This document has been developed by CommScope, and is intended for the use of its
customers and customer support personnel. The information in this document is subject to
change without notice. While every effort has been made to eliminate errors, CommScope
disclaims liability for any difficulties arising from the interpretation of the information
contained herein. The information contained herein does not claim to cover all details or
variations in equipment, nor to provide for every possible incident to be met in connection
with installation, operation, or maintenance. This document describes the performance of the
product under the defined operational conditions and does not cover the performance under
adverse or disturbed conditions. Should further information be desired, or should particular
problems arise which are not covered sufficiently for the purchaser’s purposes, contact
CommScope.
CommScope reserves the right to change all hardware and software characteristics without
notice.
This document is protected by copyright. No part of this document may be reproduced,
stored in a retrieval system, or transmitted, in any form or by any means, electronic,
mechanical photocopying, recording, or otherwise without the prior written permission of
CommScope.
TRADEMARKS
All trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of
CommScope. Names of products mentioned herein are used for identification purposes only
and may be trademarks and / or registered trademarks of their respective companies.
Andrew Wireless Systems GmbH, 28-January-2016
Page 2 MF0150A3A.doc Manual for ION-M7P/17EHP
Table of Contents
TABLE OF CONTENTS
1. GENERAL 5
1.1.USED ABBREVIATIONS 5
1.2.HEALTH AND SAFETY 6
1.3.PROPERTY DAMAGE WARNINGS 6
1.4.COMPLIANCE 7
1.5.ABOUT COMMSCOPE 9
1.6.INTERNATIONAL CONTACT ADDRESSES FOR CUSTOMER SUPPORT 10
2. INTRODUCTION 12
2.1.PURPOSE 12
2.2.THE ION-M7P/17EHP 12
3. FUNCTIONAL DESCRIPTION 13
3.1.ACCESSORY EQUIPMENT 13
3.1.1.Fan-Protection Kit 13
3.1.2.Accessories 13
4. COMMISSIONING 14
4.1.MECHANICAL INSTALLATION 14
4.1.1.Health and Safety for Mechanical Installation 14
4.1.2.Property Damage Warnings for Mechanical Installation 14
4.1.3.Wall-Mounting Procedure 16
4.1.4.Pole Mounting 17
4.1.5.Mounting of Fan Protection 19
4.2.ELECTRICAL INSTALLATION 20
4.2.1.Health and Safety for Electrical Installation 20
4.2.2.Property Damage Warnings for Electrical Installation 20
4.2.3.Connections 21
4.2.4.Grounding (Earthing) 21
4.2.5.Connection of the Antenna Cables 22
4.2.6.Cleaning Procedure for RF Cable Connectors 23
4.2.7.Antenna Cable Connector Assembly 26
4.2.8.Optical-Fiber-Cable Connection - Rules 27
4.2.9.Protective Plug 29
4.2.10.Protective-Tube Kit 31
4.2.11.External-Alarm Inputs and Outputs 33
4.2.12.Power Connection 35
4.2.13.Commisioning Flowchart 36
5. ALARMS AND TROUBLESHOOTING 38
MF0150A3A.doc Manual for ION-M7P/17EHP Page 3
Figures and Tables
MAINTENANCE 39
6.
6.1.GENERAL 39
6.2.REPLACING THE FAN UNIT 40
6.3.CLEANING THE HEAT SINK 41
7. APPENDIX 42
7.1.ILLUSTRATIONS 42
7.2.SPECIFICATIONS 43
7.2.1.SW Requirements 43
7.2.2.Electrical Specifications 43
7.2.3.Mechanical Specifications 43
7.2.4.Environmental and Safety Specifications 43
table 5-1 Status LED alarms ....................................................................................... 38
Page 4 MF0150A3A.doc Manual for ION-M7P/17EHP
1. General
1. General
1.1. Used Abbreviations
3GPP 3rd Generation Partnership Project
AC/DC Alternating current / Direct Current
AIMOS Andrew Integrated Management and Operating System
ALC Automatic Level Control
BITE Built-In Test Equipment
BTS Base Transceiver Station
CE "Conformité Européenne" ("European Conformity")
CD Compact Disk
CFR Code of Federal Regulations
DL Downlink
DoC Declaration of Conformity
EDGE Enhanced Data Rates for GSM Evolution
EN European Norm
ESD Electrostatic Discharge
ETS European Telecommunication Standard
GSM Global System for Mobile Communication
GND Ground
GUI Graphical User Interface
ICP3 Intercept Point 3rd order
ID No Identification Number
ION Intelligent Optical Network
IP Ingress Protection
ISO International Organization for Standardization
LED Light Emitting Diode
LMT Local Maintenance Terminal
LTE Long Term Evolution
MIMO Multiple Input Multiple Output
MS Mobile Station
MU Main Unit
1. Danger: Electrical hazard. Danger of death or fatal injury from electrical
current. Obey all general and regional installation and safety regulations
relating to work on high voltage installations, as well as regulations
covering correct use of tools and personal protective equipment.
2. Danger: Electrical hazard. Danger of death or fatal injury from electrical
current inside the unit in operation. Before opening the unit, disconnect
mains power.
3. Caution: Laser radiation. Risk of eye injury in operation. Do not stare into the
beam; do not view it directly or with optical instruments.
4. Caution: High frequency radiation in operation. Risk of health hazards associated
with radiation from the unit’s inner conductor of the antenna port(s). Disconnect
mains before connecting or replacing antenna cables.
5. Caution: High frequency radiation in operation. Risk of health hazards associated
with radiation from the antenna(s) connected to the unit. Implement prevention
measures to avoid the possibility of close proximity to the antenna(s) while in
operation.
1.3. Property Damage Warnings
1. Attention: Due to power dissipation, the remote unit may reach a very high
temperature. Do not operate this equipment on or close to flammable materials.
Use caution when servicing the unit.
2. Attention: Only authorized and trained personnel are allowed to open the unit
and get access to the inside.
3. Notice: Although the Remote Unit is internally protected against overvoltage, it is
strongly recommended to ground (earth) the antenna cables close to the antenna
connectors of the Remote Unit for protection against atmospheric discharge. In
areas with strong lightning, it is strongly recommended to install additional
lightning protection.
4. Notice: ESD precautions must be observed. Before commencing maintenance
work, use the available grounding (earthing) system to connect ESD protection
measures.
5. Notice: Only suitably qualified personnel are allowed to work on this unit and only
after becoming familiar with all safety notices, installation, operation and
maintenance procedures contained in this manual.
6. Notice: Keep operating instructions within easy reach and make them available
to all users.
Page 6 MF0150A3A.doc Manual for ION-M7P/17EHP
1. General
7. Notice: Read and obey all the warning labels attached to the unit. Make sure that
all warning labels are kept in a legible condition. Replace any missing or
damaged labels.
