Comark C9551 User Manual [en, de, es, fr, it]

OPERATING INSTRUCTIONS
FOR COMARK C9500 SERIES
PRESSURE METERS
ENGLISH
DEUTSCH
FRANCAIS
ITALIANO
ESPANOL
CONTENTS
PAGE
GENERAL INFORMATION ...................... 5
CALIBRATION, CERTIFICATION
AND SERVICE ................................ 6
PRESSURE CONVERSION CHART ............... 51
1. INTRODUCTION .............................. 7
2. KEY FUNCTIONS ............................. 8
2.1 ON/OFF Key ........................... 8
2.2 ZERO Key ............................. 8
2.3 SCALE Key ............................ 8
2.4 HOLD Key ............................. 8
2.5 FILTER Key ............................ 8
2.6 RECORD Key .......................... 9
2.7 AUTO Switch Off ........................ 9
3. CONNECTION TO PRESSURE SOURCES ......... 10
4. OTHER FUNCTIONS ........................... 11
4.1 Battery Low ............................ 11
4.2 Over Range Pressure .................... 11
4.3 Over 9999 Reading Indication .............. 11
4.4 Differential or Gauge Measurement .......... 11
4.5 Battery Replacement ..................... 12
4.6 Use with Pressure Test Kit ................. 12
4.7 Silicone Version ......................... 12
DEUTSCH
ALLGEMEINE INFORMATIONEN ................. 13
KALIBRIERUNG, BESCHEINIGUNG
UND SERVICE ................................ 14
1. EINFÜHRUNG ................................ 16
2. TASTENFUNKTIONEN ......................... 17
2.1 Taste EIN/AUS (ON/OFF) ................. 17
2.2 Taste NULL (ZERO) ...................... 17
2.3 Taste MESSGRÖSSE (SCL) ............... 17
2.4 Taste HALTEN (HOLD) ................... 17
2.5 Taste FILTER (FILT) ...................... 18
2.6 Taste AUFZEICHNEN (REC) ............... 18
2.7 AUTOMATISCHES Ausschalten ............ 18
PAGE
3. ANSCHLUSS AN DEN DRUCKGEBER ............ 19
4. WEITERE FUNKTIONEN ........................ 20
4.1 Niedriger Ladezustand der Batterie .......... 20
4.2 Druck außerhalb des Bereichs .............. 20
4.3 Überlaufanzeige (9999) ................... 20
4.4 Differentialdruckmessungen oder
Druckanzeige ........................... 20
4.5 Batterieaustausch ....................... 21
4.6 Verwendung mit der Druckprüf-
Ausrüstung ............................. 21
4.7 Silikon-Ausführung ....................... 22
FRANCAIS
GENERALITES ............................... 23
ETALONNAGE, MISE EN CONFORMITE,
ET ENTRETIEN ............................... 24
1. INTRODUCTION .............................. 26
2. TOUCHES DE FONCTION ...................... 27
2.1 Touche ON/OFF ........................ 27
2.2 Touche ZERO .......................... 27
2.3 Touche SCALE ......................... 27
2.4 Touche HOLD .......................... 27
2.5 Touche FILTER ......................... 28
2.6 Touche RECORD ....................... 28
2.7 Arrêt AUTO ............................ 28
3. RACCORDEMENT A UN RESERVOIR SOUS
PRESSION ................................... 29
4. AUTRES FONCTIONS .......................... 30
4.1 Pile Faible ............................. 30
4.2 Dépassement de Pression ................. 30
4.3 Dépassement de l’indication 9999 ........... 30
4.4 Différentielle ou Mesure Manométrique ....... 30
4.5 Remplacement de la Pile .................. 31
4.6 Utilisation avec le Kit de Test de Pression ..... 31
4.7 Modèle Silicone ......................... 31
PAGE
ITALIANO
INFORMAZIONI GENERALI ..................... 32
TARATURA, CERTIFICAZIONE E
MANUTENZIONE .............................. 33
1. INTRODUZIONE .............................. 34
2. FUNZIONI DEI TASTI ........................... 35
