ONLY QUALIFIED PERSONNEL SHOULD INSTALL THESE UNITS. THE INSTALLATION
SHOULD CONFORM TO ALL LOCAL CODES. IN SOME COUNTRIES, A CERTIFIED ELECTRICIAN MAY BE REQUIRED.
CODE BLUE CORPORATION PROVIDES NO WARRANTY WITH REGARD TO THIS GUIDE, THE
SOFTWARE OR OTHER INFORMATION CONTAINED HEREIN AND HEREBY EXPRESSLY DISCLAIMS ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE WITH REGARD TO THIS GUIDE, THE SOFTWARE OR SUCH OTHER INFORMATION. IN NO EVENT SHALL CODE BLUE CORPORATION BE LIABLE FOR ANY INCIDENTAL,
CONSEQUENTIAL, OR SPECIAL DAMAGES, WHETHER BASED ON TORT, CONTRACT, OR
OTHERWISE, ARISING OUT OF OR IN CONNECTIONS WITH THIS GUIDE, THE SOFTWARE
OR OTHER INFORMATION CONTAINED HEREIN OR THE USE THEREOF.
Code Blue Corporation reserves the right to make any modications to this guide or the information
contained herein at any time without notice. The software described herein may also be governed
by the terms of a separate user license agreement.
Code Blue® is a registered trademark of Code Blue Corporation.
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
GU-159-Dpage 3 of 38
Page 4
CB 9 Series
Administrator Guide
2 Introduction
Thank you for choosing the CB 9 Series for your Code Blue application.
The CB 9 Series is a versatile freestanding pedestal that is intended for gated entries where cars
and semi-trucks require access and communication. Available in a variety of congurations, it allows
for the installation of additional safety products, including cameras, card readers or other security
devices. The CB 9 Series can withstand a high rate of abuse and is ideal for parking entry points
and other gatekeeper applications.
The exclusive analog InterAct and VoIP speakerphones are designed for maximum reliability, vandal
resistance, auxiliary functions, mass notication control, and fault monitoring and reporting capability
(see IA4100 or IP5000 guides for more information).
Our unmistakable craftsmanship makes our Help Points® the most rugged on the market,
withstanding the punishment of natural and man-made disasters. With durable construction, our
pedestal units can meet any requirement or purpose. CB 9 Series units have a rugged steel
construction, industrial engineering grade reective graphics and weather, UV and grafti resistant
paint.
Other options include:
• IP and analog phones
• Low power consumption LED faceplate light
• Car and truck heights
• NightCharge®
• PoE power
• Custom colors and graphics
• Remote Mount LED Beacon/Strobe Kit
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
GU-159-Dpage 4 of 38
Page 5
CB 9 Series
Administrator Guide
This guide contains all of the CB 9 Series information for the CB 9-s, CB 9-d, and the CB 9-t. This
guide contains a general overview of the CB 9 Series options and its application, installation and
wiring.
CB 9-sCB 9-t
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
CB 9-d
CB 9-t
Single
CB 9-t
Single Single
CB 9-t
Single Dual
CB 9-t
Dual
CB 9-t
Dual Single
Dual Dual
GU-159-Dpage 5 of 38
Page 6
CB 9 Series
Administrator Guide
3 Getting Started
Basic Install Instructions
1. EIA/TIA, ANSI, CSA and BICSI cabling or similar standards shall be adhered to for proper
operation of Code Blue communication devices connected to copper or ber infrastructures. Communications cable and electrical cable in the same conduit is not an acceptable instal lation and shall not be supported. Analog phones require a minimum of 23mA for proper
operation (26-29mA recommended).
2. Each analog speakerphone requires its own phone line or PBX extension. Multiple units
shall not be supported.
3. Speakerphones require programming before operation. Consult the User Guide or Admin istrator Guide enclosed with the unit or visit www.codeblue.com > Support > Downloads to
read or download manuals.
4. If you are installing IP speakerphones, please read the appropriate manuals and consult
with your Network Administrator.