8. Notice: Only license holders for the respective frequency range are allowed to
operate this unit.
9. Notice: Make sure the repeater settings are correct for the intended use (refer to
the manufacturer product information) and regulatory requirements are met. Do
not carry out any modifications or fit any spare parts, which are not sold or
recommended by the manufacturer.
1.4. Compliance
1. Notice: For installations, which have to comply with FCC RF exposure
requirements, the antenna selection and installation must be completed in a way
to ensure compliance with those FCC requirements. Depending on the RF
frequency, rated output power, antenna gain, and the loss between the repeater
and antenna, the minimum distance D to be maintained between the antenna
location and human beings is calculated according to this formula:
P
][
D
][
cm
4
mW
PD
2
]/[
cmmW
where
P (mW) is the radiated power at the antenna, i.e. the max. rated repeater
output power in addition to the antenna gain minus the loss between the
repeater and the antenna.
PD (mW/cm²) is the allowed Power Density limit acc. to 47 CFR 1.1310 (B)
for general population / uncontrolled exposures which is
o F (MHz) / 1500 for frequencies from 300MHz to 1500MHz
o 1 for frequencies from 1500MHz to 100,000MHz
RF exposure compliance may need to be addressed at the time of licensing, as
required by the responsible FCC Bureau(s), including antenna co-location
requirements of 1.1307(b)(3).
2. Notice: For installations which have to comply with European EN50385 exposure
compliance requirements, the following Power Density limits/guidelines (mW/cm²)
according to ICNIRP are valid:
o 0.2 for frequencies from 10 MHz to 400 MHz
o F (MHz) / 2000 for frequencies from 400 MHz to 2 GHz
o 1 for frequencies from 2 GHz to 300 GHz
MF0150A3A.doc Manual for ION-M7P/17EHP Page 7
1. General
3. Notice: Installation of this equipment is in full responsibility of the installer, who
has also the responsibility, that cables and couplers are calculated into the
maximum gain of the antennas, so that this value, which is filed in the FCC Grant
and can be requested from the FCC data base, is not exceeded. The industrial
boosters are shipped only as a naked booster without any installation devices or
antennas as it needs for professional installation.
4. Notice: The unit complies with Overvoltage Category II. It also complies with the
surge requirement according to EN 61000-4-5 (fine protection); however,
installation of an additional medium (via local supply connection) and/or coarse
protection (external surge protection) is recommended depending on the
individual application in order to avoid damage caused by overcurrent.
For Canada and US, components used to reduce the Overvoltage Category shall
comply with the requirements of IEC 61643-series. As an alternative, components
used to reduce the Overvoltage Category may comply with ANSI/IEEE C62.11,
CSA Certification Notice No. 516, CSA C22.2 No. 1, or UL 1449. Suitability of the
component for the application shall be determined for the intended installation.
5. Notice: Corresponding local particularities and regulations must be observed. For
national deviations, please refer to the respective documents included in the
manual CD that is delivered with the unit.
6. Note: This unit complies with European standard EN60950.
Equipment Symbols Used / Compliance
Please observe the meanings of the following symbols used in our equipment and
the compliance warnings:
Symbol Compliance Meaning / Warning
For industrial (Part 20) signal booster:
WARNING: This is NOT a CONSUMER device. It is
designed for installation by FCC LICENSEES and
--- FCC
QUALIFIED INSTALLERS. You MUST have an FCC
LICENSE or express consent of an FCC Licensee to
operate this device. Unauthorized use may result in
significant forfeiture penalties, including penalties in
excess of $100,000 for each continuing violation.
Alert sign to R&TTE
To be sold exclusively to mobile operators or
authorized installers – no harmonized frequency
CE
bands, operation requires license. Intended use: EU
and EFTA countries.
Indicates conformity with the R&TTE directive
1999/5/EC certified by the notified body no. 0700.
Page 8 MF0150A3A.doc Manual for ION-M7P/17EHP
1. General
1.5. About CommScope
CommScope is the foremost supplier of one-stop, end-to-end radio frequency (RF)
solutions. Part of the CommScope portfolio are complete solutions for wireless
infrastructure from top-of-the-tower base station antennas to cable systems and
cabinets, RF site solutions, signal distribution, and network optimization. For patents
see www.cs-pat.com.
CommScope has global engineering and manufacturing facilities. In addition, it
maintains field engineering offices throughout the world.
Andrew Wireless Systems GmbH based in Buchdorf/Germany, which is part of
CommScope, is a leading manufacturer of coverage equipment for mobile radio
networks, specializing in high performance, RF and optical repeaters. Our optical
distributed networks and RF repeater systems provide coverage and capacity
solution for wireless networks in both indoor installations and outdoor environments,
e.g. tunnels, subways, in-trains, airport buildings, stadiums, skyscrapers, shopping
malls, hotels and conference rooms.
Andrew Wireless Systems GmbH operates a quality management system in
compliance with the requirements of ISO 9001 and TL 9000. All equipment is
manufactured using highly reliable material. To maintain highest quality of the
products, comprehensive quality monitoring is conducted at all fabrication stages.
Finished products leave the factory only after a thorough final acceptance test,
accompanied by a test certificate guaranteeing optimal operation.
This product meets the requirements of the R&TTE directive and the Declaration of
Conformity (DoC) itself. A current version of the CE DoC is included in this manual
CD delivered *. Any updated version of the DoC is available upon request from the
local sales offices or directly from CommScope via the local Customer Support at
one of the addresses listed in the following chapter.
According to the DoC, our "CE"-marked equipment can be used in all member
states of the European Union.
Note: Exceptions of and national deviations from this intended use may be
possible. To observe corresponding local particularities and
regulations, please refer to the respective documents (also in
national language) which are included in the manual CD delivered.
* In case the Declaration of Conformity (DoC) for the product was not included in the manual CD
delivered, it is available upon request from the local sales offices or directly from CommSc ope at one of the addresses listed in the following chapter.
To make the most of this product, we recommend you carefully read the instructions
in this manual and commission the system only according to these instructions.
For technical assistance and support, please also contact the local office or
CommScope directly at one of the addresses listed in the following chapter.