2.1 Tasto ON/OFF .......................... 35
2.2 Tasto ZERO ............................ 35
2.3 Tasto SCALE ........................... 35
2.4 Tasto HOLD ............................ 35
2.5 Tasto FILTER ........................... 36
2.6 Tasto RECORD ......................... 36
2.7 Spegnimento AUTOMATICO ............... 36
3. COLLEGAMENTO CON ALTRE FONTI
DI PRESSIONE ............................... 37
4. ALTRE FUNZIONI ............................. 38
4.1 Esaurimento Batteria ..................... 38
4.2 Pressione fuori Campo ................... 38
4.3 Fuori Campo ........................... 38
4.4 Misurazione con Manometro o Dispositivo
Differenziale ............................ 38
4.5 Sostituzione della Batteria ................. 39
4.6 Utilizzo con Kit de Taratura ................ 39
4.7 Versione Silicone ........................ 39
ESPANOL
INFORMACION GENERAL ...................... 40
CALIBRACION, CERTIFICACION
Y SERVICIO .................................. 41
1. INTRODUCCION .............................. 43
2. FUNCIONES DE LAS TECLAS ................... 44
2.1 Tecla ON/OFF .......................... 44
2.2 Tecla ZERO (CERO) ..................... 44
2.3 Tecla SCALE (ESCALA) .................. 44
2.4 Tecla HOLD (RETENER) .................. 44
2.5 Tecla FILTER (FILTRAR) .................. 45
2.6 Tecla RECORD (REGISTRAR) ............. 45
2.7 AUTO Desconexión ...................... 45
PAGE
3. CONEXION A FUENTES DE PRESION ............ 46
4. OTRAS FUNCIONES ........................... 47
4.1 Batería Descargada ...................... 47
4.2 Presión Fuera de Escala .................. 47
4.3 Señal de Lectura más de 9999 ............. 47
4.4 Medición Diferencial o Efectiva ............. 47
4.5 Sustitución de Pila ....................... 48
4.6 Funcionamiento con el Kit de Pruebas ....... 48
4.7 Versión Silicona ......................... 48
SPECIFICATION .............................. 49
OPERATING INSTRUCTIONS
FOR COMARK C9500 SERIES
PRESSURE METERS
GENERAL INFORMATION
WARNING
INPUT HOSES SHOULD NOT BE DISCONNECTED FROM THE INSTRUMENT WHILST CONTAINING GASES WHICH ARE DANGEROUS AND/OR UNDER PRESSURE.
DO NOT APPLY PRESSURES BEYOND THE OVER RANGE MAXIMUM FOR THE INSTRUMENT OR DAMAGE MAY OCCUR.
REFER TO SECTION 3 — CONNECTION TO PRESSURE SOURCES BEFORE OPERATING THE INSTRUMENT.
This instrument is manufactured in accordance with the Company’s ISO 9001 Quality Approved System.
ISO 9001
FM 26700
This instrument complies with the Electromagnetic Compatibility Directive EN61326-1.
Declarations of Conformity available. Contact Comark Customer Support or your local Distributor.
In line with its policy of continuous development, Comark Instruments
reserves the right to alter the instrument specication without prior
notice. Further information is available from Comark Instruments or your distributor.
CALIBRATION, CERTIFICATION AND SERVICE
Certication
Comark can provide certicates of calibration for its whole product range, to suit
ISO 9000 and other quality assurance procedures, food hygiene regulations,
HACCPs and environmental regulations. Comark certicates are produced by
independent quality controlled processes which compare product performance against agreed National Standards. For peace of mind and best practice Comark
recommend annual certication/recalibration.
Two levels of certication are available for infra-red temperature and non temperature instruments, excluding humidity:- UKAS certicates via an external accredited laboratory and NPL traceable certicates from the Comark calibration
laboratory.
