Commax CDL-88P User Manual

CDL-88P
USER MANUAL
Premium design Voice guidance function for customer convenience Durable door lock without worrying about A / S Durable body of metal Auto Lock / Relock / Dual Lock Safe use of passwords with 3D touch and imaginary functions Password / Smart Key Multiple Registration Multi-level volume control / selective mute function Light button for better visibility in dark places Emergency power supply using MICRO USB (TYPE-C) High voltage prevention / fire prevention / hacking prevention system Intuitive Registration UI
COMMAX Co., Ltd.
Thank you for purchasing COMMAX products.
Before you use, please read this manual and use
correctly. COMMAX is not responsible for any safety
accident due to abnormal operation of the products.
it may cause destruction of digital door lock when it is in trouble.
Due to non-key door lock,
Warning for Safety
These warnings are to secure user’s safety and prevent the possible loss of property. Please read carefully below to use the product in a correct manner.
* Do not disassemble, repair or modify the device by any unauthorized person. * This product is for indoor, we do not guarantee any operation at other environment. * Please use the product after reading User’s Manual. * Do not press the buttons with any tools(Ex. Awl, Pins..) * Change your access code from time to time for your safety. * Do not impact on the device. * Be careful that leakage or rupture may occur when inserting a battery in wrong direction. * Be careful that water should not seep into the device. * When replacing a battery, change all the batteries with new alkaline batteries. * Please wipe the product with soft, dry towels. * Please keep product warranty card for A/S. * Do not use this product with other purposes except digital door lock function.
Products specifications and components
Sort Specifications
Installation
condition
Opening
method
Rated voltage DC 6V LR6 1.5V Aasized alkaline batteries 8
Emergency power
Type of product
Size of prod uct
Operation guarantee temperature
High temperature
detection
Material
Outbody
8 Batteries
Construction diagram
General fire door door Thickness 40mm ~ 80mm
Password 4~12 digits (Up to 4 can be registered)
Smart Key It can regster within 30
Fingerprint It can regster within 100
Wallpad Interlock Optional(CDL-447)
Auxiliary battery
Fire-proof, Tempe raatu re-sensitive, Key, Primary keylock / D-F-T-K-M
Size 84 X 454 X 50 (H X V X T)
Weight 4.2 KG(Actual product standard)
Temperaature-sensitive
Outbody AL,ZN,ABS,PC
Inbody AL,ZN,ABS,PC
Inbody Mortise & Striker Screw
Smart key
4 Emergency
MICRO USB (TYPE-C)
- 40
℃ ~ 70℃
60℃ ± 10℃
Installation instruction
Outdoor shaft
User manual
* The components of the product may change depending on the installation environment.
Part Names and Functions
Number plate
Open notification light Fingerpirnt input unit
Registration UI
Smart key input unit
Battery warning light Close notification light
Internal double locking button
Outdoor handle
Reset button
Emergency power terminal (5V MICRO USB TYPE-C)
Emergency key hole
Battery cover
Registration button(R)
Indoor handle
Deadbolt
Handle shaft Insertion
Latchbolt
Inbody
hole cover
How to register fingerprint
1. Press [registration] button
Beep
Open the battery cover and press [registration]button
3. Contact fingerprint to be registered to fingerprint input unit
Reference
1. Up to 100 fingerprints can be registered.
2. If registration is not in progress for 20 seconds,
registration will be canceled.
How to register and change password
Be sure to register your password with the door open.
1. Press [registration] button
Beep
Open the battery cover and press [registration]button
3. Enter new password
Reference
1. When adding the password, repeat the above item 3
before the number plate lamp turns off.
2. Up to 4 password can be registered
Cautions
1. If you register a new password, the existing password
will be automatically deleted.
2. Do not use consecutive numbers when registering your
password.
2. Press [1]button in the number plate of outdoor side
After contacting the fingerprint to the fingerprint input part four times, register the registration by pressing the [register] button on the room body.
2. Press [2]button in the number plate of outdoor side
After entering the new password(4~12 digits), press * button and the confirmation tone sounds and registration is completed. Press the * button once more to end registration.