MF0150A3A.doc Manual for ION-M7P/17EHP Page 9
A
(
A
A
1. General
1.6. International Contact Addresses for Customer Support
Fishponds Road
Wokingham Berkshire
RG41 2GY, England
Germany France
Andrew Wireless Systems GmbHCommScope France
Industriering 10
86675 Buchdorf
Germany
Mail
Mail
E
U
R
O
Austria Switzerland
Weglgasse 10
2320 Wien-Schwechat
Austria
Italy Iberia Region - Spain & Portugal
CommScope Italy S.r.l., Faenza, Italy
Via Mengolina, 20
48018 Faenza (RA)
Italy
Czech Republic
CommScope Solutions Czech Republic
C-Com, spol. s r.o
U Moruší 888
53006 Pardubice, Czech Republic
+49 871 9659171 (Office)
+49 171 4001166 (Mobile)
P
E
Mail
ndrew España S.A.A CommScope Company
Mail
Scandinavia
ndrew Norway (AMNW)
P.O. Box 3066
Osloveien 10
Hoenefoss 3501
Norway
Immeuble Le Lavoisier
4, Place des Vosges
92052 Courbevoie, France
Tiergartenweg 1
CH-4710 Balsthal
Switzerland
Avda. de Europa, 4 - 2ª pta.
Parque Empresarial de la Moraleja
Alcobendas, Madrid 28108, Spain
table 1-1 List of international contact addresses
MF0150A3A.doc Manual for ION-M7P/17EHP Page 11
2. Introduction
2. Introduction
2.1. Purpose
Cellular telephone systems transmit signals in two directions between base
transceiver station (BTS) and mobile stations (MS) within the signal coverage area.
If weak signal transmissions occur within the coverage area because of indoor
applications, topological conditions or distance from the transmitter, extension of the
transmission range can be achieved by means of an optical distribution system.
Such a system contains an optical Master Unit and several Remote Units. The
number of the Remote Units depends on the hardware and software configuration.
The Remote Units are connected to the Master Unit with optical links. The optical
loss must be less than 10 dB inclusive optical couplers or splitters.
The Master Unit is the connection to the base transceiver stations. The configuration
of a Master Unit depends on the number of the Remote Units and the frequency
range.
WDM (Wave Division Multiplex) filters are integrated in the optical modules. For the
UL, a wavelength within 1546 nm – 1550 nm is used. For the DL, a wavelength of
1310 ± 10 nm is used. The maximum output power for the UL and DL is 6.7 mW.
2.2. The ION-M7P/17EHP
The ION-M7P/17EHP is a multi-band, multi-operator remote unit configuration used
in conjunction with a Master Unit in the ION optical distribution system. By supporting
the entire AWS-3 spectrum, faster and more reliable wireless service is ensured and
network quality can be improved.
This system transports up to two frequency bands simultaneously (700 MHz and
1700/2100 MHz), providing a cost-effective solution for distributing capacity from one
or more base stations.
The ION system transports signals on the RF layer in a very cost-effective manner
enabling multiple operators to use multiple technologies and move their signals
simultaneously from a cluster of base station to a number of remote locations over
the same fiber.
The ION-M optical distribution system is a cost-effective coverage solution for dense
urban areas, tunnels, subways, airports, convention centers, high-rise buildings and
other locations where physical structures increase path loss.
Page 12 MF0150A3A.doc Manual for ION-M7P/17EHP
3. Functional Description
The combination of these units gives maximum flexibility while providing a scalable
solution. The system is optimized for LTE, WCDMA, and CDMA signals in the 700
MHz and 1700/2100 MHz bands. Furthermore it is provisioned for future modulation
schemes and frequency bands.
The ION can be easily set-up and supervised from a graphical user interface (GUI).
Remote units are commissioned through the use of built-in test equipment. An auto
levelling function compensates for the optical link loss making installation easy and
quick.
The entire system as well as complete network of systems can be managed remotely
most efficiently by Commscope`s A.I.M.O.S, which includes alarm monitoring, task
automation, statistics, inventory management and many more features. Should a
sophisticated interface not be required, the master unit can be directly connected to
the alarm interface of a base station via its contact relay.
Features at a glance
Reduced visual impact form factor
Optimized power consumption
Efficient, high power amplifier
Multi-operator support
Complete operations and management system for configuration and alarming
OMC with SNMP according to X.733 standard
With reference to 3GPP TS25.143/TS25.106/36.143/TS36.106 and
3GPP2C.S0051-0
Single fiber for multiple bands and multiple remotes
Easy installation and commissioning
3. Functional Description
3.1. Accessory Equipment
3.1.1. Fan-Protection Kit
In order to protect the fan unit (e.g. against rain), a protective cover to be mounted
over the air inlet is delivered with the unit. For more details see section 4.1.5
Mounting of Fan Protection.
Mounting of the fan-protection kit is only mandatory for outdoor applications,
however, not mandatory for indoor applications.
3.1.2. Accessories
For the accessories available for the Remote Unit, e.g. overcoat housing, connecting
box or iso-trafo kit, a separate manual is available.
MF0150A3A.doc Manual for ION-M7P/17EHP Page 13
4. Commissioning
4. Commissioning
Read and observe the health, safety, and property damage warnings as well as the
description carefully to avoid mistakes and proceed step-by-step as described.
Attention: Do not operate the Remote Unit without terminating the antenna
connectors. The antenna connectors may be terminated by connecting them
to their respective antennas or to a dummy load.
Notice: Only qualified personnel should carry out the electrical, mechanical,
commissioning, and maintenance activities that require the unit to be powered
on when open.
When opening the Remote Unit do not damage the warranty labels on the
internal devices. The warranty is void if the seals are broken.
Unless otherwise agreed to in writing by CommScope, CommScope’s general limited
product warranty (http://www.commscope.com/Resources/Warranties/) shall be the
warranty governing the Remote Units, including the installation, maintenance, usage
and operation of the Remote Units.
4.1. Mechanical Installation
4.1.1. Health and Safety for Mechanical Installation
1. Caution: Risk of injury by the considerable weight of the unit falling. Ensure there is adequate manpower to handle the weight of the system.
2. Caution: Risk of serious personal injury by equipment falling due to improper
installation. The installer must verify that the supporting surface will safely
support the combined load of the electronic equipment and all attached hardware
and components. The screws and dowels (wall anchors) used should also be
appropriate for the structure of the supporting wall.
4.1.2. Property Damage Warnings for Mechanical Installation
1. Attention: Do not install the unit in a way or at a place where the specifications
outlined in the Environmental and Safety Specifications leaflet of the supplier are
not met.
2. Attention: Due to power dissipation, the Remote Unit may reach a very high
temperature. Ensure sufficient airflow for ventilation.
3. Notice: Exceeding the specified load limits may cause the loss of warranty.
4. Notice: When connecting and mounting the cables (RF, optical, mains, ...) ensure that no water can penetrate into the unit through these cables.
5. Notice: Also observe all additional rules or restrictions regarding mounting that
depend on the type of Remote Unit. For details refer to section 7.2.2 Mechanical
Specification. Install the unit vertically with the fan unit at the top. A maximum tilt
angle of 25° from a vertical position must be kept, as in the following illustrations:
Page 14 MF0150A3A.doc Manual for ION-M7P/17EHP
4. Commissioning
6. Notice: A spacing of 40 mm (1.58 inch) around the unit is required.
7. Notice: To ensure sufficient airflow when mounting the unit in enclosed spaces,
two lid openings (one for the air inlet and the other for the air outlet) must be
provided. Do not block these air inlets and outlets when mounting the Remote
Unit. The size of each opening must equal at least 16 x 16 cm (>250 cm
2
).
