Comnet CLRFE1EOUE-M, CLRFE1EOUP-M User Manual

INSTALLATION AND OPERATION MANUAL
CLRFE1EOC(E,P)/M Series
MINI ETHERNET-OVER-COPPER EXTENDER REMOTE UNITS POWERED BY EXTERNAL OR POE SOURCE
This manual serves the following ComNet Model Numbers:
CLRFE1EOCE/M
CLRFE1EOCP/ M
The ComNet CopperLine® Ethernet-over-coax minis are an ultra-small form factor addition to the ComNet Copperline product family. These miniature remote units provide 10/100 Mbps Ethernet data with or without Pass-through PoE power over extended distance coaxial cable. Available in both standard and PoE applications, the mini CopperLine units are automatically configured as remote units.
Bi-color (Red/Green) LED indicators are provided for rapidly ascertaining equipment operating status. Table 3 on Page 4 describes the LED indicators for each light on the unit.
The mini CopperLine units are stand-alone with a small footprint for use where space is extremely limited. They may optionally be DIN-rail mounted by the addition of ComNet model DINBKT4 adaptor. See Figure A on Page 5 for mounting instructions.
INS_CLRFE1EOCX/M-REV- 12/23/14 PAGE 1TECH SUPPORT: 1.888.678.9427
INSTALLATION AND OPERATION MANUAL CLRFE1EOC(E,P)/M SERIES
FIGURE 1 – CLRFE1EOCE/M SINGLE CHANNEL COAX REMOTE EXTERNALLY POWERED UNIT
ETHERNET
EXT DISTANCE
FRONT
REAR
10/100 data rate DIP switch
See Installation Instructions, Step 1
Black (AC or DC–) Black w/ White
Stripe (AC or DC+)
Power: 9 to 36 VDC
OR 24 VAC
Power Consumption: 1.5 W
FIGURE 2 – CLRFE1EOCP/M SINGLE CHANNEL COAX REMOTE PASS-THROUGH-POE POWERED UNIT
EXT DISTANCE
10/100 data rate DIP switch
See Installation Instructions, Step 1
TECH SUPPORT: 1.888.678.9427
FRONT
ETHERNET
Power: Supplied via PoE
from Head End
Power Consumption: 1.5 W
REAR
INS_CLRFE1EOCX/M-REV- 12/23/14 PAGE 2
INSTALLATION AND OPERATION MANUAL CLRFE1EOC(E,P)/M SERIES
APPLICATION DIAGRAMS
Ethernet Connection
Extended Connection
PoE Power
PoE Pass-Through Mode
PoE
Ethernet Switch
or Midspan
Local Remote
CLFE1EOC CLRFE1EOCP/M
PoE Camera
Non-PoE Mode
Ethernet
Switch
IMPORTANT NOTE. PLEASE READ. The applications are shown as general representations only and are not intended to show detailed network topologies. Your actual network will differ, requiring changes or perhaps additional network equipment to accommodate the systems as illustrated. Please contact ComNet’s Design Center to discuss your specific requirements.
Local Remote
CLFE1EOC CLRFE1EOCE/M
Power Power Power
IP Camera
APPLICATION NOTES
1 Mixed PoE and Non-PoE systems can be implemented.
2 All Non-PoE systems require local power.
3 PoE powered operation requires that a PoE Camera be connected, and that the camera power requirements are understood.
4 Lower data rates generally provide longer operating distances.
TABLE 1 – APPROXIMATE MAXIMUM EXTENDED DISTANCES
1
Media COAX - RG59/U
Camera Data Rate
Non-PoE Camera
PoE CLASS2 Camera (6.5W)
1
1
PoE CLASS3 Camera(13W)1
(10W in Pass-Through mode)
1
Distance figures are based on a 50V PSE PoE power source, and external power supplies for the extenders. Distance figures are obtained using
in-house testing mirroring installations. Factors such as coaxial/copper cable quality, the number of connectors/splices in the cable run, the use of PoE, and environmental conditions encountered within the installation may affect the actual transmission distance, and should be taken into consideration. Due to advanced negotiation signaling required in IEEE 802.3at applications, Pass-through applications are limited to IEEE 802.3af PD devices only.
