CDL-210P/210R
USER MANUAL
Durable Door lock without worry about A/S
Durable body of metal
Auto lock/rewind/double lock function
Use of 3D touch and imaginary function to secure password
Password/Smart key/Fingerprint can be registered multiple
Multi-level volume control / Selectable silence function
Light button that is visible even in dark places
Emergency power function (9V square battery)
High-voltage protection/Fire protection/Anti-hack system
Intuitive registration UI
COMMAX Co., Ltd.
Products specifications and components
Sort Specifications
Opening method
Rated volt age DC 6V LR6 1.5V AA sized alkaline batteries 8
Emergency power DC 9V Alkaline batteri es 8 (Separate purchase)
Type of product
High temperature sensing Temperature sensor ty pe 60+-10 dgrees
material
Sort Using frequency
RFID 13.56Mhz 1 ASK 93.5dBu/u nder m@ 10m
Wireless devic es for
afety syste ms
(optional)
Outbody
Inbody
Password 4-12 digit s (Up t o 4 can be registered)
RF key It can register wit hin 30
Fingerprin t It can register wit hin 100
Wallpad interlock Optional (CDL-447)
CDL-210P SKF(Fire-proof, temperature-sensitive form, key primary keylock / F-T-K-M)
CDL-210PSNF(Fire-p roof, temperature-sensitive form, non-key, primary keylo ck / F-T-NK-M)
Out body AL,ZN,ABS,PC
In body AL,ZN,ABS,PC
Number of
channels
447.275Mh z 1 FSK 10mW/under
Mortise & Stricker(Option1) Screw
Modulation
format
Big Mortise & Stricker(Option2)
Antenna power
Indoor Names and Functions
No Name Specif ications
1 Battery cove r
2 Interlocking pack Receive (CDL-447, optional)
3 Registration button It is used to register or change password or smart key
4 Mortise
5
6 Latch bolt It serves to keep t
7 Alkalina AA battery It is a power source that operates the door lock.
8 Double lock button
9 Indoor handle It is used to open or close the door indoors.
Dead bolt
(Square locking type)
MORTISE TYPE
This cover protects the batteries and the registrati on
button.
It is attached to the side of the door and closes or locks the
door.
It locks the door by locking it on the door frame.
It can be used to lock the door so that it can not be opened
outside,such as during nighttime hours that require
attention.
he door shaken
BIGMORTISE TYPE
Thank you for purchasing COMMAX products.
Before you use, please read this manual and use
correctly. COMMAX is not responsible for any safety
accident due to abnormal operation of the products.
Due to non-key door lock, it may cause
destruction of digital door lock when it is in trouble.
Warning for Safety
These warnings are to secure user’s safety and prevent the possible loss of property.
Please read carefully below to use the product in a correct manner.
* Do not disassemble, repair or modify the device by any unauthorized person.
* This product is for indoor, we do not guarantee any operation at other environment.
* Please use the product after reading User’s Manual.
* Do not press the buttons with any tools(Ex. Awl, Pins..)
* Change your access code from time to time for your safety.
* Do not impact on the device.
* Be careful that leakage or rupture may occur when inserting a battery in wrong direction.
* Be careful that water should not seep into the device.
* When replacing a battery, change all the batteries with new alkaline batteries.
* Please wipe the product with soft, dry towels.
* Please keep product warranty card for A/S.
* Do not use this product with other purposes except digital door lock function.
Installation
instruction
User manual
8 Batteries
Construction diagram
4 Smart key
2 Emergency
(Key formula only)
Outdoor shaft
*The components of the product may change depending
on the installation environment.
Outdoor Names and Functions
No Name Specifications
1 Name board Enter the number when registering or changing password.
2 Battery warning light Turns on with an audible alarm at low voltage.
3 Smart key input unit
4 Emergency hole Key formula only (CDL-210PSKF)
5 Outdoor handle It is Used to
6 Emergency power terminal
7 Fingerpirnt input unit
9V emergency battery
(Separate purchase)
It is the place where smart keys are recognized to open the
door. You can open the door by registering the smart key or
touching the registered smart key.
open or close doors from outdoors.
In case the battery is completely discharged, you can use
9V battery then, the power will be on.
You can register your fingerprint, open the door by using
the fingerprint registered.
How to register fingerprint
1. Press
[registration] button
Beep
Open the battery cover and
press [registration]button
3. Contact fingerprint to be registered to fingerprint input unit
After contacting the fingerprint to the fingerprint
input part four times, register the registration
by pressing the [register] button on the room body.
