Comnet COMPAK15M2 User Manual

INSTALLATION AND OPERATION MANUAL
FVT/FVR15M2
VIDEO WITH RETURN DATA
The ComNet™ FVT/FVR15M2 series video and data transceiver supports the simultaneous transmission of video and return data over two multimode optical fibers. The module is universally compatible with all major CCTV camera manufacturers and supports RS232 and RS422 data interfaces and all major data protocols. Plug-and-play design ensures ease of installation and no electrical or optical adjustments are ever required.
Each transceiver incorporates a bi-color (Red/Green) indicating LED for monitoring proper system operation. See Figure 6 on Page 3 for LED Indicator explanations.
The FVT/FVR15M2 may be directly plugged into the ComNet Rack (Part C1) or may be either wall-mounted, rack-mounted, or DIN-rail mounted by the addition of ComNet model DINBKT1 adaptor plate. See Figure A on Page 4 for mounting instructions.
See Figures 1 – 6 for complete installation details.
INS_FVTFVR15M2_REV–
09/23/11
PAGE 1
INSTALLATION AND OPERATION MANUAL FVT/FVR15M2
FIGURE 1 – FVT/FVR15M2
MULTIMODE OR
SINGLE MODE
OPTICAL FIBER
BLACK BLACK WITH WHITE STRIPE/RED
Power Supply: Surface Mount: 8–15 VDC @ 250mA Rack Mount: From Rack
FIGURE 2 – FVT15M2 TRANSMITTER FIGURE 3 – FVR15M2 RECEIVER
REAR PANEL REAR PANELFRONT PANEL FRONT PANEL
TECH SUPPORT: 1.888.678.9427
NOTE: Remove Electrical Connector for Rack Mount Units
INS_FVTFVR15M2_REV–
09/23/11
PAGE 2
INSTALLATION AND OPERATION MANUAL FVT/FVR15M2
FIGURE 4 – DATA CONNECTIONS
TRANSMITTER RECEIVER
RS-232/RS-422
O
4 3 2 1
Manchester/Bi-phase
RS-232 OUT
GND
O
(+) DATA OUT
O
(-) DATA OUT
4 3 2 1
GND
O
(+) DATA OUT
O
(-) DATA OUT
FIGURE 5 – DATA SETTINGS
Customer
Equipment FVR15M2
RS-422
Manchester/ Bi-phase
RS-232/RS-422
3
O
2 1
3
O
Manchester/Bi-phase
O
2 1
O
(-) DATA IN
GND
(+) DATA IN
(-) DATA IN
GND
(+) DATA IN
RS-422
RS-232
Manchester/ Bi-phase
Customer
EquipmentFVT15M2
RS-232
RS-422
Bi-phase or
Manchester
Data Transmit
Signal Ground
Data Out (+)
Data Out (-)
Data Out (+)
Data Out (-)
FIGURE 6 – LED INDICATORS
VIDEO PRESENT TRANSMIT/RECEIVE DATA
GREEN Activity Activity
RED No Activity No Actvity
OFF Unit Powered Down
(+) DATA
GND
(+) DATA
(-) DATA
(+) DATA
(-) DATA
RS-232
GND
(+) DATA
(-) DATA
(+) DATA
(-) DATA
Data Receive
Signal Ground
Data In (+)
Data In (-)
Data In (+)
Data In (-)
TECH SUPPORT: 1.888.678.9427
INS_FVTFVR15M2_REV–
09/23/11
PAGE 3
MECHANICAL INSTALLATION INSTRUCTIONS
INSTALLATION CONSIDERATIONS
This fiber-optic link is supplied as a Standalone/Rack module. Units should be installed in dry locations protected from extremes of temperature and humidity.
C1-US, C1-EU, C1-AU OR C1-CH CARD CAGE RACKS
CAUTION: Although the units are hot-swappable and may be installed
without turning power off to the rack, ComNet recommends that the power supply be turned off and that the rack power supply is disconnected from any power source. Note: Remove electrical connector before installing in card cage rack.
1. Make sure that the card is oriented right side up, and slide it into the card guides in the rack until the edge connector at the back of the card seats in the corresponding slot in the rack’s connector panel. Seating may require thumb pressure on the top and bottom of the card’s front panel.
CAUTION: Take care not to press on any of the LEDs.
2. Tighten the two thumb screws on the card until the front panel of the card is seated against the front of the rack.
WARNING: Unit is to be used with a Listed Class 2 or LPS power supply rated 8-15
VDC @ 250 mA.
FIGURE A
Dimensions are for a standard ComNet one slot module
.156 [3.96 mm]
.313 [7.95 mm]
IMPORTANT SAFEGUARDS: A) Elevated Operating Ambient - If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is not compromised.