Three levels of certication are available for contact temperature products and
these are detailed here:
a) UKAS Temperature Certication
The Comark UKAS (United Kingdom Accreditation Service) accredited
temperature calibration laboratory is one of the nest in the UK. Comark UKAS certicates can offer the lowest uncertainty of 0.01°C and
provide independent proof of correct calibration using equipment and procedures audited by UKAS inspectors. The equipment used is fully traceable to the National Physical Laboratory.
b) UKAS Humidity Certication
In addition to the Comark temperature laboratory, the humidity laboratory
continues the tradition of high accuracy certication and a wide range
(25% to 90%RH) with uncertainties of 2.8% of reading. This range also includes Dew point measurements.
c) NPL Traceable Certication
Comark NPL certicates are traceable to the National Physical Laboratory and can offer uncertainty as low as 0.3°C.
No. 0451
Conformance
Certicates of conformance can be supplied for new, serviced and recalibrated instruments. These conrm that instruments are within their original manufactured specication.
Service/Repairs
Regular servicing and any required repairs, under warranty or after, are available from the Comark Service Department.
For more information on all Comark certication, calibration and service facilities
please call Comark Customer Support or contact your local distributor.
1. INTRODUCTION
The C9500 series pressure meters includes:-
C9551 Range 0 to ±2 PSI / 0 to ±140mbar Differential
C9553 Range 0 to ±5 PSI / 0 to ±350mbar Differential
C9555 Range 0 to ±30 PSI / 0 to ±2000mbar Differential
C9557 Range 0 to ±100 PSI / 0 to ±6900mbar Differential
2. KEY FUNCTIONS
2.1 ON/OFF Key
Press once to switch on the instrument. Repeat to switch off.
Holding down the key when switching on will display the maximum pressure range of the instrument in PSI.
Holding down the key when switching off will display all segments as a test.
2.2 ZERO Key
Press to zero the current readings on the display to nullify any offsets caused by large temperature variations. The instrument will retain the zero value in memory even after switch off, so that the zero reading will be displayed when the instrument is switched on again. The zero key can be used whenever offsets occur. Please note that pressing the zero key has no effect whilst the instrument is in hold or record modes.
2.3 SCALE Key
Press to display the pressure measurement in each of the different scales available. The selected scale unit is retained in memory even after switch off, so that the selected unit can be displayed when the instrument is switched on again.
2.4 HOLD Key
2.5 FILTER Key
Press to hold the displayed reading and press again to resume measurement. The scale key will operate while the instrument is in hold mode so that the held reading can be displayed in different scales.
Press to lter out transient readings. In lter mode the
instrument will average the readings taken over the last 4 seconds (16 readings) to provide a more stable reading on the display. Press the key again to resume normal measurement.
2.6 RECORD Key
Press once to put the instrument into record mode. This will be indicated by the word RECORD on the display. Maximum and minimum pressure readings can be stored and displayed while the instrument is in record mode. When the instrument is in record mode, press key once to display the current maximum reading and press again to display the current minimum reading. Pressing the key a third time will return the display to normal measurement.
Record mode can be cancelled and the max/min readings cleared by pressing and holding down the key until the word RECORD disappears from the display.
The scale key will operate while the instrument is in record mode so that the max/min readings can be displayed in different scales.
2.7 AUTO Switch Off
The instrument can be programmed to auto switch off by pressing and holding down the HOLD key while using the ON/OFF key to switch on the instrument. The word AUTO appears on the display to indicate auto switch off mode and the instrument will switch itself off approximately 3 minutes after the last use of the keypad. Auto switch off mode can be cancelled by pressing and holding down the HOLD key while switching on manually with the ON/OFF key.
3. CONNECTION TO PRESSURE SOURCES
The C9500 Series instruments are tted with
1
/8" BSP female connectors. The following checks must be made before connecting the instrument to a pressure source:-
Check the security of all ttings.
Check that the pressure source does not exceed the ratings for the instrument as set out in Table 1.
Check that the gases to be measured will not damage or corrode stainless steel, brass, glass, ceramic, silicon, nickel, aluminium, gold or epoxy resin.
Note: Comark C9500 Series Pressure Measurement Instruments are not suitable for absolute pressure measurement.