Reference
1. Up to 100 fingerprints can be registered.
2. If registration is not in progress for 20 seconds,
registration will be canceled.
2. Press [1]button in the number
plate of outdoor side
How to register and change password
Be sure to register your password with the door open.
1. Press
[registration] button
2. Press [2]button in the number
plate of outdoor side
Beep
Open the battery cover and
press [registration]button
3. Enter new password
After entering the new password(4~12 digits),
press * button and the confirmation tone sounds
and registration is completed. Press the * button
once more to end registration.
Reference
1. When adding the password, repeat the above item 3
before the number plate lamp turns off.
2. Up to 4 password can be registered
Cautions
1. If you register a new password, the existing password
will be automatically deleted.
2. Do not use consecutive numbers when registering your
password.
How to register Smart key
When registering or re-registering a smart key, you must register
all the smart keys you have at once. Also registered smart keys are
door lock only. It may not work when used with other products.
1. Press
[registration] button
Open the battery cover and
press [registration]button
Beep
3. Contact smart key to smart key input unit
If you touch the smart key to be registered one by one,
you will hear a confirmation sound every time you touch it.
Registration is completed by clicking the [Registration]
button on the indoor side body.
Reference
1. When adding the password, please repeat the above
item 3 before the [License plate lamp] turns off.
2. Up to 30 smart keys can be registered.
Cautions
1. When registering a new smart key, the existing smart
key is automatically deleted.
2. Press [3]button in the number
plate of outdoor side
How to register the linker (optional)
1. Press
[registration] button
Open the battery cover and
press [registration]button
Beep
3. Press the [Register] or [OP / CL] button on the linker
After pressing the front door button of the wall pad(video phone),
press the [Registration] or [OP / CL] button of the interlocker
when the standby mode is canceled.
Reference
1. You can register up to 5 interlocks.
2. Repeat step 3 when registering the linker.
How to delete fingerprint, smart key, linker
1. Press
[registration] button
Open the battery cover and
press [registration]button
Beep
3. Press #button
Press and hold the [#] button for 5 seconds to delete
the registered fingerprint, smart key or interlock.
How to set auto lock, manual lock
Make sure to turn off the Mortise Square Lock on the indoor body.
1. Enter password 2. Press [#]button
3. Press [4] or [7]button and press registration button
Touch the outdoor
license plate to turn
on the LED and
enter the registered
password.
Auto lock setting: Press the [4] button and press the register
button to set the auto lock function after a confirmation
tone sounds.
Manual lock setting: After pressing the [7] button and pressing
the register button, the manual lock function is set after a tone
is heard.
2. Press [4]button in the number
plate of outdoor side
2. Press number in the number plate
- Smart key deletion: No 7 button
- Deleting the interlock: No 8 button
- Delete fingerprint: No 9 button
Press the [#] button
twice in succession
How to set and dismiss 3D touch
1. Enter password 2. Press the [#] button twice in
Touch the outdoor
license plate to
turn on the LED
and enter the
registered password.
succession, then press
the 0 button.
3. Press [Registration]button
When you press the [Registration] button on the outdoor
Beep
Open the battery cover and
press the [Registration] button.
side body, the 3D touch function is turned on or off.
- Set tone: Piriricic
- Off sound: Piric
Reference
1. It is a function to strengthen the security of password
and it is a function to set a virtual number instead of the
original number when the password is registered and
authenticated for more than 1 second.
Ex) When 1 is long pressed: It is recognized as a virtual
number other than 1.
2. Combined with the imaginary function of this product,
password security is further strengthened.
3. You can set each number and you can check that the
lamp blinks when you press for more than 1 second.
4. 3D touch mode is turned off at the factory.
Cautions
1. When the 3D touch mode is released, the password is
reset to "1234".
2. In case of master registration / deletion, fire / accident, etc.,
it is recognized as normal number mode.
Open the door in outdoor
Method 1
1. Enter password 2. Press [*]button
Open the door by password
Touch the outdoor
license plate to turn
on the LED and
enter the registered
password.
When you press the
[*] button, you will
hear a confirmation
tone and then open
when you open
the door.
Method 2
Open door with smart key
1. Contact smart key to smart key input unit
When the registered [Smart Key] is touched to the
smart key input part, a confirmation tone is heard
and it opens when you open the door.
Method 3
Open door by interlocking(Optional)
1. Press the [OP/CL] button on the interlock
Press the [OP / CL] button on the interlock to
open the door.
