CommScope ION-M7P, ION-M19P, ION-M17P, ION-M85P, ION-7P User Manual

...
Optical Remote Unit
ION™-M7P/85P/17P/19P
(ML-Cabinet)
MF0143AUA
© Copyright 2011 CommScope, Inc. All rights reserved.
User’s Manual for
ION™-M7P/85P/17P/19P (ML-cab)
Andrew Solutions is a trademark of CommScope, Inc. All information contained in this manual has been revised thoroughly. Yet Andrew
Solutions accepts no liability for any omissions or faults. Andrew Solutions reserves the right to change all hard- and software characteristics
without notice. Names of products mentioned herein are used for identification purposes only and
may be trademarks and / or registered trademarks of their respective companies. No parts of this publication may be reproduced, stored in a retrieval system,
transmitted in any form or by any means, electronical, mechanical photocopying, recording or otherwise, without prior written permission of the publisher.
Andrew Wireless Systems GmbH, 24-November-2011
Page 2 MF0143AUA.doc
TABLE OF CONTENTS
1. GENERAL 7
1.1. USED ABBREVIATIONS 7
1.2. HEALTH AND SAFETY WARNINGS 8
1.3. ABOUT ANDREW SOLUTIONS 10
1.4. INTERNATIONAL CONTACT ADDRESSES FOR CUSTOMER SUPPORT 12
2. INTRODUCTION 15
2.1. PURPOSE 15
2.2. THE ION™-M7P/85P/17P/19P (INTELLIGENT OPTICAL NETWORK; MMR) 15
3. COMMISSIONING 17
3.1. MECHANICAL INSTALLATION 17
3.1.1. General 17
3.1.2. Wall-Mounting Procedure 19
3.1.3. Pole-Mounting Procedure 20
3.2. ELECTRICAL INSTALLATION 21
3.2.1. General 21
3.2.2. Connections 23
3.2.3. Grounding 24
3.3. CONNECTION OF THE ANTENNA CABLES 24
3.4. POWER CONNECTION 25
3.5. OPTICAL-FIBER-CABLE CONNECTION - RULES 26
3.5.1. Protective Plug 29
3.5.2. Protective-Tube Kit 31
3.6. COMMISSIONING 33
4. ALARMS 37
4.1. BITE AND ALARMS 37
4.2. HANDLING OF ALARMS 37
4.3. ALARM STATUS 37
4.4. STATUS LED ALARMS 37
4.5. EXTERNAL ALARM INPUTS AND OUTPUTS 39
Page 3
User’s Manual for
ION™-M7P/85P/17P/19P (ML-cab)
4.6. TROUBLESHOOTING 40
5. MAINTENANCE 41
5.1. GENERAL 41
5.2. REPLACING THE FAN UNIT 42
5.3. CLEANING THE HEAT SINK 43
6. APPENDIX 45
6.1. ILLUSTRATIONS 45
6.2. SPECIFICATIONS 46
6.2.1. Electrical Specifications 46
6.2.2. Mechanical Specifications 46
6.2.3. Environmental and Safety Specifications 46
6.3. SPARE PARTS 47
7. INDEX 49
Page 4 MF0143AUA.doc
FIGURES AND TABLES
figure 3-1 Mounting bracket installation.................................................................... 19
figure 3-2 RU mounting ............................................................................................ 19
figure 3-3 Pole-mounting kit...................................................................................... 20
figure 3-4 Connector flange of ION-M7P/85P/17P/19P............................................ 23
figure 3-5 RS485 connector...................................................................................... 23
figure 3-6 Grounding bolt.......................................................................................... 24
figure 3-7 Grounding bolt, schematic view................................................................ 24
figure 3-8 AC power supply plug............................................................................... 25
figure 3-9 Protective-plug assembly ......................................................................... 29
figure 3-10 Tube-kit installation................................................................................. 32
figure 4-1 Flange connector, 5 poles........................................................................ 39
figure 4-2 Flange connector, 7 poles........................................................................ 39
figure 4-3 Alarm inputs and outputs, standard.......................................................... 40
figure 5-1 Fan unit and heat sink.............................................................................. 42
figure 6-1 Cabinet drawing........................................................................................ 45
table 1-1 List of international contact addresses....................................................... 13
table 3-1 Specified torques....................................................................................... 18
table 3-2 RS485 connector, pin assignment............................................................. 23
table 4-1 Status LED alarms..................................................................................... 38
Page 5
For your notes:
User’s Manual for
ION™-M7P/85P/17P/19P (ML-cab)
Page 6 MF0143AUA.doc
1 General
1. GENERAL

