Commax CDL-107U User Manual

CDL-107U
USER MANUAL
CAUTION
Be sure the door is open when you first register or change the passcode as the door may accidentally lock during the process. Please change your passcode regularly and re-register your passcode immediately if you think someone else has gained access to it. If you lose any of the registered cards, please delete all registered cards immediately.
Registering Master Passcode [4~10 Digits / Default: 1234]
Register the passcode to be used. Only one master passcode can be registered.
Beep
Beeri
Beeririri
Auto Lock Setting
Beep-Tiri
Press the [R] button for 3 seconds
If you keep the door unlocked after setting the auto lock, the door unlock beeps twice
Beep
Press the [4] button briefly
Beeririri
Press the [R] button briefly
Auto Lock Feature
Beeririri
WARNING
No door lock can guarantee its own security or safety by itself. You should contact an authorized locksmith or other security specialist to reduce the risk of intrusion from damage caused by force or technical means and to enhance security.
Thank you for purchasing CDL-107U This manual is designed to make the product more convenient and safe to use. Please read it carefully before using this product.
WWW.COMMAX.CO.KR
Package Contents
Exterior Unit : Identified by the keypad screen, installed on the outer part of door Interior : Identified with the battery cover, installed on the interior part of door Unit Number Pad : Displays numbers for password entry and recognizes compatible RFID objects Emergency Power Contact : Power can be supplied from the outside using a 9 Volt battery Registration [R]Button : This button allows you to access all the functions and settings for this door lock Thumb-Turn :You can manually unlock and lock your deadbolt using the turn lever Lock Button : Used for locking when in “Manual Lock Mode” and also used for the “Double Lock” feature Magnetic Sensor : This sensor allows the doorlock to know when the door is closed so that it can automatically lock Battery Cover : Battery cover of interior unit Battery : 4 pcs of AA 1.5V LR6 Alkaline Battery Interior Plate : This plate is used to hold the exterior panel onto the door. It is also used to connect the interior panel to the door Card : ISO14443A-Part3 RFID Card
M4X40mm Screw (3EA) : These screws are used to hold the exterior panel to the “Interior Plate” M4X6mm Screw (3EA) : These screws are used to hold the Interior Unit to the “Interior Plate”
4X20mm Screw Tapping (2EA) : Used to securely attach the magnetic sensor to the door frame Magnet : Do not misplace! This piece is crucial for your automatic locking function. Losing it may also cause other malfunctions. User Manual : Instruction for users Install Guide : Instruction for installation
Press the [R] button briefly
Enter the new Passcode [4~10 digits]
Press the [ ] button and re-enter the
Passcode
Press the [R] button briefly
If you register a new passcode, the existing registered passcode will be automatically changed
Opening the Door with a Passcode
Beep
Touch the Number Pad
Enter the Passcode then press the [ ] button
Reference: Anti-Peek Feature
If you are concerned about passcode exposure, you may enter a random number before entering your passcode.[up to 20 digits included passcode] i.e) (up to 16 random digits) + (your passcode: 1234 [ ]) In order to use OTP, BLE Pack must be installed to enable unlock on OTP . Please refer to enclosed BLE registration and user manual
Beeririring
After unlock the deadbolt then open the door
Registering a RFID Card or Key Tag
Up to 30 RFID user cards can be registered including smartphone NFC. The same card will not be registered twice during registration.
Beep
Press the [R] button briefly
Beeringbeering Beeringbeering
Tag Key Card
Touch the Card reader with the Card to register
When the 2580 flashes, the next card to be registered is touched continuously
Tag Key Card
Beeririring
Press the [R] button briefly
Opening the Door with a RFID Card or Key Tag
Beep
Tag Key Card
Beeririring
Door open state [Distance between the sensor and the magnet]
The door lock sensor may not operate due to malfunction of the magnet sensor. Be sure the door is locked when the door is closed.
When door closed,the sensor recognizes the magnet and automatically locks in 2 seconds.
Manual Lock Setting
Beep-Beeri
Press the [R] button for 3 seconds
the magnetic sensor does not sound when the door is closed, the door does not lock. In order to lock the door, touch the number plate for 2 seconds or thumb-turn to lock the door when closing the door.
4
Beep
Press the [7] button briefly
Press the [R] button briefly
Automatic Re- Lock Feature
If you do not open the door after unlocking it with a passcode or card, the door locks automatically after 7 seconds.