Door locking in indoor and outdoor
Set lock Indoor Outdoor
Auto lock
Manual lock
Automatically locked after
2 seconds after
Press the [double lock] button
Locked automatically after 2
seconds after door closes
Touch the number plate
during 2 secods
Deactivation from outdoor unit
1. Input Password 2. Press [#], [9] button
When LED lights
on, input password
Press [#] then press [9],
indoor dual lock is off
with beep sound
Dual authentication / Registration authentication setting
1. Input password 2. Press [#] button twice,
Touch number
plate. When LED
lights on, input
registered
password
3. Press [Regist.] button.
Beep
Open the battery cover and
press [registration]button
press [1] or [8] button.
[1] : Dual authentication
[8] : Registration
authentication
Once press [Regist.] button on outdoor body,
Dual authentication or registration authentication
mode is on or off.
Active: Sound - Bee ri ri rik
Deactive: Sound - Bee rik
Volume Adjustment
Deadbolt of indoor unit must be come out from mortise before setting
How to
1. Input Password 2. Press [#] button
When LED lights on
after touching
number plate,
input registered
password
3. Press [3] or [6] to adjust volume
[3] for volume up
[6] for volume down
Reference
1. Available total 8 levels of volume sound
2. If sound pause mode, numbers are only flicking
without sound
Reference
1. When you press [double lock] button in manual lock
mode, you will hear a "beep" buzzer sound when the door
is locked and inform you that the door is lockedv.
Internal double lock setting
It is a function that can not open a door with a password or a smart
key outside the door.
Setting
1. While the door is locked, press and hold the [double lock]
button for 3 seconds
If you press and hold the [DUAL LOCK] button for
3 seconds, the setting is completed with "OK" sound.
How to release internal
1. Push or pull the knob
from inside to open the door
CDL-210P CDL-210R
2. Press the [double lock]
button inside and dismiss
Reference
1. If dual authentication mode is activated, Password +
Card should be confirmed to open to door.
(door open by BLE keeps available.)
2. If registration authentication mode is activated,
first authentication by existing password should be done
for the next step.
* No dual authentication / registration authentication is
activated if factory setting.
* To deactivate dual authentication / registration
authentication, repeat the same procedure for activation
Burglar Alert
If door to be opened by abnormal operation such
as door gap break through, burglar alert rings
with more than 80db noisy sound.
How to deactivate burglar or temperature alert
Remove batteries or [password + *] , [smartkey touch], [contact fingerprint]
* if temperature is too high, no deactivation.
Battery Replacement Alert
If battery alert light is on on number plate or beep sounds ring, battery has to
be replaced. All batteries must be replaced with new one at once.
Caution
1. Lifetime of battery can be varied according to
manufacturers, date of production, working condition.
(Expected lifetime : 10 months assuming no wireless
operation, AA type alkaline 8ea, 10 times per one day use)
2. If battery liquid leaks out, product can be damaged.
Regular checking is recommended – every 6 months.
3. Battery lifetime might be shortened if wireless module
is activated.
Sound Pause Mode
Temporary silence function (1 time) regardless latest volume setting
How to
1. Touch number plate and press [#]
2. Press [*] after password or, contact Card / Fingerprint to
open the door.
Reference
Sound is back to the original volume if pause mode is
operated once
High Temperture Alarm
Once extremely high temperature is detected
(60℃± 10℃), locker is automatically
released to open the door with
huge sound to secure user’s
safety.
Emergency Power
When door can not be opened due to fully discharged battery.
1. Contact the terminals of 9V battery to emergency power outlet
Press [Password] and [ * ] to open the door while contacting
terminals of 9V battery to emergency power outlet.
Factory Reset Mode
1. Press [Regist.] button. 2. Input “123578951” when
number plate lights on
BEEP
Open the battery cover and
press [Regist.] button for 5 secs
3. Press [#] button for 2 secs.
Factory default mode is completed with beep sound.
Caution
1.All settings back to the default after factory reset
Anti-mischief alert and 1 minute pause
If unregistered [password], [smartkey], [fingerprint] keeps used more than 5 times
continuously, freeze operation for 1 minute with alert sound.
Try 5 times
in a row??
Door Open Alert during automatic lock setting
To inform door open status during automatics lock
setting, alert sound rings 2 times with each 15 seconds
interval if door opened.
