Commax CDL-200L User Manual

4.5 (2)
Commax CDL-200L User Manual
2. Press the [#] button twice in succession, then press
the 0 button.

CDL-200L

USER MANUAL

Durable Door lock without worry about A/S

Durable body of metal

Auto lock/rewind/double lock function

Use of 3D touch and imaginary function to secure password

Password/Smart key can be registered multiple

Multi-level volume control / Selectable silence function

Light button that is visible even in dark places

Emergency power function (9V square battery)

High-voltage protection/Fire protection/Anti-hack system

Intuitive registration UI

COMMAX Co., Ltd.

Thank you for purchasing COMMAX products.

Before you use, please read this manual

and use correctly. COMMAX is not responsible for any safety accident due to abnormal operation of the products.

Due to non-key door lock, it may cause destruction of digital door lock when it is in trouble.

Warning for Safety

These warnings are to secure user’s safety and prevent the possible loss of property. Please read carefully below to use the product in a correct manner.

*Do not disassemble, repair or modify the device by any unauthorized person.

*This product is for indoor, we do not guarantee any operation at other environment.

*Please use the product after reading User’s Manual.

*Do not press the buttons with any tools(Ex. Awl, Pins..)

*Change your access code from time to time for your safety.

*Do not impact on the device.

*Be careful that leakage or rupture may occur when inserting a battery in wrong direction.

*Be careful that water should not seep into the device.

*When replacing a battery, change all the batteries with new alkaline batteries.

*Please wipe the product with soft, dry towels.

*Please keep product warranty card for A/S.

*Do not use this product with other purposes except digital door lock function.

Products specifications and components

 

 

 

 

 

 

Sort

 

 

 

 

 

 

 

Specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Password

 

4-12 digits (Up to 4 can be registered)

 

 

 

 

 

 

Opening method

 

 

RF key

 

It can register within 30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wallpad interlock

 

Optional (CDL-447)

 

 

 

 

 

 

 

Rated voltage

 

 

DC 6V

 

LR6 1.5V AA sized alkaline batteries 8

 

 

 

 

 

Emergency power

 

 

DC 9V

 

Alkaline batteries 8 (Separate purchase)

 

 

 

 

 

 

 

Type of product

CDL-200LSKF(Fire-proof, temperature-sensitive form, key primary keylock / F-T-K-M)

 

 

 

 

 

 

 

CDL-200LSNF(Fire-proof, temperature-sensitive form, non-key, primary keylock / F-T-NK-M)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High temperature sensing

Temperature sensor type

 

60+-10 dgrees

 

 

 

 

 

 

 

material

 

 

Out body

 

AL,ZN,ABS,PC

 

 

 

 

 

 

 

 

 

In body

 

AL,ZN,ABS,PC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sort

Using frequency

Number of

Modulation

Antenna power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

channels

format

 

 

 

 

 

 

 

 

 

 

 

 

 

RFID

13.56Mhz

1

 

ASK

93.5dBu/under m@ 10m

 

 

 

Wireless devices for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

afety systems

447.275Mhz

1

 

FSK

10mW/under

 

 

 

 

 

 

(optional)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outbody

Inbody

Mortise & Stricker(Option1)

Big Mortise & Stricker(Option2)

Screw

Installation

User manual

8 Batteries Construction diagram

2 Emergency

Outdoor shaft

4 Smart key (Key formula only)

instruction

 

 

 

 

 

*The components of the product may change depending on the installation environment.

Outdoor Names and Functions

No

Name

Specifications

1

Name board

Enter the number whenregisteringor changingpassword.

2

Battery warninglight

Turnsonwith anaudible alarm at lowvoltage.

 

 

It isthe place where smart keysare recognizedtoopen

3

Smart key input unit

the door. You canopenthe door by registeringthe smart

 

 

key or touchingthe registeredsmart key.

4

Emergency hole

Key formula only (CDL-200LSKF)

5

Outdoor handle

It is Usedtoopenor close doorsfrom outdoors.

6

Emergency power terminal

Incase the battery is completely discharged, you can use

9Vbattery then, the power will be on.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9V emergency battery (Separate purchase)

How to register and change password

How to register the linker (optional)

Be sure to register your password with the door open.

