Commax CDV-50P, CDV-50PD User Manual

Thank you for purchasing COMMAX products.
Please carefully read this User’s Guide (in particular, precautions for safety)
before using a product and follow instructions to use a product exactly.
The company is not responsible for any safety accidents caused by abnormal operation of the product.
Model No. : CDV-50P/50PD
Color Video Door Phone
Printed In Korea / 2008.05
http://www.safemag.ru
http://www.safemag.ru
Warnings and cautions . . . . . . . . . . . . . . . . . .2
1. Part Names and Functions . . . . . . . . . . .4
2. Operating description . . . . . . . . . . . . . . . . . .5
3. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
4. Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
5. Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
6. Package contents . . . . . . . . . . . . . . . . . . .10
7. Specification . . . . . . . . . . . . . . . . . . . . . . .11
!"#$% &' (&)*%)*+
1
http://www.safemag.ru
http://www.safemag.ru
3
If the socket holes are larger than normal, do not put the plug.
It may cause an electric shock or a fire.
Make sure that dust or foreign substances are not gathered on the product.
Make sure to prevent foreign substances from entering the product.
It may cause a breakdown.
Do not put a heavy object on the product.
It may cause a breakdown.
Do not disassemble or give an impact to the product.
Avoid direct rays of the sun or heating devices at a time of installation.
Install the product in a flat and stable place.
Otherwise, it may not function properly.
Pull the plug if the product is not used for a long time.
If the product generates strange sound, make sure to pull the plug immediately and contact Commax service center.
(("",,**--&&)
)
."/)-)0+1")213",*-&)+
I
t indicates prohibition. It indicates prohibition of disassembly. I
t indicates prohibition of contact. I
t indicates dos and don’ts. I
t indicates that the plug should be pulled out from the socket.
Caution
An injury or property losses are expected
!
!
Make sure to follow the instructions to prevent any danger or property losses.
Do not put the plug in the socket simultaneously.
It may generate abnormal heat or cause a fire.
Do not connect to other products while in use.
It may cause breakdown.
Do not forcibly bend the cord or put a heavy object on the prod­uct.
It may cause a fire.
Do not use water, thinner or a deter­gent used to wash oil products when you wash the exterior.
Make sure to wash it by using a dry cloth to prevent any breakdown or electricshock.
Do not install the product in a humid place.
It may cause an electric shock or a fire.
Do not forcibly pull out the cord from the socket.
If the cord is damaged, it may cause a fire or an electric shock.
Do not put the plug in the sock­et with a wet hand.
It may cause an electric shock.
Do not disassemble, repair or modify the product.
It may cause a fire, an electric shock or an injury due to malfunction of the product.
Do not use AC circuit breaker.
It may cause an electric shock.
..""//))--))0
0
."/)-)0+1")213",*-&)+
It indicates prohibition. It indicates prohibition of disassembly. It indicates prohibition of contact. It indicates dos and don’ts. I
t indicates that the plug should be pulled out from the socket.
Warning
D
eath or serious
i
njury is expected.
2
http://www.safemag.ru
http://www.safemag.ru
5
4
4516"/*1)"7%+1")21',)3*-&)+
No.
1
2
3
4
5
6
7
8
9
10
11
12
Part name
④ ⑤ ⑥ ⑦
⑧ ⑨
⑩ ⑪
Function description
Handset
Speaker
Screen
Power LED
Monitor button
Interphone button
Door open button
Hue control dial
Bright adjust dial
Volume control dial
Power on/off switch.
Handset connecti on jack.
The phone’s handset receiver
It delivers voice from a visitor
Check visitor’s image
Power status and door camera indication
View screen by door cameras
Talk to a interphone
Open the door
Adjust the hue of the screen
Adjust the brightness of the screen
Adjust of incoming call
Turn on / off switch
Plug in handset to this jack after installing the monitor
1. Visitor Calls
1) Talk to a visitor from a door camera
8519:%/"*-)012%+3/-:*-&)
① When a call is made by a door camera, you can hear its
chime sound and see visitor's picture from a monitor. If there is an interphone connected, you can talk to the visitor through it as well. Also three communications are available with a monitor, an interphone and a door camera on one line.
② Pick up the handset if you wish to talk.
Talk duration lasts for 90 seconds, press the "Monitor "
button if you wish to continue to talk ③ Press the "Open " button to release the door. ④ Hang up the handset to end the talk.
2. Interphone
. Press the "Interphone◎" button to call to a interphone. . The interphone rings, pick up the phone to talk.
2) Talk to a visitor from the second door camera while you talk to the first door camera
① The talk with the first door camera ends up automatically. ② The screen switches to display the visitor from the second door
camera and starts to talk with power LED in the orange color.
③ If you wish to talk back to the first door camera, press the
"Monitor " button.
3. Monitoring the door entrance for security
• You can monitor the door entrance by pressing the "Monitor "
button even if there is no call.
If there is somebody you see through the screen, you can talk with him or her through the handset.
