Comnet CLFE1UTP, CLFE4UTP, CLFE8UTP, CLFE16UTP Installation And Operation Manual

INSTALLATION AND OPERATION MANUAL
CLFE(X)UTP
ETHERNET-OVER-UTP/TWISTED PAIR EXTENDER WITH PASS-THROUGH POE
Important Safety Warning:
Read and keep these directions
Heed all warnings
Follow all instructions
Do not use this apparatus near water
Clean only with a dry cloth
Install in accordance with the manufacturer’s instructions
This installation should be made by a qualified service person and should conform to all local codes
See further safety instructions on Page 8
The ComNet™ CopperLine® CLFE(X)UTP Ethernet over UTP line consists of four models that support 100Mbps Ethernet as well as Pass-through Power over Ethernet (PoE) over twisted pair cable (CAT5, UTP). These models support transmission distances of up to 3,000 feet (914m) at 10 Mbps, or 2,100 feet (640m) at 100 Mbps. The CLFE1UTP, the CLFE4UTP, CLFE8UTP and the CLFE16UTP transport, one, four, eight or sixteen channels respectively. The IEEE 802.3-compliant Ethernet electrical interface of these Ethernet extenders also meets the requirements for IEEE 802.3af PoE power, passing-through up to 30 watts of power per port to the powered device (PD). The CLFE(X)UTP series may also be used interchangeably with other CopperLine Ethernet-over-UTP extenders.
Environmentally hardened to the requirements of NEMA TS-1/ TS-2 for most out-of­plant applications, and true plug-and-play design ensures ease of installation and operation.
LED indicators are provided for rapidly ascertaining the operating status of the device. See Figures 6 – 8 on Page 7 for LED explanations.
Packaged in a rugged aluminum housing, these units are designed for desktop or stand­alone mounting. The CLFE8UTP and CLFE16UTP are offered in EIA 19” 1U high rack for easy installation. See Figures A through C on Page 8 for mounting instructions.
See Figures 1 – 8 for complete installation details.
INS_CLFEXUTP_REV–
09/28/11
PAGE 1
INSTALLATION AND OPERATION MANUAL CLFE(X)UTP
FIGURE 1 – CLFE1UTP
CAT5/6
UTP
FIGURE 2 – CLFE1UTP
2 1
For 1-pair mode, use the first pair of pins (pins 1 & 2) of the “Extended Ethernet” RJ-45 port on the left panel. Note: 4-pair mode is required for PoE.
Ground
Screw*
CAT5/6
POWER SUPPLY
CONNECTION
+
via external power adaptor
Optional, if there is no power supply connected to the unit it will try to detect PoE.
RIGHT PANELLEFT PANEL
Note: Center pin on power connector is positive (+).
* WARNING: A ground connection is
required for the surge protection to work. Failure to ground properly voids the warranty and may cause damage.
FIGURE 3 – CLFE4UTP
LEFT PANEL RIGHT PANEL
CAT5/6 or UTP
CAT5/6
TECH SUPPORT: 1.888.678.9427
Ground
Screw*
* WARNING: A ground connection is
required for the surge protection to work. Failure to ground properly voids the warranty and may cause damage.
INS_CLFEXUTP_REV–
09/28/11
PAGE 2
INSTALLATION AND OPERATION MANUAL CLFE(X)UTP
PASS-THROUGH PoE OPERATIONS FOR THE CLFE1UTP
ComNet’s CopperLine CLFE1UTP extended distance IP data and PoE maintains the safety standards for communications found within the 802.3af PoE standards. This is for the protection of products operating in the extended distance transmission chain. In the
event of malfunctions the communication system is designed to shut down power transmission to avoid device damage.
The CLFE1UTP can be powered by a local power source (12 Volts D.C. or 24 Volts A.C.) or from a single PSE source, such as a network switch’s PoE port using its unique Pass-through PoE feature (4-pair mode only). This latter feature eliminates the need for CLFE1UTP local power while also providing power for the camera (See full installation instructions, Page 6).
Powering The CLFE1UTP Transceivers
Input with external power plug installed.
Under normal operating conditions CLFE1UTP transceivers should be powered using the PoE source. External power to the CLFE1UTP should be restricted to installations where a camera requires local power.
When installing the CLFE1UTP, the following conditions apply which will affect its operations.
The CLFE1UTP is provided with the ability to operate using a local external power supply. The standard accessory local power adaptor plug can be used for power supplies that do not have the CLFE1UTP’s standard power input connector. When inserting the adaptor into the power input, the CLFE1UTP is only powered from a local power source and not from a PSE source. The camera will continue receiving power from the PSE source and operations will be normal.
However, if the external plug adaptor is inserted in the CLFE1UTP and no power is applied, the CLFE1UTP will not power up even if a PoE source is present, the camera will continue to receive power. In this case the CLFE1UTP is not operational and no data will flow.
If the CLFE1UTP is externally powered and PSE power is lost, power to the CLFE1UTP must be recycled in order for the PSE to recognize the PD (Camera).
External power adapter (included)
TECH SUPPORT: 1.888.678.9427
INS_CLFEXUTP_REV–
09/28/11
PAGE 3