Double Authentication Mode Setting(On) [Passcode and Card must be registered]
Beep-Beeri
Beep
Beeri
7
Beeririring
CAUTION
As with any radio-based technology, it should be noted that the accuracy and reliability of the COMMAX lock's in-and outside sensor cannot be guaranteed. Users should not rely solely on the COMMAX lock's sensor for security purposes and should always use caution. This manufacturer assumes no responsibility for incorrect results or damages resulting from the use of the COMMAX lock's sensor. Certain home configurations may impede the COMMAX lock's sensor more than others.
CAUTION
The setting and operation of each function may not be able to be implemented due to the loss of function (malfunction), natural disaster, arbitrary change, etc.depending on the installation environment and frequency of use. Please read User Manual and Install Guide before using the product
CAUTION
Please be careful with personal information by using BLE
CAUTION
Please observe the following precautions in order to avoid injury or damage to property
Do not install outdoors in the rain Do not disassemble or reassemble it as it may cause malfunction. Do not use any tools to subject the product to excessive force Your password and card should be managed carefully Please make sure that the door is properly locked when you leave Do not spray directly with water or clean it with chemicals such as benzene, thinner, or alcohol
ge Contents
Packa
Exterior Unit
Interior Unit
Number Plate
Door Status (Door Open)
Care Reader
Reset Switch
Door Status (Door Close)
Low Voltage Indicator LED
Emergency Teminal
+ +
Battery Cover
Batteries
+ +
Registration [R ]Button
Lock Button
Thumb-Turn
Interior Plate with back pad
+
+
M4x40 [3EA]
M4x6 [3EA]
4x20
[4EA]
Mechanical key
Magnetic Sensor
Magnet
Quick Manual
MORTISE
Tag Key Card
[4EA]
CDL-107U
USER MANUAL
WARNING
No door lock can guarantee its own security or safety by itself. You should contact an authorized locksmith or other security specialist to reduce the risk of intrusion from damage caused by force or technical means and to enhance security.
Thank you for purchasing CDL-107U This manual is designed to make the product more convenient and safe to use. Please read it carefully before using this product.
WWW.COMMAX.CO.KR
User Manual
STRIKER
Spring
Install Guide
Z-wave Pack
Adapter [+]
+
+
Batteries
Tapping
After unlock the deadbolt
Touch the Card reader with a registered Card
If the card surface is metallic, the recognition rate may be significantly degraded or not recognized. The card may not be recognized depending on the smartphone attachment. When using Sticker Type Card, you need to turn off NFC function on the smartphone.
then open the door
Registering Smartphone NFC Card [Only available with BLE models]
Beep
Beep
Beeririring
NFC
Press the [R] button briefly
To use smartphone nfc feature, install the BLE app, enable nfc mode, wake up your smartphone and use it.
Press the [#] button once
When the 2580 flashes, Touch the Card reader with Smartphone NFC
Beeririri
Press the [R] button briefly
Opening the Door with a Smartphone NFC Card
Beep
Touch the Number Pad
Delete all Registered Cards
Beep-Beeri
Press the [R] button for 3 seconds
Please delete and re-register your cards if you lost a/any RFID Card(s) for security purposes.
Beep
Press the [#] button once
Press the [8] button briefly
Beeririring
NFC
When the 2580 flashes, Touch the Card reader with Smartphone NFC
Beep
Press the [#] button for 5 seconds
Beeririring
After unlock the deadbolt then open the door
Beep-tiririring
Delete Individual Registered Card
Beep-Beeri
Tiririring
Tag Key Card
NFC
Press the [R] button for 3 seconds
Please keep your passcode and card registration safe. If the registered passcode or card is deleted or not recognized, it is recommended to register or reset immediately.
Touch the card reader with the RFID Card or NFC card to delete
BeeringBeering
Press the [R] button briefly
Press the [R] button for 3 seconds
After double authentication mode is set up, enter the password first and then touch the card to unlock the door.
If the card isn’t registered, Double authentication mode is not set up.
If you delete registered card, Double Authentication mode is set off
Double Authentication Mode Off
Beep-Beeri
Press the [R] button
52
for 3 seconds
Registration Authentication Mode Setting (On)
Beep-Beeri
Press the [R] button for 3 seconds
If registration authentication mode is set up, you will hear 2 beep sounds when you press the [R] button.
Registration Authentication Mode Off
Beep-Beeri-Beepbeep
Press the [R] button for 3 seconds
If you turn off registration authentication mode, registered guest passcode will be automatically deleted.
