Products specifications and components
9 Indoor handle It is used to open or close the door indoors.
Indoor Names and Functions
CDL-200L
USER MANUAL
Durable Door lock without worry about A/S
Durable body of metal
Auto lock/rewind/double lock function
Use of 3D touch and imaginary function to secure password
Password/Smart key can be registered multiple
Multi-level volume control / Selectable silence function
Light button that is visible even in dark places
Emergency power function (9V square battery)
High-voltage protection/Fire protection/Anti-hack system
Intuitive registration UI
COMMAX Co., Ltd.
Thank you for purchasing COMMAX products.
Before you use, please read this manual
and use correctly. COMMAX is
not responsible for any safety
accident due to abnormal
operation of the products.
Due to non-key door lock, it may cause
destruction of digital door lock when it is in trouble.
Warning for Safety
These warnings are to secure user’s safety and prevent the possible loss of property.
Please read carefully below to use the product in a correct manner.
* Do not disassemble, repair or modify the device by any unauthorized person.
* This product is for indoor, we do not guarantee any operation at other environment.
* Please use the product after reading User’s Manual.
* Do not press the buttons with any tools(Ex. Awl, Pins..)
* Change your access code from time to time for your safety.
* Do not impact on the device.
* Be careful that leakage or rupture may occur when inserting a battery in wrong direction.
* Be careful that water should not seep into the device.
* When replacing a battery, change all the batteries with new alkaline batteries.
* Please wipe the product with soft, dry towels.
* Please keep product warranty card for A/S.
* Do not use this product with other purposes except digital door lock function.
Sort Specifications
Password 4-12 digits (Up to 4 can be registered)
Opening method
Rated voltage DC 6V LR6 1.5V AA sized alkaline batteries 8
Emergency power DC 9V Alkaline batteries 8 ( Separate purchase)
Type of product
High temperature sensing Temperature sensor type 60+-10 dgrees
material
Sort Using frequency
RFID 13.56Mhz 1 ASK 93.5dBu/u nder m@ 10m
Wireless devic es for
afety syste ms
(optional)
Outbody
Installation
instruction
Inbody
User manual
CDL-200LSKF(Fire-proof, temperature-sensitive form, key primary keylock / F-T-K-M)
CDL-200LSNF(Fire-p roof, temperature-sensitive form, non-key, primary keylo ck / F-T-NK-M)
447.275Mh z 1 FSK 10mW/under
Mortise & Stricker(Option1) Screw
8 Batteries
RF key It can register within 30
Wallpad interlock Optional ( CDL-447)
Out body AL,ZN,ABS,PC
In body AL,ZN,ABS,PC
Number of
channels
Construction diagram
Modulation
format
Big Mortise & Stricker(Option2)
4 Smart key
2 Emergency
(Key formula only)
Antenna power
*The components of the product may change depending
on the installation environment.
Outdoor Names and Functions
No Name Specifications
1 Name board Enter the number when registering or changing password.
2 Battery warning light Turns on with an audible alarm at low voltage.
It is the place where smart keys are recognized to open
3 Smart key input unit
4 Emergency hole Key formula only (CDL-200LSKF)
5 Outdoor handle It is Used to
6 Emergency power terminal
9V emergency battery
(Separate purchase)
the door. You can open the door by registering the smart
key or touching the registered smart key.
open or close doors from outdoors.
In case the battery is completely discharged, you can use
9V battery then, the power will be on.
Outdoor shaft
1 Battery cover
2 Interlocking pack Receiv e (CDL-447, optional)
3 Registration button It is used to register or change password or smart key
4 Mortise
5
6 Latch bolt It serves to keep the door shaken
7 Alkal
8 Double lock button
Dead bolt
(Square locking type)
ina AA battery It is a power source that operates the door lock.
This cover protects the batteries and the registration
button.
It is attached to the side of the door and closes or locks the
door.
It locks the door by locking it on the door frame.
It can be used to lock the door so that it can not be opened
outside,such as during nighttime hours that require
attention.
MORTISE TYPE
How to register and change password
Be sure to register your password with the door open.