Self-Diagnosis Table by each LED number flicking
To see the status of product by means of checking flicking number
ACTION SELF-DIAGNOSIS
Flicking ALL LEDs - Anti-mischief alert and 1 minute pause
Flicking LED number 2 - Error on password, card, fingerprint set
Flicking LED number 3
Flicking LED number 4 - Deadbolt Jam
Flicking LED number 5 - Burglar Alert
Flicking LED number 6 - Unregistered password, card, fingerprint
Flicking LED number 7 - Already r e
Flicking LED number 8 - Fire Alarm
Flicking LED number 9 - Dual lock from Indoor unit
Flicking LED number 0 - Malfunction of fingerprint module
- Full of r egistered fingerprint.
- Full of r egistered password, card
gistered address
Summary of how to use
9V emergency battery
(sold separately)
Emergency Key
When door is not opened due to malfunction.
Open the bottom cover of outdoor body to use
mechanical key box. Key-in to open the door
for emergency release.
Caution
1.Your mechanical key is recommended to be stored
outside of the door for emergency use.
Reference
1. To deactivate alert sound, open the door from indoor body
handle
2. If mechanical key is available, deactivate alert sound by key
Deadbolt Jam alert
When deadbolt is jammed during door
open/close, alert sound of
bee bee bee bee” rings 3 times.
Caution
1.If no sound deactivation or door lock malfunction,
product installed position has to be adjusted.
Please contact your local installer or service provider.
Function Default
Fingerprint registration [Registration] button ⇒ [1] button ⇒ Fingerprint registration 4 times ⇒ [Registration] button
Delete all fingerprints [Registration] button ⇒ [9] button ⇒ [#] button More than 5 seconds
Password change 1234 [Registration] button ⇒ [2] button ⇒ Password to register ⇒ [*] button ⇒ [*] button
Card registration None [Registration] button ⇒ [3] button ⇒ Card (tag) recogni
Delete all card [Registration] button ⇒ [7] button ⇒ [#] button More than 5 seconds
Interlocking registration None [Registration] button ⇒ [4] button ⇒ Remote control [OP / CL]⇒ [Registration] button
Delete the all interlocking [Registration] button ⇒ [8] button ⇒ [#] button More than 5 seconds
Open the door indoors D oor lock handle: Push the manual opening
Close the door indoors
Open the door outdoors
Close the door outdoors
Auto lock setting Enter the password ⇒ Press the [#] [#] button ⇒ Press the [4] button ⇒ Press the [Registration] button
Manual lock s etting Enter the password ⇒ Press the [#] [#] button ⇒ Press the [7] button ⇒ Press the [Registration] button
Set dual authenitication mode Release
Set registration
authen
itication mode
3D touch authenitication mode Release
Internal dual lock LED setting Release Enter the password ⇒ Press the [#] [#] butto
Internal force lock setting Press and hold the [Internal force lock] button for 3 seconds
Release internal force lock
Etiquette mode function Normal mode Password: Press [#] button ⇒ Enter password ⇒ Press [*] button
Buzzer volume setting
Release alram sound
Automatic locking
Auto lock: Auto lock when the door is closed
Manual Lockin g: Press the [Internal Dual Locking] button
Password: LED of window number LED ON ⇒ Enter password ⇒ Press [*] button
Card: Card contact with card recognition
Emergency key: Rotate after inserting emergency key into Emergency key insertion part
Auto lock: Auto lock when the door is closed
Manual locki ng: Touch t
Enter the password ⇒ Press the [#] [#] button ⇒ Press the [1] button (Individual authentication / Dual authentication)
⇒ Click the [Registration] button
Enter the password ⇒ Press the [#] [#] button ⇒ Press the [8] button (General registration / double registration)
Release
⇒ Click the [Registration] button
Enter the password ⇒ Press the [#] [#] button ⇒ Press the [0] button ⇒ Press the [Registration] button
Set sound (beep sound), release soun d (beep sound)
Indoors: manual opening and clos ing with door open and door closing
Outdoors: Enter the password ⇒ Press the [#] button ⇒ Press the [9] button
Treble: Enter p
Bass: Input pass word ⇒ Press [#] button ⇒ Press [6] button ⇒ Press [*] button
Indoor: When battery is removed
Outdoors: Password, card authentication
he license plate of the window for 2 seconds
assword ⇒ Press [#] button ⇒ Press [3] button ⇒ Press [*] button
tion (Continuous registration) ⇒ [Registration] button
/ closing device towards the door.
n ⇒ Press the [5] button ⇒ Press the [Registration] (On/Off)