How to register Smart key
1. Press [registration] button
Beep
Open the battery cover and press [registration]button
3. Contact smart key to smart key input unit
If you touch the smart key to be registered one by one, you will hear a confirmation sound every time you touch it. Registration is completed by clicking the [Registration] button on the indoor side body.
Reference
1. When adding the smart key, please repeat the above item 3 before the
[Number plate lamp] turns off.
2. Up to 30 smart keys can be registered.
Cautions
1. When registering a new smart key, the existing smart key is automatically deleted.
2. Press [3]button in the number plate of outdoor side
How to register the linker (optional)
1. Press [registration] button
Beep
Open the battery cover and press [registration]button
3. Press the [Register] or [OP / CL] button on the linker
After pressing the front door button of the wall pad(video phone), press the [Registration] or [OP / CL] button of the interlocker when the standby mode is canceled.
Reference
1. You can register up to 5 interlocks.
2. Repeat step 3 when registering the linker.
2. Press [4]button in the number plate of outdoor side
How to delete fingerprint, smart key, inetrlock
1. Press [registration] button
Beep
Open the battery cover and press [registration]button
3. Press #button
2. Press number in the number plate
- Smart key deletion: No 7 button
- Deleting the interlock: No 8 button
- Delete fingerprint: No 9 button
Press and hold the [#] button for 5 seconds to delete the registered fingerprint, smart key or interlock.
How to set auto lock, manual lock
Make sure to turn off the Mortise Square Lock on the indoor body. (In the autolock mode, touch the outdoor number plate for 2 seconds to unlock the square lock..)
1. Enter password 2. Press [#]button
Touch the outdoor license plate to turn on the LED and enter the registered password.
Press the [#] button twice in succession
3. Press [4] or [7]button and press registration button
1. Auto lock setting: Press the [4] button and press the [registration] button to set the auto lock function after a confirmation tone sounds.
2. Manual lock setting: After pressing the [7] button and pressing the [registration] button, the manual lock function is set after a tone is heard.
Internal double lock setting
It is a function that can not open a door with a password or a smart key outside the door.
Setting
설정방법
1. While the door is locked, press and hold the [double lock] button for 3 seconds
If you press and hold the [double lock] button for 3 seconds, the setting is completed with "OK" sound.
How to release internal
1. Push the knob from inside to open the door
2. Press the [Double lock] button inside and dismiss
How to release outdoor
1.
Input Password
Touch the outdoor number plate and then enter the registered password.
2.
Press [#], [9] button
Press [#] then press [9], internal dual lock is off with beep sound
Open the door in outdoor
Method 1
1. Enter password 2. Press [*]button
Method 2
1. Contact smart key to smart key input unit
Open the door by password
Touch the outdoor license plate to turn on the LED and enter the registered password.
When you press the [*] button, you will hear a confirmation tone and then open when you open the door.
Open door with smart key
When the registered [Smart Key] is touched to the smart key input part, a confirmation tone is heard and it opens when you open the door.
Reference
1. When using a separately registered credit / traffic guard other than the provided tag key, touch the license plate on the outdoor side to turn on the [number plate lamp] and touch the card and tag key to open the door.
How to set and dismiss 3D touch
1. Enter password 2. Press the [#] button twice in
Touch the outdoor license plate to turn on the LED and enter the registered password.
3. Press [Registration]button
When you press the [Registration] button on the outdoor
Beep
Open the battery cover and press the [Registration] button.
side body, the 3D touch function is turned on or off.
- Set tone: Piriricic
- Off sound: Piric
succession, then press the 0 button.
Set lock Indoor Outdoor
2 seconds after
seconds after door closes
on the indoor side body
during 2 secods
Reference
1. It is a function to strengthen the security of password
and it is a function to set a virtual number instead of the
original number when the password is registered and
authenticated for more than 1 second.
Ex) When 1 is long pressed: It is recognized as a virtual
number other than 1.
2. Combined with the imaginary function of this product,
password security is further strengthened.
3. You can set each number and you can check that the
lamp blinks when you press for more than 1 second.
4. 3D touch mode is turned off at the factory.
Cautions
1. When the 3D touch mode is released, the password is
reset to "1234".