Ensure that there is no thermal short circuit between the air inlet and air outlet.
Make sure free airflow is not deflected or otherwise obstructed.
8. Notice: Depending on the installation type (wall or pole), the corresponding
mounting kits must be ordered from the manufacturer. If any different or
additional mounting material is used, ensure that the mounting remains as safe
as the mounting designed by the manufacturer. The specifications for stationary
use of the Remote Unit must not be exceeded. Ensure that the static and
dynamic strengths are adequate for the environmental conditions of the site. The
mounting itself must not vibrate, swing or move in any way that might cause
damage to the Remote Unit.
9. Notice: To avoid damage when mounting the unit, always make sure that the M8
washers (DIN9021 or DIN125 depending on the mounting kit) are placed behind
and in front of the mounting drillings of the unit.
Specified torques have to be observed for certain mounting procedures according to
the following table:
Type
Thread
Specified torques
Tallow-drop
screws
M 4 M 8 M 4 M 8 PG 13.5 PG 29
3.3 N-m 27 N-m 2.3 N-m 27 N-m 3.75 N-m 10 N-m
Hex
nuts
Spacing
bolts
PG
(plastic)
PG
(aluminium)
table 4-1 Specified torques
The mounting procedures for a stand-alone Remote Unit without optional
accessories are described and illustrated in the following sections. For further
information regarding special mounting procedures including mounting of accessory
equipment, please see separate manual.
MF0150A3A.doc Manual for ION-M7P/17EHP Page 15
4.1.3. Wall-Mounting Procedure
Check the suitability of the wall-mounting kit and the wall.
Mark the position of the drilling
holes (for measurements refer to
figure 4-1 Wall mounting). Drill
four holes at the marked positions
and insert dowels *.
Use a cap nut or lock nut to screw
the four dowel screws into the
dowels and put the distance tubes
over the screws.
Hang the mounting brackets of the
Remote Unit into the screws, and
fasten them immediately using the
washers and nuts.
Ensure that there is free access to
the electrical connections as well
as to the cabinet. The approved
bending radius of the connected
cables must not be exceeded.
4.0 0.50
Wall mounting with active cooling kit
4
Mains supply
4. Commissioning
122 ± 0.50
80 ± 0.50
9
796 ± 1.00
18
G0946Z0
* The dowels are not part of the delivery since the suitable type depends on the on-site conditions
(material of wall). Therefore, use dowels that are appropriate for the mounting surface.
figure 4-1 Wall mounting, (metric dimensions)
Page 16 MF0150A3A.doc Manual for ION-M7P/17EHP
4. Commissioning
4.1.4. Pole Mounting
Standard mounting hardware cannot be used to mount the Remote Unit to a pole, a
column or other similar structures. Additional hardware must be used for this type of
installation. Such a pole-mounting kit could include two threaded rods M8, two
U-beams and mounting material like bolts and nuts.
figure 4-2 Pole-mounting kit
Use the screw bands to fasten the two U-beams to the pole as illustrated in figure
4-3 Pole mounting.
Note: When fastening the U-beams make sure that they are installed
congruently and not at an angle to each other. To determine the distance
between the beams refer to chapter 4.1.3 Wall-Mounting Procedure for
measurements.
Hang the mounting brackets of the Remote Unit into the threaded bolts of the
U-beam, and fasten them immediately using the washers and nuts.
Ensure that there is free access to the electrical connections as well as to the
cabinet. The approved bending radius of the connected cables must not be
exceeded.
MF0150A3A.doc Manual for ION-M7P/17EHP Page 17
Lock for folding
screw band ES 119
TESPA screw band,
stainless, 11 mm
0
4
1
Ø
Optical
Remote Unit
Washer DIN 125
Form B Ø 8.0
4. Commissioning
Lock washer for M8.0 DIN 127
A2 Form B
Hexagon nut M8
DIN 934
0
4
Ø
Pole
Pole-mounting
bracket
Pole
G0764M6
figure 4-3 Pole mounting (metric dimensions)
Page 18 MF0150A3A.doc Manual for ION-M7P/17EHP
4. Commissioning
4.1.5. Mounting of Fan Protection
Since the fan protection is required for the outdoor usage of a stand-alone Remote
Unit, the mounting of this optional equipment is also described in this manual.
To install the protective cover of the fan protection kit, first unscrew the four
screws with the respective lock washers from the cover of the air inlet of the
Remote Unit, and instead, screw in the four spacing bolts M4.0x30 with the four
lock washers M4.0 DIN125 that are part of the fan protection kit.
Place the protective cover into the right position by fitting its four bore holes over
the spacing bolts and fasten it using the original lock washers and screws of the
Remote Unit. (These lock washers and screws are also part of the fan protection
kit and can be used as spare parts in case of loss.)
figure 4-4 Mounting procedure for fan protection, (metric dimensions)
This figure shows the long version of the RU. For dimensions of the short
version, see Mechanical Specifications in chapter 7.2.3 or figure 7 3.
MF0150A3A.doc Manual for ION-M7P/17EHP Page 19
4. Commissioning
4.2. Electrical Installation
4.2.1. Health and Safety for Electrical Installation
Read and observe chapter 1.2 Health and Safety.
Danger: Electrical hazard. Danger of death or fatal injury from electrical
current. Obey all general and regional installation and safety regulations
relating to work on high voltage installations, as well as regulations
covering correct use of tools and personal protective equipment.
4.2.2. Property Damage Warnings for Electrical Installation
1. Attention: It is compulsory to ground (earth) the unit before connecting the
power supply. Grounding bolts are provided on the cabinet to connect the
ground-bonding cable.
2. Attention: If the mains connector of the Remote Unit is not easily accessible, a
disconnect device in the mains power circuit must be provided within easy reach.
3. Attention: A connection of the mains supply to a power socket requires the
power socket to be nearby the Remote Unit.
4. Attention: Before connecting or disconnecting the mains connector at the
Remote Unit, ensure that mains power supply is disconnected.
5. Attention: Make sure that an appropriate circuit breaker acting as a disconnect
device (as required by IEC/EN60950-1) and an overcurrent limiting device are
connected between mains power and the Remote Unit.
6. Attention: Incorrectly wired connections can destroy electrical and electronic
components.
7. Notice: To avoid corrosion at the connectors caused by electrochemical
processes, the material of the cable connectors must not cause a higher potential
difference than 0.6 V (see electrochemical contact series).
