Condtrol Smart 20 Manual

0 (0)
Condtrol Smart 20 Manual

LASER DISTANCE METER CONDTROL SMART 20

User manual

Display

5

6

1.Main display line

2.Secondary display line

3.Battery charge level

4.Measuring unit

5.Laser beam indication

6.Reference point

LASER DISTANCE METER CONDTROL SMART 20

User manual

MESSAGE CODES

While operation, the following codes/symbols may appear on the display:

Message

Cause

Solution

204

Calculation error

Refer to user manual, repeat

the procedure.

 

 

208

Excessive current

Please contact the distributor

or authorized service center.

 

 

220

Batteries are low

Replace the batteries.

 

Operating

Cool down the device to

252

temperature is

temperature within 0…+400С.

 

too high

 

 

Operating

Warm up the device to

253

temperature is

temperature within 0…+400С

 

too low

 

255

Received signal is

Make measurements against

 

too weak

surface with better reflective

 

 

properties. Use a reflecting

 

 

plate.

 

 

 

LASER DISTANCE METER CONDTROL SMART 20

User manual

Congratulations on your purchase of laser distance meter CONDTROL SMART 20.

Safety instructions can be found in the end of this user manual and should be carefully read before you use the device for the first time.

FUNCTIONS/APPLICATIONS

Laser distance meter SMART 20 is intended to measure distance at indoor building areas.

PACKAGE

1. Laser distance meter – 1pc.

2. Batteries (type ААА) - 2 pcs.

3. User manual – 1 pc.

SPECIFICATIONS

Working range

0,2…20m*

 

 

Smallest unit displayed

1mm

 

 

Measuring accuracy

±3mm**

 

 

 

Class II,

Laser type

630-670nm,

 

< 1mW

Continuous measurement (tracking)

+

 

 

Display backlight

+

LASER DISTANCE METER CONDTROL SMART 20

User manual

OPERATION Insert/replace batteries

Remove the battery cover. Insert the batteries, observing correct polarity. Put the battery cover back. Remove the batteries when the device is not used for a long time to avoid corrosion and battery depletion. Both batteries should be replaced at the same time. Both batteries must be of the same brand with the same charge level. Replace batteries when you see symbol on the display.

Switch on/off

 

Switch on: press and hold for 1 sec. button

.

The device will turn on and enter single distance measuring mode. Laser beam will turn on simultaneously. Laser beam automatically turns off in 30 seconds after the last operation.

Switch off: press and hold for 1 sec. button

.

 

In order to save battery power the device will

switch off

automatically within 3 minutes after the last operation.

LASER DISTANCE METER

 

CONDTROL SMART 20

 

 

 

 

 

 

 

 

 

 

 

 

 

User manual

 

 

 

 

 

 

 

 

 

 

Make

measurements against

256

 

Received signal is

surface with lower reflective

 

properties.

Use a reflecting

 

 

too strong

plate.

 

 

 

 

Outside of

Carry

out

measurements

261

 

within

the

range acceptable

 

 

measuring range

for this device.

500

 

Hardware error

Switch on/off the device several

 

times. If this error still appears,

 

 

 

 

please contact the distributor

 

 

 

 

or authorized service center.

LASER DISTANCE METER CONDTROL SMART 20

User manual

CARE AND MAINTENANCE

Attention! The instrument is a high precision device and requires careful handling. The following recommendations will extend the life of the device:

-Do not point the device at the sun

-Protect the device from bumps, falls and excessive vibration; do not let liquids, construction dust and foreign objects get inside the device.

-Do not expose the device to extreme temperatures.

-If liquids get inside the device first remove batteries, then contact a service center.

-Do not store or use the device under high humidity conditions for a long time.

-Clean the device with soft wet cloth.

-Keep device optics clean and protect it from mechanical damage.

-Сarry out control measurements occasionally, especially if the device is subject to excessive mechanical or other impact, before and after making important measurements.

LASER DISTANCE METER CONDTROL SMART 20

User manual

UTILIZATION

Expired tools, accessories and package should be passed for waste recycle. Please send the product to the following address for proper recycle:

CONDTROL GmbH

Wasserburger Strasse 9

84427 Sankt Wolfgang

Germany

Do not throw the product in municipal waste!

AccordingtoEuropeandirective2002/96/ЕCexpiredmeasuring tools and their components must be collected separately and submitted to environmentally friendly recycle of wastes.

LASER DISTANCE METER

 

CONDTROL SMART 20

 

 

 

 

 

 

 

 

 

User manual

 

 

 

Automatic shutdown of laser

 

30sec.

 

 

Automatic shutdown of laser distance meter

180sec.