1. Press
[registration] button
2. Press [1]button in the number
plate of outdoor side
Beep
Open the battery cover and
press [registration]button
3. Enter new password
After entering the new password(4~12 digits),
press * button and the confirmation tone sounds
and registration is completed. Press the * button
once more to end registration.
Reference
1. When adding the password, repeat the above item 3
before the number plate lamp turns off.
2. Up to 4 password can be registered
Cautions
1. If you register a new password, the existing password
will be automatically deleted.
2. Do not use consecutive numbers when registering your
password.
How to register Smart key
When registering or re-registering a smart key, you must register
all the smart keys you have at once. Also registered smart keys are
door lock only. It may not work when used with other products.
1. Press
[registration] button
Open the battery cover and
press [registration]button
Beep
3. Contact smart key to smart key input unit
If you touch the smart key to be registered one by one,
you will hear a confirmation sound every time you touch it.
Registration is completed by clicking the [Registration]
button on the indoor side body.
Reference
1. When adding the password, please repeat the above
item 3 before the [License plate lamp] turns off.
2. Up to 30 smart keys can be registered.
Cautions
1. When registering a new smart key, the existing smart
key is automatically deleted.
2. Press [2]button in the number
plate of outdoor side
How to register the linker (optional)
1. Press
[registration] button
Open the battery cover and
press [registration]button
Beep
3. Press the [Register] or [OP / CL] button on the linker
After pressing the front door button of the wall pad(video phone),
press the [Registration] or [OP / CL] button of the interlocker
when the standby mode is canceled.
Reference
1. You can register up to 5 interlocks.
2. Repeat step 3 when registering the linker.
How to delete smart key, linker
1. Press
[registration] button
Open the battery cover and
press [registration]button
Beep
3. Press #button
Press and hold the [#] button for 5 seconds to delete
the registered smart key or interlock.
How to set auto lock, manual lock
Make sure to turn off the Mortise Square Lock on the indoor body.
1. Enter password 2. Press [#]button
3. Press [4] or [7]button and press registration button
Touch the outdoor
license plate to turn
on the LED and
enter the registered
password.
Auto lock setting: Press the [4] button and press the register
button to set the auto lock function after a confirmation
tone sounds.
Manual lock setting: After pressing the [7] button and pressing
the register button, the manual lock function is set after a tone
is heard.
2. Press [3]button in the number
plate of outdoor side
2. Press number in the number plate
- Smart key deletion: No 7 button
- Deleting the interlock: No 8 button
Press the [#] button
twice in succession
BIGMORTISE TYPE
How to set and dismiss 3D touch
1. Enter password 2. Press the [#] button twice in
Touch the outdoor
license plate to
turn on the LED
and enter the
registered password.
succession, then press
the 0 button.
3. Press [Registration]button
When you press the [Registration] button on the outdoor
Beep
Open the battery cover and
press the [Registration] button.
side body, the 3D touch function is turned on or off.
- Set tone: Piriricic
- Off sound: Piric
Reference
1. It is a function to strengthen the security of password
and it is a function to set a virtual number instead of the
original number when the password is registered and
authenticated for more than 1 second.
Ex) When 1 is long pressed: It is recognized as a virtual
number other than 1.
2. Combined with the imaginary function of this product,
password security is further strengthened.
3. You can set each number and you can check that the
lamp blinks when you press for more than 1 second.
4. 3D touch mode is turned off at the factory.
Cautions
1. When the 3D touch mode is released, the password is
reset to "1234".
2. In case of master registration / deletion, fire / accident, etc.,
it is recognized as normal number mode.
Open the door in outdoor
Method 1
1. Enter password 2. Press [*]button
Open the door by password
Touch the outdoor
license plate to turn
on the LED and
enter the registered
password.
When you press the
[*] button, you will
hear a confirmation
tone and then open
when you open
the door.
Method 2
Open door with smart key
1. Contact smart key to smart key input unit
When the registered [Smart Key] is touched to the
smart key input part, a confirmation tone is heard
and it opens when you open the door.
Method 3
Open door by interlocking(Optional)
1. Press the [OP/CL] button on the interlock
Press the [OP / CL] button on the interlock to
open the door.