8. Notice: Use an appropriate torque wrench for the coupling torques:
- for N-type connectors (2 N-m / 20 in lb) with 13/16 in opening,
e. g. item no. 244379 available from the CommScope e-catalog
- for 7/16 DIN-type (25 N-m / 19 ft lb) with 1 ¼ in opening,
e. g. item no. 244377 available from the CommScope e-catalog
Do NOT use your hands or any other tool (e.g. a pair of pliers). This might
cause damage to the connector and lead to a malfunction of the Remote Unit.
9. Notice: For unstabilized electric networks, which frequently generate spikes, the
10. Notice: Observe the labels on the front panels before connecting or
disconnecting any cables.
11. Notice: Unused connectors must be closed with their protective covers to ensure
watertightness.
Page 20 MF0150A3A.doc Manual for ION-M7P/17EHP
4. Commissioning
p
(
)
4.2.3. Connections
Mains
connector
Grounding
Status LED External alarm in
RS485 connector
not required for operation
ut
Alarm
output
Opticalfibre
connector
N-antenna connector LTE700
N-antenna connector AWS
figure 4-5 Connector flange of ION-M7P/17EHP
4.2.4. Grounding (Earthing)
Grounding must be carried out. Connect an earth-bonding cable to the grounding
connection provided at the outside of the Remote Unit (see section 4.2.3). Do not use
the grounding connection to connect external devices.
figure 4-6 Grounding bolt (left) and schematic view (right)
MF0150A3A.doc Manual for ION-M7P/17EHP Page 21
After loosening the hex nut, connect the earth-bonding cable between the two
washers as illustrated in the above. Then, fasten all parts again with the hex nut.
4. Commissioning
Note: Ground of a second unit (for example RU + EU) has to be connected to
the same equipotential bonding terminal as the Remote Unit. Use bonding
cables of the same length, as short as possible and with a large wire cross
section. Follow local electrical code practices.
4.2.5. Connection of the Antenna Cables
The Remote Unit has N-type antenna connector. Please refer to section 4.2.3 for its
location. Refer to the corresponding documentation of the connector manufacturer for
mounting the cable connectors.
The bending radius of the antenna cables must remain within the given
specifications.
Choose the type of cable best suited for the antenna. Consider that a cable with
higher loss is less expensive but impairs performance.
Notice: Use an appropriate torque wrench for the coupling torques:
- for N-type connectors (2 N-m / 20 in lb) with 13/16 in opening,
e. g. item no. 244379 available from the CommScope e-catalog
- for 7/16 DIN-type (25 N-m / 19 ft lb) with 1 ¼ in opening,
e. g. item no. 244377 available from the CommScope e-catalog
Do NOT use your hands or any other tool (e.g. a pair of pliers)! This might
cause damage to the connector and lead to a malfunction of the RU.
figure 4-7 Torque wrench for tightening
Attention: To minimize passive inter-modulation (PIM) distortion, attention has to be
paid to the physical condition of the connector junctions:
Do not use connectors that show signs of corrosion on the metal surface.
Prevent the ingress of water or dirt into the connector.
Use protective caps for the connectors when not mounted.
Before mounting clean the connectors with dry compressed air.
Before mounting clean the mating surfaces of the connector with a lint-free
alcohol-drenched cloth on a wooden or non-metallic item.
Attach and torque the connectors properly.
Avoid metallic abrasion when mounting the connectors by only screwing the
connecting nut, but not turning the whole connector.
Use a torque wrench to fasten the connector, see above.
Clean the protective caps before mounting for antenna cable replacement.
Page 22 MF0150A3A.doc Manual for ION-M7P/17EHP
4. Commissioning
4.2.6. Cleaning Procedure for RF Cable Connectors
The figures in this chapter illustrate the cleaning procedure and do not show the
actual RU.
1. What is needed for the cleaning?
a. Isopropyl alcohol
b. Compressed air
c. Lint-free wipe
d. Cotton buds
2. Remove protective cap from the RF
connector.
Caution: Risk of injury by flying particles when compressed air is used. Wear
protective clothing, especially protective glasses.
3. Remove metal chips and small
particles from the mating and inner
surfaces of the connector using
compressed air.
MF0150A3A.doc Manual for ION-M7P/17EHP Page 23
4. Commissioning
Warning: Flammable material. Risk of fire. Keep away from sources of ignition.
Caution: Eye irritant product. Risk of eye irritation. Avoid contact with eyes and skin.
Wear protective clothing, especially protective glasses.
4. Clean the connector winding with lintfree wipe drenched with isopropyl
alcohol.
5. Clean the lip of the inner ring with a
cotton bud drenched with isopropyl
alcohol.
6. Clean the inside surface of the inner
ring with a cotton bud drenched with
isopropyl alcohol.
7. Clean the inside of the center
conductor spring tines with a cotton
bud drenched with isopropyl alcohol.
Page 24 MF0150A3A.doc Manual for ION-M7P/17EHP
4. Commissioning
8. Clean in the similar way the
connector of the connected cable.
Remove protective caps from the unit
connector first.
9. Remove metal chips and small
particles from the mating and inner
surfaces of the connector using
compressed air.
10. Continue with the winding area using
lint-free wipe drenched with isopropyl
alcohol.
11. Continue with the inside mating
surface of the inner ring.
12. Clean the outside surface of the
center pin.
MF0150A3A.doc Manual for ION-M7P/17EHP Page 25
4. Commissioning
4.2.7. Antenna Cable Connector Assembly
The figures in this chapter illustrate the connection procedure and do not show the
actual RU.
1. What is needed for the connector
assembly?
a. Torque wrench.
b. (Adjustable) counter wrench
2. Join the connectors and turn the
coupling nut until the thread grips.
3. Push in the connector until it clicks.
4. Fasten the coupling nut hand-tight. Do
not turn the connector but the coupling
nut only.
Page 26 MF0150A3A.doc Manual for ION-M7P/17EHP
4. Commissioning
5. Retain the cable connector with the
counter wrench and fasten the
Torque wrench
coupling nut with the torque wrench
until the torque is applied (torque
wrench clicks).
For angled antenna connectors use your
hand to retain the cable connector and
fasten the coupling nut with the torque
wrench. Make sure only the coupling nut
Counter
wrench
is turned, not the cable connector.
4.2.8. Optical-Fiber-Cable Connection - Rules
Main optica l system parame ters:
Fiber:
Single mode fiber, type is E9/125 µm
Attenuation: <0.36 dB / km @ 1310 nm / <0.26 dB / km @ 1550 nm
Dispersion: <3.5 ps / nm km @ 1310 nm / <18.0 ps / nm km @ 1550 nm
Fibre-cable connectors E2000 APC 8°
ION-M system:
The pigtails for the connection between Master Unit and Remote Unit must
have a sufficient length. Protection for the optical fibers must be provided
where the fibers feed into the units.