1.1. USED ABBREVIATIONS

3GPP 3rd Generation Partnership Project AC/DC Alternating current / Direct Current AIMOS Andrew Integrated Management and Operating System ALC Automatic Level Control BITE Built-In Test Equipment BTS Base Transceiver Station CE "Conformité Européenne" ("European Conformity") CD Compact Disk CPD Channel Power Detection DL Downlink DoC Declaration of Conformity EDGE Enhanced Data Rates for GSM Evolution EN European Norm EP Extension Port ESD Electrostatic Discharge ETS European Telecommunication Standard EU Extension Unit GSM Global System for Mobile Communication GND Ground GUI Graphical User Interface ICP3 Intercept Point 3 ID No Identification Number ION Intelligent Optical Network IP Ingress Protection ISO International Organization for Standardization LED Light Emitting Diode LMT Local Maintenance Terminal LTE Long Term Evolution MIMO Multiple Input Multiple Output MS Mobile Station MU Main Unit NF Noise Figure OTRx Optical Transceiver = SRMU (Subrack Master Unit) PDU Power Distribution Unit PG Packing Gland PIM Passive Intermodulation R&TTE Radio & Telecommunications Terminal Equipment Rev Revision RF Radio Frequency RU Remote Unit RX Receiver SNMP Simple Network Management Protocol TS Technical Specification TX Transmitter UL Uplink UMTS Universal Mobile Telecommunication System UPS Uninterruptible Power Supply VSWR Voltage Standing Wave Ratio WCDMA Wideband Code Division Multiple Access WDM Wavelength Division Multiplex
rd
order
Page 7
User’s Manual for

1.2. HEALTH AND SAFETY WARNINGS

1. Only suitably qualified personnel is allowed to work on this unit and only after becoming familiar with all safety notices, installation, operation and maintenance procedures contained in this manual.
2. Read and obey all the warning labels attached to the unit. Make sure that the warning labels are kept in a legible condition and replace any missing or damaged labels.
3. Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment.
4. Keep operating instructions within easy reach and make them available to all users.
5. It is the responsibility of the network provider to implement prevention measures to avoid health hazards which may be associated to radiation from the antenna(s) connected to the unit.
ION™-M7P/85P/17P/19P (ML-Cab)
6. For US and Canadian installations: To comply with FCC RF exposure compliance requirements, the following antenna installation and device operating configurations must be satisfied: A separation distance of at least 4 m must be maintained between the antenna of this device and all persons. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of
1.1307(b)(3). Maximum permissible antenna gain is 17 dBi.
7. Please note for a Class A digital device or peripheral:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
8. Make sure, access is restricted to qualified personnel.
9. Only licence holders for the respective frequency range are allowed to operate this unit.
10. Corresponding local particularities and regulations must be observed. For national deviations please refer to the respective documents included in the manual CD delivered.
Page 8 MF0143AUA.doc
1 General
11. Use this equipment only for the purpose specified by the manufacturer. Do not carry out any modifications or fit any spare parts which are not sold or recommended by the manufacturer. This could cause fires, electric shock or other injuries.
12. Due to power dissipation, the repeater may reach a very high temperature. Do not operate this equipment on or close to flammable materials.
13. Before opening the unit, disconnect power supply.
14. ESD precautions must be observed! Before commencing maintenance work, use the available grounding system to connect ESD protection measures.
15. This unit complies with European standard EN60950.
16. Make sure the repeater settings are according to the intended use (see also product information of manufacturer) and regulatory requirements are met.
17. Although the repeater is internally protected against overvoltage, it is strongly recommended to earth the antenna cables close to the repeater’s antenna connectors for protection against atmospheric discharge.
18. Laser radiation! Do not stare into the beam; do not view it directly or with optical instruments.
Page 9
User’s Manual for