Note: Pressures in excess of maximum over range
gure with respect to atmospheric pressure, should
not be applied to either port as this could damage the instrument or represent a safety hazard.
TABLE 1
Instrument Pressure Range Maximum Over/ Under Pressure
C9551 0 to ±2 PSI/140mbar 6 PSI/400mbar C9553 0 to ±5 PSI/350mbar 15 PSI/1000mbar C9555 0 to ±30 PSI/2000mbar 90 PSI/6200mbar C9557 0 to ±100 PSI/6900mbar 200 PSI/13700mbar
10
4. OTHER FUNCTIONS
4.1 Battery Low
Low battery is indicated by the symbol BAT on the display. Replace the battery as soon as possible after this symbol appears.
4.2 Over Range Pressure
If the pressure measured (either positive or negative pressure) exceeds the full scale of the instrument, the display will show – – – –
If this occurs the pressure must be reduced to avoid damage to the sensor in the instrument.
4.3 Over 9999 Reading Indication
If the numeric value for display exceeds ±9999, with or without a decimal point, the display will blink and suppress the top (5th) digit, whilst continuing with correct values of the lower 4 digits.
4.4 Differential or Gauge Measurement
C9500 series instruments can be used in either a gauge or differential pressure measurement system.
Gauge:
For positive gauge measurements the negative (-ve) port should be left open to atmospheric pressure and the positive (+ve) port used to input the pressure. For negative gauge measurements the positive (+ve) port should be left open and the ‘vacuum’ applied to the negative (-ve) port. Please note that in this case the reading displayed will be positive even though a vacuum is being measured.
Differential:
When measuring differential pressures, ensure that the most positive (+ve) pressure is applied to the positive (+ve) port.
11
4.5 Battery Replacement
Unscrew the two screws at the base of the instrument and slide off the battery cover. Replace the battery with a 9V PP3 type battery. Replace the battery cover taking care not to over tighten the two screws.
4.6 Use with Pressure Test Kit
The C9500 series instruments can be used together with the optional TK2 pressure test kit as a low cost calibration system for checking or calibrating other pressure instruments.
To use TK2 as a calibrator, connect a calibrated C9500 series instrument, suitable for the maximum pressure to be used, to one of the ports on the hand-pump. Connect the instrument to be checked or calibrated to the other port. Read the instructions supplied with the TK2 kit for details of the pump operation. Ensure the C9500 meter is zeroed with the pressure relief valve open before measurements or adjustments are made.
Note: With the C9551 meter it is possible to over­range the instrument with just one squeeze of the pump handle. If this should occur unscrew the pressure release valve slowly until the display again shows a pressure reading then tighten. The volume adjustment
on the pump may now be used for ne control of the
applied pressure.
4.7 Silicone Version
Although C9500 instruments are generally used for gas/ air measurement, special versions are available with silicone protection to allow liquid pressure measurement without sensor corrosion.
12
BEDIENUNGSANLEITUNG
COMARK C9500
DRUCKMESSGERÄTE
ALLGEMEINE INFORMATIONEN
WARNUNG
DIE ZUFLUSSSCHLÄUCHE SOLLTEN NICHT VOM GERÄT ABGETRENNT WERDEN, WÄHREND SIE GESUND­HEITSSCHÄDIGENDE FLÜSSIGKEITEN BZW. GASE ENTHALTEN ODER SOLANGE SIE UNTER DRUCK STEHEN.
KEINE DEN MAXIMALEN BEREICH DES GERÄTS ÜBERSCHREITENDE DRÜCKE ANLEGEN, SONST KÖNNTEN SCHÄDEN VERURSACHT WERDEN.
SIEHE ABSCHNITT 3 — ANSCHLUSS AN DRUCKGEBER VOR EINSCHALTEN DES GERÄTES.
Die Fertigung des Geräts erfolgt in Übereinstimmung mit den Qualitätssicherungsnachweisforderungen von ISO 9001.