The system attenuation of the optical fibers, including the connectors, must
not exceed 10 dB.
System attenuation and attenuation of optical components must be determined. This
can be achieved by measuring attenuation and reflection with an appropriate
measuring instrument. For pigtails, a total value of <0.4 dB (measured to a reference
plug) can be assumed due to the dead zone of the reflectometer. These
measurements must be made with a sufficient length of optical fiber, at the input and
output of the device which has to be measured.
MF0150A3A.doc Manual for ION-M7P/17EHP Page 27
Fiber-System Installation:
Fiber-cable connectors have to be of the same type (E2000 APC 8°) as the
connectors used for the unit. The fiber-optic cables are connected to the optical
transceiver.
4. Commissioning
Note: Angled connectors are not compatible with straight optical
connectors; non-compatibility of connectors will result in
permanent damage to both connectors.
Before connecting the fiber cables, follow the procedure below to ensure optimized
performance. It is important for these procedures to be carried out with care:
Remove fiber-optic protective caps.
Do not bend the fiber-optic cable in a tight radius (<4 cm) as this may cause
cable damage and interrupt transmission.
Using high-grade alcohol and lint-free cotton cleaning swabs, clean the end of
the fiber-optic cable that will be inserted in the optical connectors on the donor
interface box. Use a fiber end-face inspection tool to scan both, the class fiber
and its surrounding area.
Check for dirt on the cladding, chips/pits, dirt on the ferrule, and scratches.
Connect the fiber-optic cables by inserting the cable end into the laser
receptacle and aligning the key (on the cable end) with the keyed slot.
Do not use any index-matching gels or fluids of any kind in these connectors.
Gels are intended for laboratory use and attract dirt in the field.
Note: Care should be taken when connecting and disconnecting fiber-
optic cables - use the connector housing to plug or unplug a fiber.
Scratches and dust significantly affect system performance and
may permanently damage the connector. Always use protective
caps on fiber-optic connectors not in use.
Cleaning Procedure for Fiber-Optical Components:
Caution: Laser radiation. Risk of eye injury in operation. Do not stare into the
beam; do not view it directly or with optical instruments.
Any impurity in the fiber connection results in additional optical transmission loss
which could cause whole system failure. It is thus recommended that every fiber
connector be inspected and cleaned prior to mating.
When you clean fiber components, always complete the following steps carefully:
1. Turn off the ION system (laser sources) before you inspect fiber connectors.
2. Check the connectors or adapters with a fiberscope before cleaning.
Page 28 MF0150A3A.doc Manual for ION-M7P/17EHP
4. Commissioning
3. If the connector is dirty, clean it with a lint-free wipe (dry cleaning).
4. Inspect the connector.
5. If the connector is still dirty, repeat the dry cleaning technique.
6. Inspect the connector.
7. If the connector is still dirty, clean it with 99% isopropyl alcohol (wet cleaning)
followed immediately with a dry clean in order to ensure no residue is left on
the end face.
8. Repeat steps 5 through 7 until end face is clean.
Note: For a more detailed description, please refer to:
A protective plug is provided for the connection of the fibre-optic cables.
Note: Only high-quality connectors must be used for this type of plug.
Qualified brands are Diamond or Huber & Suhner.
MF0150A3A.doc Manual for ION-M7P/17EHP Page 29
figure 4-8 Protective-plug assembly
4. Commissioning
For plug assembly, observe the following instruction:
1. Pass one or two contacts through the
backshell and the clamp ring.
2. Place the contact(s) on the lower insulation body by pushing the groove of the
contact into the cavity. If there is only one contact, cavity A must be used. *
3. Then, mount the upper insulation body on the lower insulation body. **
Upper insulation body
Cavity A
Cavity B
4. Bring the insulator into the plug. The narrow groove of the insulator must be fitted
into the stamp of the plug.
* To release the contact for disassembling, push the inner snap to the side and pull the contact out.
** To release upper and lower insulation bodies for disassembling, use a small screwdriver and
carefully open the snap-connections at the left and the right side of the insulator without
damaging them.
5. Fasten the insulator by screwing the
backshell tight onto it. Use a spanner
with opening 32 to screw the
backshell tight (no gap).
6. Place the appropriate seal parts (with
one groove for one contact or two
grooves for two contacts) over the
cable(s) and push them into the
backshell.
No gap
Seals with
one groove
Page 30 MF0150A3A.doc Manual for ION-M7P/17EHP
4. Commissioning
back to
ectio
7. Bring the plastic ring over the cable(s), push it into the backshell and compress
the seals and plastic ring by screwing the clamp ring tight (no gap) using a
spanner with opening 20. ***
Screw tight until gap is closed
8. Connect the plug to the optical-fibre
connector of the Remote Unit, again
9. To lock the connector, push the black
locking ring forward.****
by fitting a stamp on the plug into the
groove of the connector.
Groove
*** For disassembling, release the clamping ring and remove the seals and the plastic ring first.
**** Locking mechanism: The system of locking the plug is based on a “push-pull” mechanism. The
locking ring has to be pushed forward to lock the connector and pulled back to free the
connection.
Push forward to lock, pull
free conn
n
4.2.10. Protective-Tube Kit
As additional protection for the optical fibres, this connector type can be
supplemented by a special tube kit. To fasten the tube correctly, first unscrew the
clamp ring (if already installed) of the original plug kit.
Then, proceed according to the following instruction:
MF0150A3A.doc Manual for ION-M7P/17EHP Page 31
Place the appropriate seal
parts (with) one groove for
one contact or two grooves
for two contacts) over the
cable(s) and push them into
the backshell!
Protective plug
Fiber cable
Ring 3/4
Reducer
4. Commissioning
Screw the reducer to
the protective plug
backshell without any
gap!
Coupling
Protective tube
Push the fiber-optic cable carefully
through the tube until it comes out
at the other end.
Page 32 MF0150A3A.doc Manual for ION-M7P/17EHP
figure 4-9 Tube-kit installation
G1055M0
4. Commissioning
4.2.11. External-Alarm Inputs and Outputs
There are four alarm inputs and four alarm outputs. Each alarm output can be
assigned individually to any alarm at the Remote Unit. Settings need to be made via
the ION-M Master Controller. For details please refer to the corresponding chapter in
the User’s Manual of the ION-M Master Controller.
Note: The manufacturer / supplier of this system assumes no liability for
damage caused by equipment connected to external outputs or by
effects from such equipment.
As accessory equipment the alarm kit is available to connect external devices to the
external alarm inputs and outputs. For the exact ID No., please refer to section 7.3
Spare Parts. Subminiature circular connectors series 712 with five and seven
contacts, which are contained in the alarm kit, can be ordered directly from the
Binder Connector Group, the manufacturer, or indirectly from CommScope.