 

 

 

Storage temperature

 

-10…+60°С

 

 

 

Working temperature

 

0…+40°С

 

 

 

 

 

Battery

 

2 х 1.5V AAA LR3

 

(alkaline)

 

 

 

 

 

 

 

 

 

Battery life

 

up to 5000

 

measurements

 

 

 

 

 

 

 

Dimensions

 

100х40х25mm

 

 

 

Weight

 

80g

 

 

 

 

 

*Use a reflecting plate to increase the measurement range during daylight or if the target has poor reflective properties.

**In favorable conditions (good target surface properties, room temperature) up to 10 m. In unfavorable conditions, such as intense sunshine, poorly reflecting target surface or considerable temperature variations, accuracy can decrease at distance over 10m.

LASER DISTANCE METER CONDTROL SMART 20

User manual

Display backlight

When the device is on, backlight turns on automatically when you press button . The backlight will turn off automatically in 10 seconds after last operation.

Reference point

Reference point is the bottom end of the device.

Measuring unit.

Press simultaneously buttons and to select the reference point – m (meter) or ft (foot).

MEASUREMENTS

1) Single distance measurement

Short press button to switch on the device. Laser beam will be on. Point the laser beam at the target and short press button for single distance measurement. The result of measurement will appear in the main line on the display.

To perform next single distance measurement press button to turn on the laser beam and then press again.

LASER DISTANCE METER CONDTROL SMART 20

User manual

PRODUCT DESCRIPTION

Display

Switch on / turn on laser beam

/ make measurement /continuous measurement

Switch off/clear

LASER DISTANCE METER CONDTROL SMART 20

User manual

2) Continuous measurement (tracking)

When in single distance measurement mode press and hold for 1 sec. button . The device will take measurements one after the other, showing the last measured value. To stop continuous measurement press button or .

To exit the mode short press .

LASER DISTANCE METER CONDTROL SMART 20

User manual

SAFETY REGULATIONS

The user manual should be read carefully before you use the device for the first time. Unintended use of the device can be dangerous for human’s health and cause serious injury. Keep this user manual. If the device is given to somebody for temporary use, be sure to enclose user manual to it.

-Do not misuse the device.

-Donotremovewarningsignsandprotectthemfromabrasion, because they contain information about safe operation of the device.

Laser radiation!

Do not stare into beam Class 2 laser

<1 mW, 630-670 nm IEC 60825-1: 2007-03

-Do not look into the laser beam or its reflection, with unprotected eye or through an optical instrument. Do not point the laser beam at people or animals without the need. You can dazzle them.

-To protect your eyes close them or look aside.

-It is prohibited to disassemble or repair the device yourself.

Entrust device repair to qualified personnel and use original spare parts only.

-Do not use the device in explosive environment, close to flammable materials.

LASER DISTANCE METER CONDTROL SMART 20

User manual

- Avoid heating the batteries to avoid the risk of explosion and electrolyte leakage. In case of liquid contact with skin, wash it immediately with soap and water. In case of contact with eyes, flush with clean water during 10 minutes and consult the doctor.

LASER DISTANCE METER CONDTROL SMART 20

User manual

WARRANTY

All CONDTROL GmbH products go through post-production control and are governed by the following terms of warranty. The buyer’s right to claim about defects and general provisions of the current legislation do not expire.

1)CONDTROL GmbH agrees to eliminate all defects of the device, discovered during the warranty period, that represent defect in material or workmanship in full volume and at its own expense.

2)The warranty period is 24 months and starts from the date of purchase by end consumer (see the original supporting document).

3)The warranty doesn’t cover defects resulting from wear and tear or improper use, malfunction of the device caused by failure to observe the instructions of this user manual, untimely maintenance and service and insufficient care, the use of nonoriginal accessories and spare parts. Modifications in design of the device relieve the seller from responsibility for warranty works. The warranty doesn’t cover cosmetic damage, that doesn’t hinder normal operation of the device.

4)CONDTROL GmbH reserves the right to decide on replacement or repair of the device.

5)Other claims not mentioned above, are not covered by the warranty.

6)After warranty works are carried out by CONDTROL GmbH warranty period is not renewed or extended.

7)CONDTROL GmbH is not liable for loss of profit or

LASER DISTANCE METER CONDTROL SMART 20

User manual

inconvenience associated with a defect of the device, the rental cost of alternative equipment for the period of repair.

This warranty applies to German law except provision of the United Nations Convention on contracts for the international sale of goods (CISG).

In warranty case please return the device to retail seller or send it with defect description to the following address:

CONDTROL GmbH

Wasserburger Strasse 9

84427 Sankt Wolfgang

Germany

Loading...
+ 1 hidden pages