[When the registration authentication mode is on] The guest passcode function is activated and the double lock mode is automatically off Press the [R] button first, then enter the passcode and touch [ ] key to enter registration mode
63
Beeri
Enter the Master Passcode then press the [ ] button
Press the [5] button briefly
Beep
Press the [5] button briefly
Beep
Press the [6] button briefly
Beep
Press the [6] button briefly
Press the [R] button briefly
Beeri
Press the [R] button briefly
Beeririring
Press the [R] button briefly
Press the [R] button briefly
8
Beeri
9
Registering Guest Passcode [Maximum10 Guests]
Beep-Beebi
Press the [R]
button briefly
Beeri Beeri
Enter the Guest Passcode to be registered [4~10 digits]
You can not set the any function with the guest passcode, only unlock the door by
the guest passcode. When Registration authentication mode is set up, it cans use guest passcode. If you register a new guest passcode in the existing registered address, the existing guest passcode will be deleted.
Beeri
Enter the master Passcode then [ ] button
Press the [ ] button briefly
Enter the Guest Code assignment (50~59) [50,51,52,...,59]
Re-Enter the Guest Passcode again
Delete Individual Guest Passcode
Beep-Beeri-Beepbeep
Press the [R] button for 3 seconds
Beeri
Enter the master Passcode then [ ] button
Enter the Guest Code assignment to be deleted.
Beeri
Press the [#] button briefly
Beeririring
Press the [R] button briefly
Beeririring
Press the [#] button for a second
High Temperature Alarm
If an alarm occurs during an internal fire or a high temperature, the door will automatically unlock. The alarm sounds for 3 minutes continuously. [Inside temperature : 158 F 41 F] Temperature may vary depending on installation environment It will be off when it is authenticated by registered passcode or cards. It will be off when the battery is removed.
Trespass Alarm
When the door is forcibly unlocked or abnormally unlocked, an audible alarm sounds for 3 minutes continuously. It will be activated after 7 seconds from door lock. It will be off when it is authenticated by registered passcode or cards. It will be off when the battery is removed.
Soft Reset [All settings are reset except BLE & Z-Wave]
If you suspect that your security is weak due to the leakage of your password or the loss of your
registered card, we will reset your registered password and card to improve security. [When deleting BLE information, delete it from APP of registered smartphone.]
If you do Soft Reset, all settings are reset except BLE & Z-wave information.
Beep-Beeri-Beeribeeri-Beeribeeribeeri
Beeririring
Passcode Error Locked Alarm
An error sounds when authentication is attempted with an unregistered password or card, if 5 times authentication errors occur, an alarm sounds and all operations stop for 3 minutes.
Low Voltage (Battery) Notification Alert
If a battery shortage is detected, the alarm sounds during unlock or lock and the low voltage red light indicator on the number pad will blink.
Replace the batteries immediately If the battery is fully discharged, open the door with Emergency Power Contact and 9V battery(6LR61)
Tiringtiring-Tiringtiring-Tiringtiring
5
fa il
STOP
Press the [R] button for 9 seconds
It is recommended to use it when registering incorrectly while setting.
Factory Reset [A ll settings are reset except BLE]
Beep-Beeri-Beeribeeri-Beeribeeribeeri
Press the [1,4,7,8,9,6,3] button sequentially
Press the [R] button briefly
Beeririring
Deadbolt Jam Warning
If the deadbolt does not work properly cause installed incorrectly or mechanically, the alarm sounds when unlocking or locking the door.
Tiringtiring-Tiringtiring-Tiringtiring
Emergency Power Contact
Contact the 9V Battery(6LR61) to Emergency Power Contact Enter the passcode or card in contact state
9V Battery(6LR61)
9V
[Not Included]
6LR61
When buying a 9V battery, please purchase replace batteries together
[Change Batteries Spec : 1.5V LR6 AA Size ALKALINE(4ea)]
10
13
Press the [R] button for 9 seconds
If you do Factory Reset, all settings are reset except BLE information. It is recommended to use it when registering incorrectly while setting.
Default Value of User & Factory Reset
Master Passcode
Volume level
Auto/Manual Lock
Double Auth
Registration Auth
High[3]
Press the [1,2,3,6,5,4,7] button sequentially
1234
Auto
Off
Off
Press the [R] button briefly
After initialization, please register a new
Passcode and Cards again.
16
Delete A ll Guest Passcode
Beeri
Press the [R] button for 3 seconds
If you turn off registration authentication mode, registered guest passcode will be automatically deleted.
Enter the master Passcode then [ ] button
Enter [00]
Outgoing Security Mode Feature
After the door is locked, touch the number pad in for 3 seconds
An alarm sounds when someone try to open the door by Thumb-Turn from the inside. It does not work when the magnetic sensor is faulty, malfunction or not recognized the magnet.