For the location of the external-alarm inputs and outputs see figure “Connector
Flange”.
Optocoupler-Alarm Inputs
With the external alarm inputs it is possible to monitor the status of connected
devices, e.g. a UPS, via software. All alarm inputs are normally high (5 V) without
connection. The polarity (high/ low) can be set via the software at the Master Unit (for
details please see corresponding software manual).
The alarm outputs (pins 1 to 4: open collector output 5 V / 1 mA; see figure 4-13) are
normally low. In case of an alarm they are high active (5 V). They can be used to
monitor alarms with an external alarm indicator.
Note: The manufacturer / supplier of this system assumes no liability for
damage caused by equipment connected to external outputs or by
effects from such equipment.
Page 34 MF0150A3A.doc Manual for ION-M7P/17EHP
4. Commissioning
4.2.12. Power Connection
Before connecting electrical power to the RU, the system must be grounded as
described in section 4.2.4 Grounding (Earthing).
Mains power must be connected at the mains connector of the unit (see section
4.2.3). The power supply plug with cable is part of the delivery. Depending on the
location / requirements of your site, one of the following cables is provided:
blue neutral
brown phase
yellow/green protection earth
white neutral
black phase
green protection earth
figure 4-14 Power supply cables (AC)
figure 4-15 Power supply cable (DC)
red + (volts)
black - (volts)
Connect the cable ends of the power cable to your local power supply.
Note: Observe the applicable national regulations regarding loop impedance,
voltage drop, and methods of installation. Make sure to connect the
correct voltage to the unit.
Note: Do not connect or disconnect the power cord at the mains connector while
power is on. Turn off mains power * before connecting the power cord at
the Remote Unit, then, engage mains again.
* Mains power must be interruptible with an external delay-actions mains breaker. For the mains
breaker, observe the following recommendation:
120 Volt / 20 Amp max. or 240 Volt / 16 Amp, single-phase, 50 / 60 Hz AC service is needed,
i.e. the external AC breaker should be 20 Amps max. for 120-Volt service or 13 to 16 Amps for
240-Volt service. Always make sure that your local requirements are kept.
For the DC power supply, observe the local regulations of the DC service provider.
With the mains power turned off, the power supply plug must be connected to the
Remote Unit’s mains connector.
MF0150A3A.doc Manual for ION-M7P/17EHP Page 35
4.2.13. Commisioning Flowchart
Commissioning an ION-M Remote Unit
4. Commissioning
Manual for Remote
Unit
Philips
screwdriver
Mounting kit
Spanner, size
13 mm
Drilling
machine
Dowels
Screw driver
Screw driver
Spanner, size
13 mm
Grounding cable
Spanner 13 mm
Alarm kit
(M-cabinet)
Start
Preperation
Unpack RU, RU accessories and
mounting kit.
Mechanical installation
Fasten wall or pole mounting kit to wall or
Mount RU to mounting kit, ensure suffient
air flow and avoid thermal short circuits.
Connect grounding cable and
Connect external devices to the external
in or alarm out connectors, or to the
connecting board inside the RU.
pole.
Mechanical installation
Electrical connections
ground the RU.
External devices
RF connection
Optical connections
connector into the RU.
Electrical connections
mains and RU.
Mains
Switch mains power on.
G1055Z0
E2000 APC8° connector
Spanner with opening 32
Mains cable
Connecting kit
Connect antenna cable to antenna port.
Mount the optical fibre with E2000 APC8°
connector into the connector . Plug the
Connect AC power to the power cable.
Ensure there is a circuit breaker between
Page 36 MF0150A3A.doc Manual for ION-M7P/17EHP
4. Commissioning
Orange
LED on?
Yes
LED status
Green
No
Check power switch inside RU
(RUs with door).
Check mains cabling.
Check mains power.
Red
.
LED statusYellow
Internal Error
Red
Change power supply (RUs with a
door)
Reduce environmental temperature.
Eliminate thermal short circuit.
Disconnect and connect mains. Fans
should run. If not, replace the fans at
RU.
MU: Change amplifier setting at MU
controller
Yes
Go to MU
Close the door (RUs with a door).
Check externally connected devices.
Check fibre loss of optical link.
Check optical connectors.
Clean optical connectors.
Check optical output power of corresponding
OTRx at master unit.
ALC alarm: Decrease DL input power of
affected band.
VSWR alarm: Check antenna and cable.
External error
Proceed to MU to set up the SW
Finished setting up
all RUs?
Yes
Output:
All RUs okay.
Green
Spare RU
available?
No
Contact customer
service
No
MF0150A3A.doc Manual for ION-M7P/17EHP Page 37
5. Alarms and Troubleshooting
5. Alarms and Troubleshooting
All alarms occurring can be checked via software at the Master Unit to where a
message is transmitted when the software acknowledges a valid alarm. A new alarm
message will not be repeated if the reason for the alarm is cleared or if the alarm
continues.
A new alarm message will be generated if the alarm is interrupted for at least five
seconds after acknowledgement. Refer to the corresponding software documentation
of the Master Unit for details.
For local supervision, a status LED on the connector flange of the unit (position see
section 4.2.3) gives an indication of possible reasons for alarms. This table shows
possible on-site measures that could be checked before referring to the Master Unit
alarm list.
LED Alarms Possible on-site measures
Green No alarm Status ok
Alarms not directly related to RU/EU:
Check externally connected devices.
Check fibre loss of optical link.
(MU: Check optical output power of
corresponding OTRx at Master Unit).
(MU: Decrease DL input power of affected
band).
Change power supply (RUs with door).
Replace the affected Remote Unit.
Reduce environmental temperature.
Eliminate thermal short circuit.
Disconnect and connect mains. Fans should
run. If not, replace the fans at RU.
(MU: Change amplifier setting at MU
controller).
Check power switch inside of RU/EU
(RUs/EUs with door).
Check mains cabling.
Check mains power.
Orange
Red
Status
LED off
External alarms (RU only)
Optical alarm Rx
(RU only)
ALC alarm
Alarms directly related to RU/EU:
Power 32 V
Temperature
Fan (RUs/EUs with fan)
I²C Disconnect and connect mains.
Optical alarm Tx Exchange RU/EU.
Amplifier “Power Down”
Mains
The status of the RU/EU can be checked via the Master Unit (for details please refer
to the software manual of the Master Controller).Explicit troubleshooting is also
available in the MU software (software manual or WEB Interface).
The connection of the external alarms inputs and outputs provided is described in
chapter 4.2.11.
Page 38 MF0150A3A.doc Manual for ION-M7P/17EHP
table 5-1 Status LED alarms
6. Maintenance
6. Maintenance
6.1. General
Read and observe chapter 1.2 Health and Safety.
Caution: Rotating fans. Risk of injury in operation. Wear tight-fitting clothes and
disconnect mains before connecting or replacing or cleaning the fan unit.