ISO 9001 FM 26700
Das Gerät entspricht den Richtlinien für elektromagnetische Verträglichkeit EN61326-1.
EC Konformitätsbescheinigungen sind erhältlich und anzufordern vom Comark Kundenservice oder vom lokalen Vertriebspartner.
Entsprechend dem Geschäftsgrundsatz einer dauernden Weiterentwicklung behält sich Comark Instruments das Recht vor, die technischen Daten des Geräts ohne vorherige Notiz zu ändern. Weitere Informationen stehen von Comark Instruments oder Ihrem Händler zur Verfügung.
13
KALIBRIERUNG, ZERTIFIZIERUNG UND SERVICE
Zertizierung
Comark kann Kalibrierzertikate für die gesamte Produktpalette bereitstellen,
die für ISO 9000 und andere Qualitätssicherungsverfahren sowie für Lebensmittelhygieneverordnungen, HACCPs und Umweltverordnungen gültig
sind. Zertikate von Comark werden in unabhängigen, qualitätskontrollierten
Verfahren erstellt, die die Produkteigenschaften mit den jeweiligen nationalen Normen vergleichen. Um den sorgenfreien Betrieb sicherzustellen und die
Vorschriften zu beachten, empehlt Comark eine jährliche Zertizierung und
Neukalibrierung.
Zwei Zertikat-Klassen sind für Infrarot-Temperaturmessgeräte und Nicht­Temperaturmessgeräte sowie Feuchtemeggeräte lieferbar: UKAS-Zertikate über ein externes akkreditiertes Labor und NPL rückführbare Zertikate durch das
Comark Kalibrierlabor.
Für Kontakttemperaturmessprodukte gibt es die drei folgenden
Zertizierungsniveaus:
a) UKAS-Zertizierung
Das von UKAS (United Kingdom Accreditation Service) akkreditierte Comark-Temperaturkalibrierungslabor gehört zu den besten in Großbritannien. Comark können UKAS Bescheinigungen die niedrigste
Ungewißheit von 0.01°C anbieten und können unabhängigem Beweis
Gebrauch Geräte richtiger Kalibrierung und Verfahren versorgen, die von UKAS Inspektoren revidiert werden.
b) UKAS Zertikate für rel. Feuchte
Zusätzlich zur Comark-Temperatur ist unser Labor für Feuchtigkeit jetzt
in der Lage Kalibrierzerticake für rel. Feuchte zu erstellen. Die Tradition für Zertikate mit hoher Genauigkeit und einen weiten Messbereich
wird fotgesetzt. Wir kalibrieren Feuchte von 25% bis 90% rF mit einer Abweichung von 2,8% des gelesenen Wertes.
No. 0451
c) Zertizierung nach NPL-Standards
Comark sind NPL Bescheinigungen auffundbar zum Nationalen
Physischen Labor und können Ungewißheit so niedrig wie 0.3°C
anbieten.
Konformität
Konformitätszertikate können für neue, gewartete und neu kalibrierte Instrumente vorgelegt werden. Diese Zertikate bestätigen, dass die Geräte ihren ursprünglichen Herstellerspezikationen entsprechen.
14
Service/Reparaturen
Die Kundendienstabteilung von Comark bietet regelmäßige Wartung und alle erforderlichen Reparaturen, auch nach Ablauf der Garantiezeit.
Weitere Informationen über alle Comark-Zertizierungen, Kalibrierungen und
Kundendiensteinrichtungen erhalten Sie entweder bei Comark direkt oder bei Ihrem Händler.
15
1. EINFÜHRUNG
Die Baureihe C9500 umfaßt vier Druckmeßgeräte:
C9551 Bereich 0 bis ±2 PSI/0 bis ±140mbar Differenzmessung
C9553 Bereich 0 bis ±5 PSI/0 bis ±350mbar Differenzmessung
C9555 Bereich 0 bis ±30 PSI/0 bis ±2000mbar Differenzmes­sung
C9557 Bereich 0 bis ±100 PSI/0 bis ±6900mbar Differenzmes­sung
16
Loading...
+ 37 hidden pages