1.3. ABOUT ANDREW SOLUTIONS

Andrew Wireless Systems GmbH based in Buchdorf/ Germany, is a leading manufacturer of coverage equipment for mobile radio networks, specializing in high performance, RF and optical repeaters. Our optical distributed networks and RF repeater systems provide coverage for every application: outdoor use, indoor installations, tunnels, subways and many more.
Andrew Wireless Systems GmbH has unparalleled experience in providing RF coverage and capacity solution for wireless networks in both indoor and outdoor environment and belongs to Andrew Solutions, a CommScope Company.
Andrew Solutions is the foremost supplier of one-stop, end-to-end radio frequency (RF) solutions. Our products are complete solutions for wireless infrastructure from top-of-the-tower base station antennas to cable systems and cabinets, RF site solutions, signal distribution, and network optimization.
Andrew Solutions has global engineering and manufacturing facilities. In addition, it maintains field engineering offices throughout the world.
We operate a quality management system in compliance with the requirements of ISO 9001. All equipment is manufactured using highly reliable material. In order to ensure constant first-rate quality of the products, comprehensive quality monitoring is conducted at all fabrication stages. Finished products leave the factory only after a thorough final acceptance test, accompanied by a test certificate guaranteeing optimal operation.
) Note: Exceptions of and national deviations from this intended use may be
possible. To observe corresponding local particularities and regulations, please refer to the respective documents (also in national language) which are included in the manual CD delivered.
To make the most of this product, we recommend you carefully read the instructions in this manual and commission the system only according to these instructions.
For technical assistance and support, please also contact the local office or Andrew Solutions directly at one of the addresses listed in the following chapter.
ION™-M7P/85P/17P/19P (ML-Cab)
Page 10 MF0143AUA.doc
1 General
Page 11
User’s Manual for
ION™-M7P/85P/17P/19P (ML-Cab)