Caution: The unit reaches high temperature in operation. Risk of burns by hot
surface. Do not touch the unit before it has sufficiently cooled down.
Note: The Remote Unit does not require preventative maintenance measures.
Note: We recommend checking the cleanliness of the unit and in particular of
the heat sink / fan(s) at appropriate intervals depending on the degree of
dust and dirt at the installation site. If necessary, any dusty or dirty areas /
parts should be cleaned at regular intervals, which also depend on the
degree of dust and dirt at the installation site.
Maintenance of the RU should be performed by replacing only components that are
contained in this section. Take care not to unintentionally damage the seals on the
modules to maintain warranty. Please keep these guidelines in mind during
maintenance:
Unless otherwise agreed to in writing by CommScope, CommScope’s general limited
product warranty (http://www.commscope.com/Resources/Warranties/) shall be the
warranty governing the Remote Units, including the installation, maintenance, usage
and operation of the Remote Units.
The spare parts list, consequently, contains only units which can be replaced without
tuning or soldering work.
Note: Ensure the Remote Unit has been disconnected from mains power
during maintenance.
Note: When sending back the unit, use appropriate packaging. Use of the
original packaging for shipping the unit is strongly recommended.
Note: Defective parts should only be replaced by original parts from the
supplier. All service work performed inside the housing is performed at
the users own risk.
Note: Label any unlabelled cables before disconnecting them to ensure
correct reconnection.
For most maintenance procedures, appropriate tools are required to ensure correct
handling. All of these tools can be ordered from the supplier.
Note: All Remote Unit screws have a right-hand thread, and are tightened by
turning the screws clockwise and loosened by turning them counterclockwise with an appropriate tool.
Due to the design of the Remote Unit the only component recommended to be
replaced is the fan unit. For replacing any other component, please contact the
supplier.
MF0150A3A.doc Manual for ION-M7P/17EHP Page 39
6. Maintenance
6.2. Replacing the Fan Unit
Replacement of the fan unit is not required as a preventative measure. Only if an
alarm indicates a malfunctioning of a fan must the unit be exchanged.
Note: Please observe that the fan unit can only be replaced as a whole. Do
not remove the fans separately.
Read and observe chapter 1.2 Health and Safety as well as the instructions in
section 6.1 General before starting with the replacement.
1. Switch off the Remote Unit. Make sure mains is disconnected for the following replacement procedure. Then, proceed as follows:
2. Loosen the four tallow-drop screws
M4x8 by which the fan plate is
screwed to the cabinet. Remove the
four screws and the corresponding
washers.
3. Remove the fan unit – by putting slight
pressure on the fan plate cover – to a
position that allows access to the fan
connector and the earth-bonding
cable.
4. Unscrew the fan connector and then
disconnect the earth-bonding cable.
Fan-unit connector
Earth-bonding cable
5. To mount the new fan unit, reconnect the earth-bonding
cable and the fan connector
(see step 4). Then, place the
fan unit back into its original
position and fasten it tight:
6. Screw the whole fan unit to the cabinet with the four tallow-drop screws M4x8
(see step 2). In order not to exceed the specified torque of 3.3 N-m, use an
appropriate tool.
Page 40 MF0150A3A.doc Manual for ION-M7P/17EHP
6. Maintenance
(5 ba
)
6.3. Cleaning the Heat Sink
Note: Read and observe chapter 1.2 Health and Safety as well as the
instructions in section 6.1 General before starting with the replacement
procedure. Then, proceed as follows:
1. Switch off the Remote Unit. For the following procedure ensure that mains has
been disconnected before.
2. Remove the fan plate with the fan unit
from the Remote Unit as described in
section 6.2 Replacing the Fan Unit,
steps 1 and 2:
Brush (not metallic)
Caution: Risk of injury by flying particles when compressed air is used. Wear
protective clothing, especially protective glasses.
Compressed air
r max.
3. Use compressed air (max. 5 bar) to
blow out the heat sink from back to
front.
4. In case the dirt cannot be blown out completely and parts of it stick to the ribs of
the heat sink, clean the parts concerned carefully from the front using e.g. a
brush. Take care that the material is not scratched or damaged.
5. After cleaning the heat sink, mount the fan unit again according to section 6.2 Replacing the Fan Unit step 6. Then, switch the Remote Unit back on.
MF0150A3A.doc Manual for ION-M7P/17EHP Page 41
7. Appendix
7.1. Illustrations
7. Appendix
Page 42 MF0150A3A.doc Manual for ION-M7P/17EHP
figure 7-1 Cabinet drawing
7. Appendix
7.2. Specifications
7.2.1. SW Requirements
Minimum SW requirements for basic support: ION-M SW V7.0.1
7.2.2. Electrical Specifications
Electrical
Power
supply
Optical link connectors E2000/APC 8°
Optical return loss 45 dB min.
Fibre type Single mode E9/125 µm
Optical link budget 0 dB to 10 dB
Mains power
Power consumption
nominal 100 Vac to 240 Vac
operating 85 Vac or 264 Vac
Height, width, depth * 831 x 156 x 147 mm (32.7 x 6.1 x 5.8 in)
Weight, 22 kg (48 Ib)
* Spacing required 40 mm (1.58 in) around unit
All data is subject to change without notice.
7.2.4. Environmental and Safety Specifications
Note: For detailed information, please refer to the Environmental and Safety
Specifications leaflet of the supplier, related to ETS 300 019 (European
Telecommunication Standard).
Operating temperature range -33° C to +50° C
Ingress protection
All data is subject to change without notice.
RF part IP67
Fan part IP55
MF0150A3A.doc Manual for ION-M7P/17EHP Page 43
7. Appendix
7.3. Spare Parts
The following list contains all parts available for the Remote Unit. The configuration of
the delivered unit meets the requirements of the customer and can differ depending
on the state of the delivery.
Maintenance of the RU should be performed on an FRU (Field Replaceable Unit)
basis only. Do not damage the warranty labels on the components, as this voids the
warranty.
If any FRU not contained in the following list needs to be replaced, please contact
customer service for additional instructions.
Designation: ID No:
ION-M7P/17EHP
Protective Plug E2000 7160013
Protective Cap E 2000 7158914
Fan Protection Kit 7159097
Fan Unit 7158254
Protective Tube Kit 7162182
Manuals for ION-M7P/17EHP 7714243-00
Accessories
Wall Mounting
Wall-Mounting Kit 7158078
ISO Trafo Kit 230 V Wall Mounting 7158322
Overcoat Housing Kit Wall Mounting 7159625
Pole Mounting
Pole-Mounting Kit 7157782
ISO Trafo Kit 230 V Pole Mounting 7159621
Overcoat Housing Kit Pole Mounting 7159624
Alarm Kit 7157396