When used with the FDW1000 series of fiber optic Wiegand extender modules, the ComNet™ EXP100 Expansion Module enables additional Wiegand control panels, readers, and associated door/gate hardware to be added to the network. The 2-wire RS-485 data interface between the expansion modules provides a secure and completely supervised connection, with excellent immunity to electrical noise and interference. Up to 8 EXP100s can be used in a drop-and-repeat/daisy-chain topology, and each EXP100 may be set to a unique address (1 thru 15) via DIP-switch selection.
An auxiliary I/O (input/output) interface is available for ascertaining door, gate, and control panel status and signaling, and a relay interface provides the door strike or gate activation functions. See Figures 10 and 11 beginning on Page 5 for a guide to the I/Os and Relay Controls.
The EXP100 is supplied as a remote unit for door or gate locations or a central unit for control panel installation. See Figures 3 through 5 on Page 3 for Central and Remote Dip Switch Settings.
These extenders are designed for long-term, reliable operation in harsh industrial environments, and a fault-specific LED indicator is provided for rapidly ascertaining the operating status of the extender and the link. See Figure 17 on Page 12 for an explanation of LED indicators.
Packaged in a rugged aluminum housing, the EXP100 is designed for shelf or surface mounting. See Figure A on Page 12 for mounting instructions.
See Figures 1 – 17 for complete installation details.
Rev. 04.18.13
INS_EXP100_REV– 12/04/12 PAGE 1
INSTALLATION AND OPERATION MANUAL EXP100
FIGURE 1 – EXP100/C CENTRAL DATA EXTENDER
BLACK
BLACK& WHITE/RED
Power Supply: Input: 8–16 VDC @ 200mA Max Output: +5 VDC @ 100mA
18–16VDC
2GND
STATUS LED
EXP100/C CENTRAL
EXPANSION
MODULE
1RS-485(+)
2RS-485(–)
3
4 5 6LED IN
7D1/DOUT
8D0/COUT
Power Connections Relay Connections
1 - 8 – 16VDC Power IN (+) 1 N.O. Contact
2 - GND Power IN (–) 2 Common
Data Connections 4 N.O. Contact
1 RS-485(+) RS-485 Input 5 Common
2 RS-485(–) RS-485 Input 6 N.C. Contact
3 +5 VDC OUT - 5V Power Out 7 RS232 Serial Data OUT
4 Analog Input #2 8 RS232 Serial Data IN
5 Analog Input #1 9 Wiegand/RS232 Ground
6 LED Signal Input/Output 10 Auxiliary Digital Output
7 D1/DOUT Wiegand Data 1 Output 11 Digital Input
8 D0/COUT Wiegand Data 0 Output RLY 1 IN 12 Digital Input
RLY 1IN12
3 N.C. Contact
1 2 3 4 5 6 7 8
9 10 11
INS_EXP100_REV– 12/04/12 PAGE 2TECH SUPPORT: 1.888.678.9427
INSTALLATION AND OPERATION MANUAL EXP100
FIGURE 2 – EXP100/R REMOTE DATA EXTENDER
BLACK
BLACK& WHITE/RED
Power Supply: Input: 8–16 VDC @ 200mA Max Output: +5 VDC @ 100mA
18–16VDC
2GND
STATUS LED
1RS-485(+)
2RS-485(–)
EXP100/R
REMOTE
EXPANSION
MODULE
RLY1N.O. 4
RLY1COM5
RLY1N.C. 6
3+5VDC OUT 4 5 6LED OUT 7D1/DIN 8D0/CIN
Power Connections Relay Connections
1 - 8 – 16VDC Power IN (+) 1 N.O. Contact
2 - GND Power IN (–) 2 Common
3 N.C. Contact
Data Connections RLY 1 N.O. 4 N.O. Contact
1 RS-485(+) RS-485 Input RLY 1 COM 5 Common
2 RS-485(–) RS-485 Input RLY 1 N.C. 6 N.C. Contact
3 +5 VDC OUT 5V Power Out 7 RS232 Serial Data OUT
4 Analog Input #4 8 RS232 Serial Data IN
5 Analog Input #3 9 Wiegand/RS232 Ground
6 LED OUT LED Signal Output 10 Auxiliary Digital Input
7 D1/DIN Wiegand Data 1 Input 11 Not Used
8 D0/CIN Wiegand Data 0 Input 12 Not Used