Comnet eConsole500, eConsole250, eConsole100 User Manual

INSTALLATION AND OPERATION MANUAL
INDUSTRIAL ETHERNET PRODUCTS MANAGEMENT UTILITY SUITE
eConsole is ComNet’s powerful software monitoring and diagnostic utility. eConsole includes three separate utilities eCommander, eVision, and eMonitor. With the eCommander application the user can set parameters for multiple switches at the same time and it provides a powerful interface for users to manage all switches in the network.
eConsole is not only a powerful utility for users to configure but also a useful suite of utilities for monitoring. Users can monitor switches’ status via eMonitor. If the monitored switches fail, the failure information will be displayed on the Host monitoring interface.
The eVision application provides a real time overview of the entire network for visual fault indication and full monitoring capabilities for SNMP based traps.
Rev. 11.5.14
INSTALLATION AND OPERATION MANUAL ECONSOLE
Contents
Introduction 4
Regulatory Compliance Statement 4
Warranty 4
Disclaimer 4
System Requirements 5
Install eConsole 6
Configuring PC Network Interface Card 9
eCommander 10
Discover y 10
Task Menu 13
Settings Menu 14
Help 15
Icons Introduction 15
Devices list 16
LED and Port Status 16
Status Monitor 17
Scan Devices Configuration 18
Syslog Events 19
Wizards 19
Group IP Setting Wizard 19
Group Firmware Update Wizard 20
Group Configuration Backup 22
Group Configuration Restore 23
Group Redundant Ring Setting 24
TECH SUPPORT: 1.888.678.9427
INS_eConsole_REV– 12/20/12 PAGE 2
INSTALLATION AND OPERATION MANUAL ECONSOLE
eVision 25
About eVision 25
Topology Wizard 25
System Menu Bar 29
File 29
Edit 30
Device Database Management 32
View 33
Layout 33
Management 34
Help 34
Tool Bar 35
General 35
Topology Management 36
Map Management 37
Device Tree & Group Tree 38
Topology 39
Map 41
System Log Area 42
eMonitor 43
Add device 43
System Bar 44
File 44
Tool 4 4
About 45
Function Bar 45
Group Tree 46
Monitor Area 47
TroubleShooting 48
TECH SUPPORT: 1.888.678.9427
INS_eConsole_REV– 12/20/12 PAGE 3
INSTALLATION AND OPERATION MANUAL ECONSOLE
Introduction
Regulatory Compliance Statement
Product(s) associated with this publication complies/comply with all applicable regulations. Please refer to the Technical Specifications section for more details.
Warranty
ComNet warrants that all ComNet products are free from defects in material and workmanship for a specified warranty period from the invoice date for the life of the installation. ComNet will repair or replace products found by ComNet to be defective within this warranty period, with shipment expenses apportioned by ComNet and the distributor. This warranty does not cover product modifications or repairs done by persons other than ComNet-approved personnel, and this warranty does not apply to ComNet products that are misused, abused, improperly installed, or damaged by accidents.
Please refer to the Technical Specifications section for the actual warranty period(s) of the product(s) associated with this publication.
Disclaimer
Information in this publication is intended to be accurate. ComNet shall not be responsible for its use or infringements on third-parties as a result of its use. There may occasionally be unintentional errors on this publication. ComNet reserves the right to revise the contents of this publication without notice.
TECH SUPPORT: 1.888.678.9427
INS_eConsole_REV– 12/20/12 PAGE 4
INSTALLATION AND OPERATION MANUAL ECONSOLE
System Requirements
Minimum System Requirements
» Pentium(R) Dual-core 2.4 (or above)
» VGA Monitor with 1024 x 768 resolution (or above)
» 1 GB RAM (recommended 2GB and above)
» Java Runtime Environment 6 update 30 (or above)
» Internet Explorer 6.0 (or above)
» WinPcap 4.0 (or above)
Supported Network Protocols
» TCP / IP
» UDP
» SNMP
Operating System
» Windows 8
» Windows 7
» Windows Vista
» Windows XP/2000
» Windows Server 2008
» Windows Server 2003
Note: Please make sure your computer has Java Runtime Environment installed (if not, the
installer will ask if you would like to install it. You can also download the latest version of Java Runtime Environment (JRE) 7 from SUN at http://java.com/en/download/)
TECH SUPPORT: 1.888.678.9427
INS_eConsole_REV– 12/20/12 PAGE 5
INSTALLATION AND OPERATION MANUAL ECONSOLE
Install eConsole
Please see the following instructions to install the eConsole software
Step 1 – Obtain the latest copy of eConsole from the product information CD that accompanied
your switch or by visiting the website at www.comnet.net
eConsole Product Page on ComNet’s Website
Step 2 – Click on the eConsole EXE file to start the installation.
Step 3 – Click Next to install eConsole in the default directory or click Change to change the path
of installation. Then click Next to continue.
TECH SUPPORT: 1.888.678.9427
INS_eConsole_REV– 12/20/12 PAGE 6
INSTALLATION AND OPERATION MANUAL ECONSOLE
Step 4 – Accept the terms & conditions to continue with the install and click Next to continue.
Step 5 – The software will now be installed.
After the software has been installed new windows will pop up asking the user to install Java runtime environment 7 update 51 and WinPcap 4.1.3 which are requirements for eConsole to run properly. You can skip these installations if both of these programs are already installed on your machine.
TECH SUPPORT: 1.888.678.9427
INS_eConsole_REV– 12/20/12 PAGE 7
INSTALLATION AND OPERATION MANUAL ECONSOLE
Step 6 – Once the software installations have been completed a confirmation window will be
displayed. Click Ok to complete the install procedure.