1.4. INTERNATIONAL CONTACT ADDRESSES FOR CUSTOMER SUPPORT

Americas:
Canada United States
Andrew Solutions Canada
620 North Greenfield Parkway
Mail
Phone Fax +1-905-878-3297 Fax +1-919-329-8950
E-mail
Mail
Phone + 55-15-9104-7722 Phone Fax + 55-15-2102-4001 Fax +52-55-1346-1901
E-mail WIsupport@commscope.com
Garner, NC 27529 U.S.A.
+1-905-878-3457 (Office) +1-416-721-5058 (Mobile)
Peter.Masih@commscope.com, WIsupport.us@commscope.com
Brazil & South America
CommScope Cabos do Brasil Ltda.
Av. Com. Camilo Julio 1256 Zonal Industrial CP 597 Sorocaba SP 18086-000 Brazil
Andrew LLC, A CommScope Company
Mail
Phone +1-888-297-6433
E-mail WIsupport.us@commscope.com
Mail
E-mail WIsupport@commscope.com
Andrew Solutions,
620 North Greenfield Parkway Garner, NC 27529 U.S.A.
Mexico, Central America &
Caribbean region
Andrew Corporation Mexico,
SA DE CV
Av. Insurgentes Sur 688, Piso 6 Col. Del Valle, CP: 03100 Mexico City Mexico
+52-55-1346-1900 (Office) +52-1-55-5419-5260 (Mobile)
APAC Countries:
China, India and Rest of Asia Australia & New Zealand
Andrew International Corporation Andrew Corporation (Australia) Pty Ltd.
Room 915, 9/F Chevalier Commercial Centre
Mail
Phone +852-3106-6100 Phone +613-9300-7969 Fax +852-2751-7800 Fax +613-9357-9110
E-mail WIsupport.China@commscope.com
8 Wang Hoi Rd Kowloon Bay Hong Kong
Mail
E-mail WIsupport.Australia@commscope.com
Unit 1 153 Barry Road Campbellfield VIC 3061 Australia
Page 12 MF0143AUA.doc
1 General
Europe:
United Kingdom France
Andrew Solutions UK Ltd CommScope France
Unit 15, Ilex Building Mulberry Business Park
Mail
Phone +44-1189-366-792 Phone Fax +44-1189-366-773 Fax E-mail WIsupport.uk@commscope.com
Mail
Phone +49-9099-69-0 Phone +420-464-6280-80 Fax +49-9099-69-930 Fax +420-464-6280-94
Fishponds Road Wokingham Berkshire RG41 2GY England
Germany Czech Republic
Andrew Wireless Systems GmbH
Industriering 10 86675 Buchdorf Germany
Mail
E-mail WIsupport@commscope.com
Mail
Immeuble Le Lavoisier 4, Place des Vosges 92052 Courbevoie France
+33-1 82 97 04 00 +33-1 47 89 45 25
Andrew Solutions Czech Republic
C-Com, spol. s r.o
U Moruší 888 53006 Pardubice Czech Republic
E-mail WIsupport@commscope.com
Austria Switzerland
Andrew Wireless Systems (Austria) GmbH Andrew Wireless Systems AG
Weglgasse 10
Mail
Phone +43-1706-39-99-10 Phone +41-62-386-1260 Fax +43-1706-39-99-9 Fax +41-62-386-1261
E-mail WIsupport.austria@commscope.com
Mail
Phone +39-0546-697111 Phone +34-91-745-20 40 Fax +39-0546-682768 Fax +34-91-661-87 02 E-mail WIsupport.italia@commscope.com
2320 Wien-Schwechat Austria
Italy Spain and Portugal
Commscope Italy S.r.l., Faenza, Italy
Via Mengolina, 20 48018 Faenza (RA) Italy
E-mail WIsupport@commscope.com
Tiergartenweg 1
Mail
E-mail WIsupport.ch@commscope.com
Mail
E-mail WIsupport.iberia@commscope.com
CH-4710 Balsthal Switzerland
Andrew Solutions España S.A.
A Commscope Company
Avda. de Europa, 4 - 2ª pta. Parque Empresarial La Moraleja 28108 Alcobendas (Madrid) Spain
table 1-1 List of international contact addresses
Page 13
For your notes:
User’s Manual for
ION™-M7P/85P/17P/19P (ML-Cab)
Page 14 MF0143AUA.doc
2 Introduction
2. INTRODUCTION

2.1. PURPOSE

Cellular telephone systems transmit signals in two directions between a base transceiver station (BTS) and mobile stations (MS) within the signal coverage area.
If weak signal transmissions occur within the coverage area because of indoor applications, topological conditions or distance from the transmitter, extension of the transmission range can be achieved by means of an optical distribution system.
Such a system contains an optical Master Unit and several Remote Units. The number of the Remote Units depends on the hardware and software configuration. The Remote Units are connected to the Master Unit with optical links. The optical loss must be less than 10 dB inclusive optical couplers or splitters.
The Master Unit is the connection to the base transceiver stations. The configuration of a Master Unit depends on the number of the Remote Units and the frequency range.
The optical transmission uses WDM-systems with a wavelength of 1550 nm in the uplink and 1310 nm in the downlink.

2.2. THE ION™-M7P/85P/17P/19P (INTELLIGENT OPTICAL NETWORK; MMR)

The ION-M7P/85P/17P/19P transports signals on the RF layer in a way that multiple operators and multiple technologies are moved simultaneously from a cluster of base stations to a remote location over the same fiber.
The ION optical distribution system provides a coverage solution for dense urban areas, tunnels, subway, airports, convention centers, high-rise buildings and other locations where physical structures increase path loss. It has been specifically designed to reduce zoning problems and to provide homogeneous coverage. The compact, mechanical design is specifically architected to mount inside of poles or along side structures in such a way that it has a minimal visual impact.
The ION-M7P/85P/17P/19P is available in single or multi-band configuration supporting 700 MHz, 850 MHz, 1700 MHz/ 2100 MHz and 1900 MHz in parallel. It has been specifically tested and optimized for LTE, iDEN, GSM, EDGE, CDMA2000, EV-DO, WCDMA, HSPA+, and OFDMA. Furthermore, it is provisioned for future improvements to the modulation and frequency bands. In addition it is backwards compatible to legacy standards such as TDMA and Analog.
Page 15
Loading...
+ 35 hidden pages