1. Press

2. Press [3]button in the number

1. Press

2. Press [1]button in the number

[registration] button

plate of outdoor side

[registration] button

plate of outdoor side

 

 

Beep

Open the battery cover and press [registration]button

3. Enter new password

After entering the new password(4~12 digits), press * button and the confirmation tone sounds and registration is completed. Press the * button once more to end registration.

Reference

1.When adding the password, repeat the above item 3 before the number plate lamp turns off.

2.Up to 4 password can be registered

Cautions

1.If you register a new password, the existing password will be automatically deleted.

2.Do not use consecutive numbers when registering your password.

How to register Smart key

When registering or re-registering a smart key, you must register all the smart keys you have at once. Also registered smart keys are door lock only. It may not work when used with other products.

1. Press

2. Press [2]button in the number

[registration] button

plate of outdoor side

Beep

Open the battery cover and press [registration]button

3. Contact smart key to smart key input unit

If you touch the smart key to be registered one by one,

you will hear a confirmation sound every time you touch it.

Registration is completed by clicking the [Registration]

button on the indoor side body.

Reference

1.When adding the password, please repeat the above item 3 before the [License plate lamp] turns off.

2.Up to 30 smart keys can be registered.

Cautions

1. When registering a new smart key, the existing smart key is automatically deleted.

Beep

Open the battery cover and press [registration]button

3. Press the [Register] or [OP / CL] button on the linker

After pressing the front door button of the wall pad(video phone), press the [Registration] or [OP / CL] button of the interlocker when the standby mode is canceled.

Reference

1.You can register up to 5 interlocks.

2.Repeat step 3 when registering the linker.

How to delete smart key, linker

1. Press

2. Press number in the number plate

[registration] button

- Smart key deletion: No 7 button

 

 

- Deleting the interlock: No 8 button

Beep

Open the battery cover and press [registration]button

3. Press #button

Press and hold the [#] button for 5 seconds to delete the registered smart key or interlock.

How to set auto lock, manual lock

Make sure to turn off the Mortise Square Lock on the indoor body.

1. Enter password

2. Press [#]button

 

 

Touch the outdoor

 

 

Press the [#] button

 

 

 

 

 

 

license plate to turn

 

 

twice in succession

 

 

on the LED and

 

 

 

 

 

enter the registered

 

 

 

 

 

password.

 

 

 

3. Press [4] or [7]button and press registration button

Auto lock setting: Press the [4] button and press the register button to set the auto lock function after a confirmation tone sounds.

Manual lock setting: After pressing the [7] button and pressing the register button, the manual lock function is set after a tone is heard.

Indoor Names and Functions

No

Name

Specifications

1

Battery cover

This cover protects the batteries and the registration

button.

 

 

2

Interlocking pack

Receive (CDL-447, optional)

3

Registration button

It is used to register or change password or smart key

4

Mortise

It is attached to the side of the door and closes or locks the

door.

 

 

5

Dead bolt

It locks the door by locking it on the door frame.

(Square locking type)

6

Latch bolt

It serves to keep the door shaken

7

Alkalina AA battery

It is a power source that operates the door lock.

 

 

It can be used to lock the door so that it can not be opened

8

Double lock button

outside,such as during nighttime hours that require

 

 

attention.

9

Indoor handle

It is used to open or close the door indoors.

MORTISE TYPE

BIGMORTISE TYPE

How to set and dismiss 3D touch

1. Enter password

Touch the outdoor license plate to turn on the LED

and enter the registered password.

3. Press [Registration]button

When you press the [Registration] button on the outdoor

Beep

side body, the 3D touch function is turned on or off.

Open the battery cover and

- Set tone: Piriricic

press the [Registration] button.- Off sound: Piric

Reference

1.It is a function to strengthen the security of password and it is a function to set a virtual number instead of the original number when the password is registered and authenticated for more than 1 second.

Ex) When 1 is long pressed: It is recognized as a virtual number other than 1.

2.Combined with the imaginary function of this product, password security is further strengthened.

3.You can set each number and you can check that the lamp blinks when you press for more than 1 second.

4.3D touch mode is turned off at the factory.

Cautions

1.When the 3D touch mode is released, the password is reset to "1234".

2.In case of master registration / deletion, fire / accident, etc., it is recognized as normal number mode.

Open the door in outdoor

Method 1 Open the door by password

1. Enter password

2. Press [*]button

Touch the outdoor

When you press the

license plate to turn

[*] button, you will

on the LED and

hear a confirmation

enter the registered

tone and then open

password.

when you open

 

the door.