After the installation is completed, shortcuts will be placed in the Start Menu in the following location: Start › All Programs › ComNet › eConsole
TECH SUPPORT: 1.888.678.9427
INS_eConsole_REV– 12/20/12 PAGE 8
INSTALLATION AND OPERATION MANUAL ECONSOLE
Configuring PC Network Interface Card
Please set the PC’s IP address and subnet mask to the same subnet as the switches that you wish to connect to.
If there are switches in different subnets the user will need to add in all subnets into the NIC using the Advanced menu option.
TECH SUPPORT: 1.888.678.9427
INS_eConsole_REV– 12/20/12 PAGE 9
INSTALLATION AND OPERATION MANUAL ECONSOLE
eCommander
eCommander can be used to discover and configure all ComNet second generation switches on the network. It also includes some useful wizards for fast switch configuration.
Note: Not all switches are compatible with eCommander. For a complete list of compatible
ComNet switch models please refer to the latest eConsole data sheet at www.comnet.net.
Discovery
The user can discover all the switches within the NIC subnet by simply clicking on the Discovery button.
TECH SUPPORT: 1.888.678.9427
INS_eConsole_REV– 12/20/12 PAGE 10
INSTALLATION AND OPERATION MANUAL ECONSOLE
Discovery Filter
In order to manage and discover switches in a different domain, the user can use the
Discovery Filter to search and add the switches.
Router
192.168.2.254 / 24192.168.10.254 / 24
192.168 .10.1 / 24
192.168.10.66 / 24
PC with
eConsole
Note: The gateway of the PC must be the Router.
Step 1 – Click the Discovery Filter button.
192.168 .2.1 / 24
192.168.2.3 / 24192.168.2.2 / 24
TECH SUPPORT: 1.888.678.9427
INS_eConsole_REV– 12/20/12 PAGE 11
INSTALLATION AND OPERATION MANUAL ECONSOLE
Step 2 – In the Remote section, enter the first remote IP and end remote IP range you need.
Click the + button to add in the IP range. A different subnet can also be added if needed. Then click the OK button.
The switches will be found and added into the device list of eCommander.
TECH SUPPORT: 1.888.678.9427
INS_eConsole_REV– 12/20/12 PAGE 12
INSTALLATION AND OPERATION MANUAL ECONSOLE
Task Menu
Label Description
Discovery Click Discovery to discover the switches on the same subnet as the PC. eCommander
will display all discovered switches on the management interface. eCommander discovers switches depending on the discovery filter.
Note: All switches can have the same IP address such as when they are delivered
from the factory. eCommander can discover and change the IP addresses by the Group IP Setting function.
Discovery Filter Local: eCommander will only discover all switches that are in the same specific IP
subnet of NIC that the user selects.
Remote: users are able to use specific IP address ranges to discover switches on
different subnets.
Login all eCommander can login to multiple switches that the user has selected. After login, the
switch icon will change from to
Note: By default, eCommander will logout of all switches automatically after
being idle for 300 seconds.
Logout all eCommander can logout from multiple switches that the user has selected. After logout
success, the switch icon will change from to .
Reboot eCommander can reboot multiple switches that the user has selected. When the user
clicks reboot, a dialog window will be displayed on screen to confirm.
Open Web eCommander will open the default browser of your OS automatically and navigate to
the selected switches web GUI.
Refresh Refresh the specific switches management interface and switch configuration interface.
Refresh All Refresh all switches management interfaces and switch configuration interfaces.
Clear state User can clear the device icon status.
TECH SUPPORT: 1.888.678.9427
INS_eConsole_REV– 12/20/12 PAGE 13
INSTALLATION AND OPERATION MANUAL ECONSOLE
Settings Menu
Label Description
Load Device Users are able to re-load the IP address list (The old list will be cleared).
Import Device Users are able to re-load the IP address list (The old list will remain and any new devices
will be added).
Save Device Users are able to save the IP address list on the Discovery Filter/Remote page.
Save Default Device
Users can save the device list as a default. On future starts eCommander will display the devices directly, without re-discovery.
Note: to use this function you must have enabled System Config menu › Load default device when start commander.
System Config Auto Logout time : Change the timer of the Auto logout.
Syslog server : Enable or disable eCommander’s built-in syslog server. Load default device when start commander : When eCommander starts it will
automatically read the last used device information
Note: to use this function you must also use the Settings menu › Save Default Device option.
Start minimize to system tray: Minimize the eCommander to the windows taskbar when
the eCommander is first started.
Run at Windows startup: Enable to run eCommander automatically at Windows startup Discover new devices without clearing device list: Enable to discover new devices
without clearing previous devices in the device list. State Banner: Enable to display the switch’s port state.
TECH SUPPORT: 1.888.678.9427
INS_eConsole_REV– 12/20/12 PAGE 14
INSTALLATION AND OPERATION MANUAL ECONSOLE
Help
Label Description
About Display eCommander version and build information.
Icons Introduction
The most commonly used functions are provided in the main icon bar so the user can use these function directly without the need to find them in menus.
Icon Description
Please refer to Task Menu section
Please refer to Task Menu section
Please refer to Task Menu section
Please refer to Task Menu section
eCommander will logout of the device automatically
Please refer to Task Menu section
Please refer to Task Menu section
Please refer to Task Menu section
Please refer to Task Menu section
eCommander Group IP Wizard can configure the IP Address of multiple switches. The function will be introduced in more detail in the eCommader Wizards section.
eCommander Group Firmware Wizard can update the firmware of multiple switches. The function will be introduced in more detail in the eCommader Wizards section.
TECH SUPPORT: 1.888.678.9427
eCommander Group Redundant Ring Wizard can set the C-Ring function of multiple switches. The function will be introduced in more detail in the eCommader Wizards section.
Please refer to the Help Menu section.