Door locking in indoor and outdoor
Set lock Indoor Outdoor
Auto lock
Manual lock
Automatically locked after
2 seconds after
Press the [double lock] button
Locked automatically after 2
seconds after door closes
Touch the number plate
during 2 secods
Deactivation from outdoor unit
1. Input Password 2. Press [#], [9] button
Touch number
plate. When LED
lights on, input
registered
password
Press [#] then press [9],
indoor dual lock is off
with beep sound
Dual authentication / Registration authentication setting
1. Input password 2. Press [#] button twice,
Touch number
plate. When LED
lights on, input
registered
password
3. Press [Regist.] button.
Beep
Open the battery cover and
press [registration]button
press [1] or [8] button.
[1] : Dual authentication
[8] : Registration
authentication
Once press [Regist.] button on outdoor body,
Dual authentication or registration authentication
mode is on or off.
Active: Sound - Piriricic
Deactive: Sound - Piric
Volume Adjustment
Deadbolt of indoor unit must be come out from mortise before setting
How to
1. Input Password 2. Press [#] button
When LED lights on
after touching
number plate,
input registered
password
3. Press [3] or [6] to adjust volume
[3] for volume up
[6] for volume down
Reference
1. Available total 8 levels of volume sound
2. If sound pause mode, numbers are only flicking
without sound
Reference
1. When you press [double lock] button in manual lock
mode, you will hear a "beep" buzzer sound when the door
is locked and inform you that the door is lockedv.
Internal double lock setting
It is a function that can not open a door with a password or a smart
key outside the door.
Setting
1. While the door is locked, press and hold the [double lock]
button for 3 seconds
If you press and hold the [DUAL LOCK] button for
3 seconds, the setting is completed with "OK" sound.
How to release internal
1. Open the door by releasing
the knob inside and releasing it
2. Press the [double lock]
button inside and dismiss
Reference
1. If dual authentication mode is activated, Password +
Card should be confirmed to open to door.
(door open by BLE keeps available.)
2. If registration authentication mode is activated,
first authentication by existing password should be done
for the next step.
* No dual authentication / registration authentication is
activated if factory setting.
* To deactivate dual authentication / registration
authentication, repeat the same procedure for activation
Burglar Alert
If door to be opened by abnormal operation such
as door gap break through, burglar alert rings
with more than 80db noisy sound.
How to deactivate burglar or temperature alert
Remove batteries or [password + *] , [smartkey touch]
if temperature is too high, no deactivation.
Battery Replacement Alert
If battery alert light is on on number plate or beep sounds ring, battery has to
be replaced. All batteries must be replaced with new one at once.
Caution
1. Lifetime of battery can be varied according to
manufacturers, date of production, working condition.
(Expected lifetime : 10 months assuming no wireless
operation, AA type alkaline 8ea, 10 times per one day use)
2. If battery liquid leaks out, product can be damaged.
Regular checking is recommended – every 6 months.
3. Battery lifetime might be shortened if wireless module
is activated.
Sound Pause Mode
Temporary silence function (1 time) regardless latest volume setting
How to
1. Touch number plate and press [#]
2. Press [*] after password or, contact Card to open the door.
Reference
Sound is back to the original volume if pause mode is
operated once
High Temperture Alarm
Once extremely high temperature is detected
(60℃± 10℃), locker is automatically
released to open the door with
huge sound to secure user’s
safety.
Emergency Power
When door can not be opened due to fully discharged battery.
1. Contact the terminals of 9V battery to emergency power outlet
Press [Password] and [ * ] to open the door while contacting
terminals of 9V battery to emergency power outlet.
9V emergency battery
(sold separately)
Emergency Key
When door is not opened due to malfunction.
Open the cover on the handle of the outdoor body
If you insert the emergency key and turn to the left or right
You can release the lock status.
Caution
1.Your mechanical key is recommended to be stored
outside of the door for emergency use.
Factory Reset Mode
1. Press
[Registration] button.
BEEP
Open the battery cover and
press [Registration] button for 5 secs
3. Press [#] button for 2 secs.
Factory default mode is completed with beep sound.
Caution
1.All settings back to the default after factory reset
Anti-mischief alert and 1 minute pause
If unregistered [password], [smartkey] keeps used more than 5 times
continuously, freeze operation for 1 minute with alert sound.