10M 100M
5,000 ft 1,524 m
3,000 ft
914 m
750 f t 228 m
2,000 ft
2,000 ft
610 m
610 m
750 f t 228 m
TECH SUPPORT: 1.888.678.9427
INS_CLRFE1EOCX/M-REV- 12/23/14 PAGE 3
INSTALLATION AND OPERATION MANUAL CLRFE1EOC(E,P)/M SERIES
INSTALLATION INSTRUCTIONS
1 - SET 10/100 SWITCH
Locate the 10/100 data rate DIP switch on the local unit. Set the data rate according to bandwidth required. The default setting for the data rate DIP switch is 100Mbps.
NOTE: The data rate must be set the same on both the local and remote units.
2 - SET LOCAL/REMOTE SWITCHES (1 AND 4 CHANNEL UNITS ONLY, FOR RACK UNITS SKIP TO STEP 4)
Locate the Local/Remote Dip switch and set to “LC” at the head end. Locate the Local/Remote push button switch, and set to the same setting as the dip switch. The CLRFE1EOCE/M and CRLFE1EOCP/M units are preconfigured as Remote devices.
4 - CONNECT EXTENDED WIRING
Connect Extended Distance Port to field wiring.
5 - CONNECT NETWORK WIRING
Using CAT5/5e, connect Local unit to network and Remote unit to camera.
6 - CONNECT POWER
Connect power to unit per the following table:
Table 2 – Power Connections per Use Case
Unit Power Requirement
CLRFE1EOCE/M
9 to 36 VDC or 18 to 32 VAC
Local External Power
CLRFE1EOCP/M
Contact ComNet pre-sales support, or refer to the appropriate installation and operation manual when configuring and specifying power for a deployment.
Provided from Head End CopperLine unit.
No external power required
7 - VERIFY FUNCTIONALITY
See LED table below and Troubleshooting Guide if corrective action is needed. See figures beginning on page 6 for LED configurations for each model.
Table 3 – Indicating LEDs
PWR Ethernet Link Ethernet Activity EXT LNK
GREEN Power Applied Activity Detected 10Mbps
YELLOW Link Established 100Mbps
OFF Power Off No Link No Activity No Link
Ethernet
Activity
Ethernet
Link
TABLE 4 – TROUBLESHOOTING GUIDE
Problem Steps to Take
Indicating LEDs not lighting Non-PoE: Check that power is properly applied to the unit
No Communication
Bad Video
PoE Not Supplied to PD Make sure camera is IEEE 802.3af rated, PoE Source switch is set properly, and the extended dis tance is within specifications
Units not reaching estimated max dist ances over COAX or CAT5/UTP
PoE: Check that PoE camera is connected, PoE source is enabled.
Check Ethernet Link LEDs, Ex tended Link LEDs, All Connections, Local/Remote and 10/100 switches are set properly.
Verify that Local
units are installed at the head end and that Remote units are installed in the field.
Make sure Data Rate Switch is set properly, and the extended distance is within specifications (see Table 1 – Approximate Maximum Extended Distances).
(see Table 1 – Approximate Maximum Extended Distances).
Check extended distance cable and connections. Try connection on a shor t cable to eliminate possibility of fault y cabling. Check that the ex tended distance wire is connec ted to Extended Dis tance Port. Verify that there is no additional equipment (e.g. surge protec tor) on the Extended Link. The cable should be continuous from end to end, with no ac tive components.
TECH SUPPORT: 1.888.678.9427
INS_CLRFE1EOCX/M-REV- 12/23/14 PAGE 4
INSTALLATION AND OPERATION MANUAL CLRFE1EOC(E,P)/M SERIES
INSTALLATION CONSIDERATIONS
The CLRFE1EOC(E,P)/M is supplied as a standalone/surface mount (mini size) module. Units should be installed in dry locations protected from extremes of
temperature and humidity.
WARNING: Unit is to be used with a Listed Class 2 power supply.
IMPORTANT SAFEGUARDS: A) Elevated Operating Ambient - If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (T
B) Reduced Air Flow - Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is not compromised.
) specified by the manufacturer.
ma
FIGURE A
Dimensions are for a mini size module
3 CORPORATE DRIVE
8 TURNBERRY PARK ROAD
© 2016 Communicat ion Network s. All Rights R eserved. “C omNet,” the “Com Net Logo,” “Copper Line,” and the “C opperLine Log o” are register ed trademark s of Communicat ion Network s.
|
DANBURY, CONNECTICUT 06810
|