5. Size electrical wiring based on length of run.
6. Consult the enclosed document packet for internal wiring instructions.
1Enclosure - CB 9-s, CB 9-d, CB 9-t Single, CB 9-t Single Single, CB 9-t Single Dual,
CB 9-t Dual, CB 9-t Dual Single, CB 9-t Dual Dual
2Access Door Screws
1URL listing sheet of Installation, Programming, Wiring & Warranty locations
CB 9 Series Tools Required
1. Ladder to reach the top of the dual units
2. Drill and security bit for removing and inserting security screws on phone, dome top and
access door
3. 11/8 socket set and extension for installing anchor bolts or Deck Mount Kits
4. Phillips head screwdriver and at head screwdriver
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
GU-159-Dpage 6 of 38
Page 7
4 Spare Parts
CB 9 Series
PartPart Number
LED Faceplate Light40196
Faceplate Screws41544 (6pk)
Access Door Screws41545 (2pk)
Manifold R/B 5-way40101
Analog Surge Suppressor41471
IP Surge Suppressor41421
Blank Lexan Plate Assembly40067
CB 9 Series Additional Options
PartPart Number
CB 9 Series
Administrator Guide
Multi Tap Transformer (powers accessories) 120V, 240V, 277V, 347V40104
Blank Lexan Plate Assembly40067
Service Plate - Lexan w/graphics (This Location Being Serviced) 40208
Deck Mount Kit40215
Triad Transformer 40V A 120V
S-1000 or S-1050 LED Remote Beacon/Strobe Kit40542
PoE Power Splitter Kit Assembly41574
IP5000 Speakerphone FP150101
IP5000 Speakerphone FP250102
IP5000 Speakerphone FP350103
IP Color Camera Assembly41420
Directory Plate Assembly40057
Custom Cutout Stainless Steel PlatesDrawing needed for part#
PAS WM-180 Color Needed for part#
(will not power accessories)41246
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
GU-159-Dpage 7 of 38
Page 8
CB 9 Series
Administrator Guide
5 Power Requirements
(The following power requirements include the 9 Series and also ALL OTHER Code Blue units.)
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
GU-159-Dpage 8 of 38
Page 9
CB 9 Series
Administrator Guide
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
GU-159-Dpage 9 of 38
Page 10
CB 9 Series
Administrator Guide
6 Software Configuration
Blue Alert® MNS Software
Blue Alert MNS (Mass Notication Software) lls a need in the marketplace for an incident response
solution that is both comprehensive and cost-effective, while also providing an efcient way to detect
and respond. The advanced mass notication system allows responders to deliver multi-layered
emergency notications via a wide range of platforms, including email, text message (SMS), emer-
gency phones, public address speakers, social media, desktop alerts and more, quickly informing
and directing people in emergency situations.
Blue Alert® EMS
Blue Alert EMS is an advanced software solution that handles all incoming events effectively by remotely controlling emergency communication devices with an easy-to-use Graphical User Interface
(GUI). You also will have the ability to open gates and AED access doors, turn LED beacon/strobes
on or off, transfer calls to Public Address Systems to make area wide announcements and incorporate other ancillary devices and applications while the system securely archives data for future
reference.
ToolVox®
A sophisticated emergency management platform for your blue light phone network, ToolVox offers
unique real-time monitoring and provisioning options for emergency phones and public address
speakers, effectively acting as a hub for connecting Help Points® and other Code Blue devices. Using our proprietary incident response software, Blue Alert® MNS and EMS, you can send alerts via
outdoor platforms, such as blue light phones and public address speakers. It also provides connections to PBX, public telephone (PSTN) and Internet (ISP) networks, in addition to third party security
platforms.
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
GU-159-Dpage 10 of 38
Page 11
7 CB 9-s Low Voltage Exploded View
5
6
7
CB 9 Series
Administrator Guide
8
BALL #PART #DESCRIPTION
1CALLStandard / Custom Graphic
241471Analog Surge Suppressor
241421IP Surge Suppressor
340101Manifold R/B 5-way
441545Access Door Screws (2 pk)
541548LED Faceplate Light
650001Single Button IA4100 Analog Phone – PUSH FOR HELP
650002Double Button IA4100 Analog Phone – PUSH FOR HELP
650003Keypad IA4100 Analog Phone – PUSH FOR HELP
650004Single Button IA4100 Analog Phone – EMERGENCY
650005Double Button IA4100 Analog Phone – EMERGENCY
650006Keypad IA4100 Analog Phone – EMERGENCY
650007Single Button IA4100 Analog Phone – EMERGENCY/EMERGENCIA
650008Double Button IA4100 Analog Phone – EMERGENCY/EMERGENCIA
650009Keypad IA4100 Analog Phone – EMERGENCY/EMERGENCIA
Note: Please contact Code Blue Customer Service if a custom cutout is needed on the CB 9-d for
third party products, such as a card reader or a custom camera to mount on the second opening
plate.
Contact Code Blue Customer Service at 800-205-7186 or customerservice@codeblue.com.
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
GU-159-Dpage 15 of 38
Page 16
12 CB 9 Series Installation Instructions
1.0 FOUNDATION – (see Anchor Bolt Installation Instructions)
2.0 SET THE UNIT
2.1 Screw one set of nuts and washers onto the anchor bolts – After the foundation has
set, screw one set of nuts followed by one set of washers onto the anchor bolts. Set the
nuts such that the lowest washer is about 2½ inches above the concrete and at an even
height. To accomplish this, use a small level and check all three directions. These nuts
are not adjustable after the unit is in place. The bottom edge of the Code Blue unit will be
½-inch above the concrete when installed.