2. In case of master registration / deletion, fire / accident, etc.,
it is recognized as normal number mode.
Reference
* What is imaginary function? Door opens even if you enter a random number with a password Ex) Password “1234” Imaginary and password input: 5231234, 1234253, 45123402
Door locking in indoor and outdoor
Auto lock
Manual lock
Automatically locked after
Press the [double lock] button
Reference
1. When you press [double lock] button in manual lock
mode, you will hear a "beep" buzzer sound when the door
is locked and inform you that the door is lockedv.
Locked automatically after 2
Touch the number plate
Dual authentication / Registration authentication setting
1. Input password
Touch number plate. When LED lights on, input registered password
2. Press [#] button twice, press [1] or [8] button.
[1] : Dual authentication [8] : Registration authentication
3. Press [Regist.] button.
Once press [Regist.] button on outdoor body, Dual authentication or registration authentication
Open the battery cover and
Beep
press [registration]button
mode is on or off. Active: Sound - Bee ri ri rik Deactive: Sound - Bee rik
Reference
1. If dual authentication mode is activated, Password +
Card should be confirmed to open to door.
(door open by BLE keeps available.)
2. If registration authentication mode is activated,
first authentication by existing password should be done
for the next step.
* No dual authentication / registration authentication is
activated if factory setting.
* To deactivate dual authentication / registration
authentication, repeat the same procedure for activation
Volume Adjustment
Deadbolt of indoor unit must be come out from mortise before setting
How to
1. Input Password
When LED lights on after touching number plate, input registered password
2. Press [#] button
3. Press [3] or [6] to adjust volume
[3] for volume up [6] for volume down
Reference
1. Available total 8 levels of volume sound
2. If sound pause mode, numbers are only flicking
without sound
Battery Replacement Alert
If battery alert light is on on number plate or beep sounds ring, battery has to be replaced. All batteries must be replaced with new one at once.
Burglar Alert
If door to be opened by abnormal operation such as door gap break through, burglar alert rings with more than 80db noisy sound.
How to deactivate burglar or temperature alert
Remove batteries or [password + *] , [smartkey touch], [contact fingerprint] * if temperature is too high, no deactivation.
Voice guidance settings
1. Input password
Touch number plate. When LED lights on, input registered password
3. Press [Regist.] button.
Beep
Open the battery cover and press [registration]button
Once press [Registration] button on indoor body, Voice guidance settings mode is on or off. Active: Sound - Bee ri ri rik Deactive: Sound - Bee rik
2. Press [#] button twice, press [3] button.
High Temperture Alarm
Once extremely high temperature is detected (60℃± 10℃), locker is automatically released to open the door with huge sound to secure user’s safety.
Emergency Power
When door can not be opened due to fully discharged battery.
1. Connect the auxiliary battery to the MICRO USB PORT (TYPE-C) of the outdoor body to turn on the emergency power.
Emergency Key
When door is not opened due to malfunction.
You can release the lock by inserting the emergency key in the emergency key insertion section at the bottom of the body and rotating it to the left or right.
Caution
1.Your mechanical key is recommended to be stored
outside of the door for emergency use.
Sound Pause Mode
Temporary silence function (1 time) regardless latest volume setting
How to
1. Touch number plate and press [#]
2. Press [*] after password or, contact Card / Fingerprint to open the door.
Reference
Sound is back to the original volume if pause mode is operated once
Factory Reset Mode
1. Press [Regist.] button. 2. Input “123578951” when number plate lights on
BEEP
Open the battery cover and press [Regist.] button for 5 secs
3. Press [#] button for 2 secs.
Factory default mode is completed with beep sound.
Caution
1.All settings back to the default after factory reset
Anti-mischief alert and 1 minute pause
If unregistered [password], [smartkey], [fingerprint] keeps used more than 5 times
continuously, freeze operation for 1 minute with alert sound.
Try 5 times in a row??
Reference
1. To deactivate alert sound, open the door from indoor body
handle
2. If mechanical key is available, deactivate alert sound by key
Deadbolt Jam alert
When deadbolt is jammed during door open/close, alert sound of bee bee bee bee” rings 3 times.
