Control Techniques Active Input Single Drives Data Sheet

Active Input Single Drives - regeneration and harmonic elimination
200V
192 55 75 156
45
60
248 75 100 192
55
75
312 90 125 250
75
100
1 x SPMU1402
[5]
200-2
1 x SPMU1402
[5]
1 x SPMU1402
[5]
350
[1]
110
[1]
150
[1]
290
90
125
1 x SPMU1402
[5]
200-1 200-3 200-2 200-4 200-3 200-5 200-4
Normal Duty Heavy Duty
Fig.
SPMD1221-R SPMD1222-R SPMD1223-R SPMD1224-R
Top Level
Drive
Order Code
Drive
Drive Order Code Items
Active Input Kits
[7]
Modules
Rectifier
Order Kit based on
required voltage and duty
Max
Cont.
Current
Typical Motor
Output
Max
Cont.
Current
Typical Motor
Output
Master
(A)
@220V
(kW)
@230V
(HP)
(A)
@220V
(kW)
@230V
(HP)
@ 575V
(HP)
@ 690V
(kW)
@ 575V
(HP)
@ 690V
(kW)
@ 575V
(HP)
Normal
Duty
Normal
Duty
Heavy
Duty
Heavy
Duty
575V / 690V
125 125110 125 100
90
100
16 2 x SPMA1621 2
690-217 1 x SPMA1621 + 1 x SPMD1621 2
18 2 x SPMD1621 2 1 x SPMC1601
144 150132 150 125
110
125
16 2 x SPMA1622 2
690-317 1 x SPMA1622 + 1 x SPMD1622 2
18 2 x SPMD1622 2 1 x SPMC1601
168 150160 150 144
132
150 18 2 x SPMD1623 2 1 x SPMC1601 690-4
192 200185 200 168
160
150 18
SPMA1621-R
SPMA/ D1621-R
SPMD1621-R SPMA1622-R
SPMA/ D1622-R
SPMD1622-R SPMD1623-R SPMD1624-R 2 x SPMD1624 2 1 x SPMC1601 690-6
690-1
690-2
690-3
690-4
575-2
575-3
575-4 575-6
575-1
575-2
575-3 575-4
400V
205 110 150 180
90
150
16 2 x SPMA1421 2
400-217 1 x SPMA1421 + 1 x SPMD1421 2
18 2 x SPMD1421 2 1 x SPMC1402
236 132 200 210
110
150
16 2 x SPMA1422 2
400-317 1 x SPMA1422 + 1 x SPMD1422 2
246 132 200 210
110
150 18 2 x SPMD1422 2 1 x SPMC1402
290 160 250 246
132
200 18 2 x SPMD1423 2 1 x SPMC1402 400-3
350
[1]
200
[1]
300
[1]
290
160
250 18
SPMA1421-R
SPMA/ D1421-R
SPMD1421-R SPMA1422-R
SPMA/ D1422-R
SPMD1422-R SPMD1423-R SPMD1424-R 2 x SPMD1424 2 1 x SPMC1402 400-4
400-1
400-2
400-3
400-3
@400V
(kW)
@460V
(HP)
@400V
(kW)
@460V
(HP)
Fig 16 - SPMA Fig 17 - SPMA + SPMD Fig 18 - SPMD + SPMC
[2]
A separate soft start must be provided for the DC link. Please contact your supplier
See notes on page 16
Active Input Multiple Drives - regeneration and harmonic elimination
400V
390 225 300 342
185
300
468 280 400 400
225
350
552 315 450 468
280
400
19 4 x SPMD1421 2 2 1 x OTL411 400-6 19 4 x SPMD1422 2 2 1 x OTL412 19 4 x SPMD1423 2 2 1 x OTL413
666
[1]
350
[1]
550
[1]
552
315
450
702 400 600 600
315
500
19 4 x SPMD1424 2 2 1 x OTL414 400-9 19 6 x SPMD1422 2 4 3 x OTL402
828 450 700 702
400
650
19 6 x SPMD1423 2 4 3 x OTL403
1000
[1]
550
[1]
850
[1]
828
450
750 19 6 x SPMD1424 2 4 3 x OTL404 400-11
1104 630 900 937
550
800 19 8 x SPMD1423 2 6 4 x OTL403
1 x SPMC1402 1 x SPMC1402 1 x SPMC1402 1 x SPMC1402 1 x SPMC1402 1 x SPMC1402 1 x SPMC1402 1 x SPMC1402 400-12