While touching, the number pad is flashed three times at intervals of one second, and the mode is set up.
It will be released when open the door with a passcode or card from the outside.
Internal Security Mode Feature
Beep-Beeririring
To Activate(ON):
Press and hold the [LOCK] button for 3 seconds while the door is locked.
To OFF: Press the [LOCK] button briefly or unlock the door by Thumb-Turn then open the door
You can not unlock the door with a registered passcode or card from the outside. It does not work when the magnetic sensor is faulty, malfunction or not recognized the magnet.
It can not be released even if the door is opened with the emergency key.
Beeririring
Press the [#] button for 5 seconds
Z-Wave Activation [Module Sold Separately]
While your Hub is in pairing mode, follow these steps. #Z-Wave Module must be intalled
Beep-Beeri-Beeribeeri
Z-Wave
Press the [R] button for 6 seconds
If the communication connection is not established within 10 seconds, the registration will be canceled. Please try again.
When Registration Authontication mode is set, holding the button for 6 seconds will flash the number pad twice.
When the door unlock / lock using communication, it may not perform the operation due to communication error. Please check unlock / lock status.
Press the [1,4,7] button sequentially
Beeririri
Z-Wave
Press the [R] button briefly
Connecting Communication beetween Z-wave Module and Smarthome Gateway
Controll using Z-Wave through Smart Home APP
Press [Unlock] button to unlock from Smart Home APP Press [Lock] button to lock from Smart Home APP
Delete Z-Wave Communication
Beep-Beeri-Beeribeeri
Z-Wave Z-Wave
Press the [R] button for 6 seconds
The CDL-107U Z-Wave is a secure electronic door lock that supports the Z-Wave Plus standard, which is compatible with earlier versions of Z-Wave. A security enabled Z-Wave controller must be use. The CDL-107U supports the standard security S0 and the new security standard S2. The CDL-107U can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network
Press the [3,6,9] button sequentially
Beeririri
Press the [R] button briefly
Deleting Communication beetween Z-wave Module and Smarthome Gateway
Bee
Regulatory Compliance
This product complies with standards established by the following regulatory bodies:
Federal Communications Commission (FCC)
Industry Canada
FCC
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet ona circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/ TV technician for help.
IMPORTANT ! Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
FCC Radiation Exposur e Statement
The equipment complies with FCC Radiation exposure limits set forth for uncontrolled environment. This equipment should be installed and operated with minimum distance 50 mm
Industr y Canada
This device complies with Industry Canada licenceexempt RSS standard(s). Operation is subject to the following two conditions: ( 1 ) this device may not cause interference, and ( 2 ) this device must accept any interference, including interference that may cause undesired operation of the device. This device complies with ISED radiation exposure limits set forth for an uncontrolled environment and meets the ISED radio frequency (RF) Exposure Guidelines. It is desirable that it should be installed and operated keeping the radiator at least 50 mm or more away from person’s body.
Canada, avis d’Industrie Canada (IC)
Cet appareil est conforme aux normes RSS exemptes de licenced’Industrie Canada. Son utilisation est soumise aux deux conditions. suivantes : (1) cet appareil n’engendre pas d’interférences, et (2) cet appareil doit tolérer tout type d’interférences, notamment les interférences pouvant provoquer une utilisation non désirée del’appareil. Cet équipement est conforme aux limites établies par Industrie Canada en matière d’exposition aux radiations dans un environnement non contrôlé. Cet équipement doit être installé et utilisé avec une distance minimale de 50 mm entre le radiateur et votre corps.between the radiator and your body.
1411
17
Volume Control Setting
Beep-Beebi
Press the [R] button for 3 seconds
Select and press the desired volume among 1,2,3 on the Number Pad [1]Silent, [2]Low, [3]High
Beeririring
Press the [R] button briefly
Etiquette Mode Feature
When the door is locked, touch and hold the Number Pad for one second, it will be set when the Number Pad flashes once.
It is one-time function, It will operate normally with the volume set after unlock and lock the door
Enter the Passcode or touch the card when the Number Pad is on
system sounds are muted for one-time entry
Anti-Peek Feature [Hidden Passcode]
If you are concerned about passcode exposure, you may enter a random number before entering your passcode.[up to 20 digits included passcode] i.e) If your passcode is 1234: (up to 16 random digits) + (your passcode: 1234 [ ])
Touch the Number Pad then the Pad on
Enter any other number first then enter the registered passcord at the last.