Caution
1.If no sound deactivation or door lock malfunction,
product installed position has to be adjusted.
Please contact your local installer or service provider.
Door Open Alert during automatic lock setting
To inform door open status during automatics lock setting, alert sound rings 2 times with each 15 seconds interval if door opened.
Caution
1. Lifetime of battery can be varied according to
manufacturers, date of production, working condition.
(Expected lifetime : 10 months assuming no wireless
operation, AA type alkaline 8ea, 10 times per one day use)
2. If battery liquid leaks out, product can be damaged. Regular checking is recommended – every 6 months.
3. Battery lifetime might be shortened if wireless module
is activated.
Self-Diagnosis Table by each LED number flicking
To see the status of product by means of checking flicking number
ACTION SELF-DIAGNOSIS
Flicking ALL LEDs - Anti-mischief alert and 1 minute pause
Flicking LED number 2 - Error on password, smart key, fingerprint set
Flicking LED number 3
Flicking LED number 4 - Deadbolt Jam
Flicking LED number 5 - Burglar Alert
Flicking LED number 6 - Unregistered password, smart key, fingerprint
Flicking LED number 7 - Already registered address(Nanual register mode)
Flicking LED n
Flicking LED number 9 - Internal double lock
Flicking LED number 0 - Malfunction of fingerprint module
umber 8 - Fire Alarm
- Full of registered password, smart key
-
Full of registered fingerprint or no fingerprint registered
Summary of how to use
Fun ct io n D ef au lt
Fingerprint registration
Delete
all fingerprints
Password
registration/change
Card registration
Delete all card [Regist ration] ⇒ [7] ⇒ [
Wallpad interlock
registration
Delete the all interlocking [Registration] ⇒ [8] ⇒ [#] More than 5 seconds
Open the door indoors Door lock handle: Push the internal handle
Close the door indoors
Open the door outdoors
Close the door outdoors
Auto lock setting Password ⇒ [#] [#] ⇒ [4] ⇒ [Registration]
Manual lock setting Password ⇒ [#] [#] ⇒ [7] ⇒ [Reg
Set dual
authenitication mode
Set registration
authenitication mode
3D touch
authenitication mode
Internal dual lock LED setting Of f Password ⇒ [#] [#] ⇒ [5] ⇒ [Registration]
Voice guidance setting On Password ⇒ [#] [#] ⇒ [3] ⇒ [Registration]
Internal doub
le lock setting Hold the internal [double lock] for 3 seconds
Release internal double lock
Etiquette mode function Password: [#] ⇒ Enter Password ⇒ [*]
Buzz
er volume setting
Release alram sound
[Registration] ⇒ [1] ⇒ Fingerprint registration 4 times ⇒ [Registration]
[Registration] ⇒ [9] ⇒ [#] More than 5 seconds
1234 [Registration] ⇒ [2] ⇒ Password to Registration ⇒ [*]
[Registration] ⇒ [3] ⇒ Card (tag) recognition (Continuous registration) ⇒ [Registration]
[Registration] ⇒ [4] ⇒ Remote control [OP / CL]⇒ [Registration]
Auto lock: Auto lock when the door is closed Manual Lock: the internal [Double lock] Fingerprint: Fingerprint contact to fingerprint Registrat ion Password: LED(number plate) ON ⇒ Enter Password ⇒ [*] Card: Card contact with Registrationed card recognition Emergency key: Rotate after inserting emergency key into emergency key insertion part Auto lock: Auto lock when the door is closed Manual locking: Touch the number plate of outdoor
Auto lock
Off Password ⇒ [#] [#] ⇒ [1] ⇒ [Registration]
Off Password ⇒ [#] [#] ⇒ [8] ⇒ [Registration]
Off Password ⇒ [#] [#] ⇒ [0] ⇒ [Registration]
Indoors: Push [double lock] and push handle Outdoors: Password ⇒ [#] ⇒ the [9]
Treble: Enter Password ⇒ [#] ⇒ [3] Bass: Input Password ⇒ [#] ⇒ [6] Indoor: When battery is removed Outdoors: Password, card authentication
#] More than 5 seconds
istration]
Loading...