400-5 400-7 400-6 400-7 400-7
400-7
400-10 400-8 400-10 400-10
400-10 400-12
1333
[1]
750
[1]
1100
[1]
1104
630
950 19 8 x SPMD1424 2 6 4 x OTL4041 x SPMC1402 400-14 400-12
For higher currents, please contact your supplier. The maximum number of parallel output stages is 10, as on next line:
3333
[1]
1900
[1]
2900
[1]
2761
1500
2400 19
SPMD1421-2R SPMD1422-2R SPMD1423-2R SPMD1424-2R SPMD1422-3R SPMD1423-3R SPMD1424-3R SPMD1423-4R SPMD1424-4R
SPMD1424-10R 20 x SPMD1424 2 18 10x OTL4041 x SPMC2402 400-26 400-24
575V / 690V
238 200 250 190
185
200
274 250 300 238
200
250
320 300 350 274
250
300
19 4 x SPMD1621 2 2 1 x OTL611
690-7
19 4 x SPMD1622 2 2 1 x OTL612 19 4 x SPMD1623 2 2 1 x OTL613
365 350 400 320
300
350
411 400 450 357
350
350
19 4 x SPMD1624 2 2 1 x OTL614
690-11
19 6 x SPMD1622 2 4 3 x OTL602
480 450 500 411
400
450
19 6 x SPMD1623 2 4 3 x OTL603
548 500 600 480
450
500 19 6 x SPMD1624 2 4 3 x OTL604 690-14
640 630 700 548
500
600 19 8 x SPMD1623 2 6 4 x OTL603
1 x SPMC1601 1 x SPMC1601 1 x SPMC1601 1 x SPMC1601 1 x SPMC1601 1 x SPMC1601 1 x SPMC1601 1 x SPMC1601 690-16
690-5 690-8 690-7 690-9 690-8
690-9
690-12 690-10 690-13 690-12
690-13 690-15
731 700 800 640
630
700 19 8 x SPMD1624 2 6 4 x OTL6041 x SPMC1601 690-18 690-16
For higher currents, please contact your supplier. The maximum number of parallel output stages is 10, as on next line:
1828 1800 2000 1600
1550
1750 19
SPMD1621-2R SPMD1622-2R SPMD1623-2R SPMD1624-2R SPMD1622-3R SPMD1623-3R SPMD1624-3R SPMD1623-4R SPMD1624-4R
SPMD1624-10R 20 x SPMD1624 2 18 10x OTL6041 x SPMC2601 690-30 690-28
575-7
575-11
575-14 575-16
575-5 575-8 575-7 575-9 575-8
575-9
575-12 575-10 575-13 575-12
575-13 575-15
575-18 575-16
575-30 575-28
@400V
(kW)
@460V
(HP)
@400V
(kW)
@460V
(HP)
@690V
(kW)
@575V
(HP)
@690V
(kW)
@575V
(HP)
200V
364 110 150 296
90
125
471 132 200 364
110
150
592 160 250 475
150
200
19 4 x SPMD1221 2 2 1 x OTL411 200-7 19 4 x SPMD1222 2 2 1 x OTL412 19 4 x SPMD1223 2 2 1 x OTL413
665 200 250 551
160
200
For higher currents, please contact your supplier. The maximum number of parallel output stages is 10.
19 4 x SPMD1224 2 2 1 x OTL414 200-11
1 x SPMU1402
[5]
1 x SPMU1402
[5]
1 x SPMU1402
[5]
1 x SPMU1402
[5]
200-6 200-8 200-7 200-9 200-8
200-9
Normal Duty Heavy Duty
Fig.
SPMD1221-2R SPMD1222-2R SPMD1223-2R SPMD1224-2R
Top Level
Drive
Order Code
Drive
Drive
Active Input Kits
[7]
Modules Inductors
Output
Order Kit based on
required voltage and duty
Rectifier
Max
Cont.
Current
Typical Motor
Output
Max
Cont.
Current
Typical Motor
Output
Master
Slave
(A)
@220V
(kW)
@230V
(HP)
(A)
@220V
(kW)
@230V
(HP)
Normal
Duty
Normal
Duty
Heavy
Duty
Heavy
Duty
Fig 19 - SPMD x 4 to x 20 + SPMC
See notes on page 16
Loading...