMART-ADAPTOR
AI-BACKUP-ADAPTOR
REMOTE-KEYPAD-RTC
See the General Purpose
AC Drives brochure
See the General Purpose
AC Drives brochure
H
P/N SEL-C200 09/19
ARE
INCLUDED
5-year warranty
Terms & Conditions apply
Loading...