• Press "Monitor " button again to switch to the other door
camera to monitor. Power LED color will be changed.
http://www.safemag.ru
http://www.safemag.ru
6
7
;51<)+*"$$"*-&)
󱄿 Note
• For the clearest picture quality, do not install a door camera under area that has a strong source of reflective light.
• Please keep cleaning its lens for the clearest pictures.
▷ Installation of CDV-50P/50PD
SCREW T4 X 18mm
S
CREW M3 X 6mm
SCREW T4(2EA)
SCREW M3
󱄿 Note
• Do not install near magnetic activity, humid temperatures, extreme heating conditions and under direct sunlight as these may damage the condition and performance of the product.
• The position of the unit’s body should fit the standard height range. (Recommended height rangen is 1450~1500mm)
▷ Installation of DRC-40CK
▷ Polarity of the camera connection.
1. Red : Talk
2. Blue : GND
3. Yellow : Power(+12V)
4. White : Video
=51.-/-)0
DOOR RELEASE
#1 (RE)
#2 (BL)
#3 (YE)
#4 (WH)
#1 (RE)
#2 (BL)
#3 (YE)
#4 (WH)
#1 (RE)
#2 (BL)
#3 (YE)
#4 (WH)
CAMERA 1 ①
CAMERA 2 ①
INTERPHONE ①
POWER SOURCE
POWER SOURCE
DOOR RELEASE
CDV-50PCDV-50P
CDV-50P
DRC-40CK
DP-4VH
http://www.safemag.ru
http://www.safemag.ru
8
9
󱄿 Note
1. Please be careful for mis-wiring and mis-cabling which may cause a short circuit between wires, or the malfunction of the product.
2.
Please power off when connecting a monitor (CDV-50P/50PD) to a door camera. (DRC-40CK)
DC17- 30V
S1 S2
DOOR RELEASE
#1 (RE)
#2 (BL)
#3 (YE)
#4 (WH)
#1 (RE)
#2 (BL)
#3 (YE)
#4 (WH)
#1 (RE)
#2 (BL)
#3 (YE)
#4 (WH)
CAMERA 1 ①
CAMERA 2 ①
INTERPHONE ①
POWER SOURCE
POWER SOURCE
DOOR RELEASE
CDV-50PCDV-50PD
CDV-50PD
DRC-40CK
DP-4VH
>151?-"0/"7
󱄾 When an addtionanl monitor and an interphone connection is added
to this system, this might affect audio and video quality.
DP-4VHDP-4VH
󱄾 Extendable
CDV-50P/50PDCDV-50P/50PD
DRC-40CK
DRC-40CK
4 4
44
44
http://www.safemag.ru
http://www.safemag.ru
@5116"3A"0%13&)*%)*+
① Monitor . . . . . . . . . . . . . . . . . .1EA
② Handset . . . . . . . . . . . . . . . . .1EA
③ Wall bracket for monitor . . . . . .1EA
④ Monitor fixing screw . . . . . . . . .1EA
⑤ Wall bracket mounting screw . . .2EA
⑥ Connector(4P) . . . . . . . . . . . . .2EA
⑦ Manual . . . . . . . . . . . . . . . . . .1EA
10
11
Screw T4 X 18 (2EA)
Screw M3 X 6mm (1EA)
B51C:%3-'-3"*-&)
Item
Rated Voltage
Power Consumption
Wiring
Screen Size
Transmission Way
Call Sound
On - Screen Duration
Distance from Camera
Operating Temperature
Weight
Dimension(mm)
CDV-50P
AC100~240V, 50/60Hz
Operating : 15W
4 wires with a door camera (Polarity)
4 wires with an interphone(Polarity)
Color 5″TFT LCD
Full duplex (Handset)
From a door camera : Electric chime, From an interphone : “Beep”
90 ± 20sec
28m(Ф0.5) / 50m(Ф0.65) / 70m(Ф0.8) 115m(Ф1)
0 ~ +40℃ (32°F ~ 104°F)
2Kg
258(W)× 159(H)× 51(D)
CDV-50PCDV-50PCDV-50PCDV-50P
Item
Rated Voltage
Power Consumption
Wiring
Screen Size
Transmission Way
Call Sound
On - Screen Duration
Distance from Camera
Operating Temperature
Weight
Dimension(mm)
CDV-50PD
DC17~30V, 1A
Operating : 14.2W(Max.)
4 wires with a door camera (Polarity)
4 wires with an interphone(Polarity)
Color 5″TFT LCD
Full duplex (Handset)
From a door camera : Electric chime, From an interphone : “Beep”
90
± 20sec
28m(
Ф
0.5) / 50m(Ф0.65) / 70m(Ф0.8) 115m(Ф1)
0 ~ +40℃ (32°F ~ 104°F)
2Kg
258(W)× 159(H)× 51(D)
CDV-50PCDV-50PCDV-50PCDV-50PD
http://www.safemag.ru