Press the [ ] button to open the door
BLE(Bluetooth Low Energy) Setting [Optional] BLE module must be installed
Press [Unlock] button to unlock from Smartphone APP(KeyWe) Press [Lock] button to lock from Smartphone APP(KeyWe)
BLE Setting and Manual
1. Search and download APP[KeyWe] from Apple APP Store or Google Play Store
2. Open the KeyWe APP and sign up with email
3. Door Lock Registration
KeyWe
- Open the KeyWe APP and sign in
- Press the Menu button in the upper left corner and select the Connect Door Lock
- Click the [+] button and click the Continue on QR Code
- Scan the QR Code inside of the battery space to register BLE module
- Register door lock name and location
4. Controll through KeyWe APP
- Open the KeyWe APP and connect the BLE module
- When the connection is complete, it displays the status of the door lock.
- Pressing the center of the screen changes the state of the door lock.
Other Functions
- Setting Smart Phone NFC in the KeyWe Menu and APP Setting
- Setting OTP(One time passcode) in the Door Lock Setting
- Deleting Door Lock in the Door Lock Setting
- For more information on APP, refer to the following site.(FAQ->APP)
[http://keywe.thekeywe.com/index_kor.php]
Make sure Optional Module is installed
Z-Wave & BLE Code
The Z-wave or BLE information is enclosed in the box. Please attach it directly to the product or inside of the battery cover before or after registration.
You can not re-register when you lose the code information. [Z-wave & BLE code] If connection is not established, re-insert the communication module or check the pins are damaged.
Specification
Exterior
Interior
Battery
Card
76.4mm(W) X 164.7mm(H) X 43mm(D)
71.3mm(W) X 151.8mm(H) X 39mm(D)
4 X AA Alkaline 1.5V Batteries (LR6) (6V)
The battery life is 15 months when used 10 times a day.
Battery usage time may vary depending on the installation environment and frequency of use.
CDL-107U SETTING SUMMARY
Setting
Master Passcode Setting
Registering Card
Delete Card
Auto Lock
Manual Lock
Double Auth Mode On Double Auth Mode Off
Registration Auth Mode On Registration Auth Mode Off
Reg. Guest Passcode
[in Reg. Auth mode On]
Delete Guest Passcode
[Indivisual]
Delete Guest Passcode
[All]
Outgoing Security
Mode On
Internal Security Mode On
Internal Security Mode Off
Volume [Silent]
Volume [Low] Volume [High]
Registration Z-wave
Delete Z-wave
Soft Reset
Factory Reset
1512
Specification RemarkContants
Polycabonate & Al Diecasting
Polycabonate & Zn Diecasting
ISO14443A PART3 TYPE
(b): Press briefly
(#S): Press and hold for # seconds, (ex. (3S): Press and hold for 3 seconds)
Defualt
[R](b) -> Passcode -> [ ] -> Passcode again -> [R](b)
1234
[R](b) -> Touch Card (continuous registration) -> [R](b)
None
[R](3S) -> [8] -> [#](5S)
[R](3S) -> [4] -> [R](b)
Auto
[R](3S) -> [7] -> [R](b)
[R](3S) -> [5] -> [R](b)
Off
[R](3S) -> [5] -> [R](b)
[R](3S) -> [6] -> [R](b)
Off
[R](3S) -> Master Passcode -> [ ] -> [6] -> [R](b)
[R](b) -> Master Passcode -> [ ] -> Guest code assignment [50~59] -> [#]
None
-> Guest passcode to be reg. -> [ ] -> Guest passcode again -> [R](b)
[R](3S) -> Master Passcode -> [ ] -> Guest code assignment to be deleted [50~59]
None
[#](1S)->
[R](3S) -> Master Passcode -> [ ] -> [00] -> [#](5S)
None
After the door is locked, touch and hold the number pad in for 3 seconds
The number pad is flashed three times->
Off
Press and hold the [LOCK] button for 3 seconds while the door is locked
Off
Turn the Thumb-Turn or press the [LOCK] button
[R](3S) -> [1] -> [R](b) [R](3S) -> [2] -> [R](b)
High
[R](3S) -> [3] -> [R](b)
[R](6S) -> [147] -> [R](b)
Off
[R](6S) -> [369] -> [R](b)
[R](9S) -> [1478963] -> [R](b)
Factory
[R](9S) -> [1236547] -> [R](b)
Mode
Volt : DC 6V
Operating Temperature : -25~50 C
High Temperature : 70 C 5 C
Sensor Operating
Summary
Page
10
10
11
11
11
11
12 12 12
14 14
16 16
4
5 6
7 7
8 8
9 9
18