Try 5 times
in a row??
Reference
1. To deactivate alert sound, open the door from indoor body
handle
2. If mechanical key is available, deactivate alert sound by key
2. Input “123578951” when
number plate lights on
Deadbolt Jam alert
When deadbolt is jammed during door
open/close, alert sound of
bee bee bee bee” rings 3 times.
Caution
1.If no sound deactivation or door lock malfunction,
product installed position has to be adjusted.
Please contact your local installer or service provider.
Door Open Alert during automatic lock setting
To inform door open status during automatics lock
setting, alert sound rings 2 times with each 15 seconds
interval if door opened.
Self-Diagnosis Table by each LED number flicking
To see the status of product by means of checking flicking number
ACTION SELF-DIAGNOSIS
Flicking ALL LEDs -Anti-mischief alert and 1 minute pause
Flicking LED number 2 -Error on password, card set
Flicking LED number 3
Flicking LED number 4 - Deadbolt Jam
Flicking LED number 5 - Burglar Alert
Flicking LED number 6 - Unregistered password, card
Flicking LED number 7 - Already registered address
Flicking LED number 8 - Fire Alarm
Flicking LED
Flicking LED number 0
number 9 - Dual lock from Indoor unit
- Full of r egistered password, card
Summary of how to use
Function Default
Password change 1234
Card registration None
Delete all card
Interlocking registration None
Delete the all interlocking
Open the door indoors
Close the door indoors
Open the door outdoors
Close the door outdoors
Auto lock setting
Manual lock setting
Set dual
authenitication mode
Set registration
authenitication mode
3D touch authenitication mode Release
Internal dual lock LED setting Release
Internal force lock setting Press an d hold the [Internal force lock] button for 3 seconds
Release internal force lock
Etiquette mode function Normal mode Password: Press [#] button ⇒ Enter password ⇒ Press [*] button
Buzzer volume setting
e alram sound
Releas
Automatic
[Registration] button ⇒ [1] button ⇒ Password to register⇒ [*] button⇒ [*] button
[Registration] button ⇒ [2] button ⇒ Card (tag) recognition
(Continuous registration) ⇒ [Registration] button
[Registration] button ⇒ [7] button ⇒ [#] button More than 5 seconds
[Registration] button ⇒ [3] button ⇒ Remote cont
⇒ [Registration] button
[Registration] button ⇒ [8] button ⇒ [#] button More than
5 seconds
Door lock handle: Push the manual opening / closing device towards the door.
Auto lock: Auto lock when the door is closed
Manual Locking: Press the [Internal Dual Locking] button
Password: LED of window number LED ON ⇒ Enter password ⇒ Press [*] button
Card: Card contact with card recognition
Emergency key: Rotate after inserting emergency key into Emergency key insertion part
Auto lock: Auto lock when the door is closed
Manual lockin g: Touch the license plate of the window for 2seconods
Enter the password ⇒ Press the [#] [#] button ⇒ Press the [4] button ⇒
Press the [
Registration
locking
Enter the password ⇒ Press
Press the [
Enter the password ⇒ Press the [#] [#] button ⇒ Press the [1] button
Release
(Individual authen tication / Dual authentication)
⇒ Click the [
Enter the password ⇒ Press the [#] [#] button ⇒ Press the [8] button
Release
(General registration / double registration)
⇒ Click the [
Enter the password ⇒ Press the
Press the [
Set sound (beep sound), release sound (beep sound)
Enter the password ⇒ Press the [#] [#] button ⇒ Press the [5] button ⇒
Press the [
Indoors: manual opening and closi ng with door open a
Outdoors: Enter the password ⇒ Press the [#] button ⇒ Press the [9] button
Treble: Enter password ⇒ Press [#] button ⇒ Press [3] button
Bass: Input password ⇒ Press [#] button ⇒ Press [6] button
Indoor: When battery is removed
Outdoors: Password, card authentication
Registration
Registration
Registration
Registration
Registration
] button
the [#] [#] button ⇒ Press the [7] button ⇒
] button
] button
] button
[#] [#] button ⇒ Press the [0] button ⇒
] button
] (On/Off)
rol [OP / CL]
nd door closing