IMPORTANT: The leveling of the bottom nuts is crucial to the leveling of the unit. A small
error in the adjustment of these will be magnied after installation.
IMPORTANT: A ½-inch air gap is required between the foundation and the unit. Moisture
problems may result if this condition is not complied with.
CB 9 Series
Administrator Guide
2.2 Set the unit on the anchor bolts – Align the phone plate in the desired direction and lift
2.3 Secure the unit – Access the mounting studs through the door on the side of the unit.
3.0 WIRING
3.1 Ground – The ground (green) wire should be stripped and fastened to the supplied ground-
3.2 24V AC supply – Using the proper crimping tool, attach a #8 fork to each of the incoming
3.3 120/240V AC supply – Using the proper crimping tool, attach a #8 fork to each of the in-
the Code Blue unit over the anchor bolts. Note that the unit weighs 190-420 pounds. Use
appropriate lifting materials and methods to avoid possible injury and/or damage.
Place the second washer and nut and then tighten the mounting nuts onto the anchor
bolts. This may be more convenient if a long socket, extension and universal joint is used
to tighten the hardware.
ing lug.
power wires and fasten them to the terminal screws labeled “Line” and “Neutral.”
coming power wires and fasten them to the correct terminals as labeled on the transformer.
After completing the wire connections, install the supplied terminal covers.
All wiring must be installed and connected by experienced and certied personnel to meet
local and national electrical codes, and will include a service disconnect.
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
See diagrams next page
GU-159-Dpage 16 of 38
Page 17
CB 9 Series
Administrator Guide
Figure 1
All wiring must be installed and connected by experienced and certied personnel to meet
local and national electrical codes, and will include a service disconnect.
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
GU-159-Dpage 17 of 38
Page 18
CB 9 Series
Administrator Guide
13 CB 9 Series Tower Base Gasket Installation Instructions
1.0 FOUNDATION (see anchor bolt installation instructions)
2.0 SET THE UNIT
2.1 Screw one set of nuts and washers onto the anchor bolts. After the foundation
has set, screw one set of nuts, followed by one set of washers, onto the anchor
bolts. Set the nuts so the lowest washer is about 2½ inches above the concrete
at an even height.
To accomplish this, use a small level and check from front to back, side to side
and diagonally. These nuts are NOT adjustable after the unit is in place.
The bottom edge of the Code Blue unit will be ½-inch above the concrete when
installed.
2.2 Set the Code Blue unit on the anchor bolts. Align the phone plate in the
desired direction and lift the Code Blue unit over the anchor bolts. The unit may be lifted using the bracket on the inside of the unit. Note that the unit
weighs approximately 200-400 pounds and that the 9 Series does not contain a
bracket on the inside of the unit. Use appropriate lifting materials and
methods to avoid possible injury and/or damage.
IMPORTANT: Leveling the bottom nuts is
crucial to leveling the unit. A small error will be
magnied after installation.
IMPORTANT: A ½-inch minimum air gap is
required between the foundation and the unit to
prevent moisture problems.
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
GU-159-Dpage 18 of 38
Page 19
CB 9 Series
Administrator Guide
3.0 Install the Base Gasket
3.1 Access the mounting studs through the access door on the side of the unit.
3.2 Set the gasket on the bolts and cut a small hole where the conduit is located.
Stretch the screen tightly around the conduit pipe. Slide the gasket over the bolts to the
base of unit.
3.3 Place the second washer on the anchor bolt and place the nut on top.
Tighten the mounting nuts onto the anchor bolts. This may be more convenient
if a long socket, extension and universal joint is used to tighten the hardware.
*For an extra-strong seal, a bead of silicone caulk can be put on the
gasket from bolt hole to bolt hole before setting the gasket into place and
around the conduit.
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
GU-159-Dpage 19 of 38
Page 20
CB 9 Series
Administrator Guide
14 CB 9 Optional WM-180 Installation Instructions
Note: If WM-180 unit does not include an IP or Analog controller board, then it must be located near
an IA4100 or IP5000 speakerphone for the 20’ supplied PAS cables to reach it.
See included drawing for anchor bolt and conduit locations.
WITH CONTROLLER BOARD
Supply 24V AC to Power Manifold.
Supply Phone line to Phone Port if analog controller board, or Ethernet IP Connection to LAN port if
IP Controller board.
Reference IA4100 Admin and User Guide for programming of analog controller board.
Reference IP5000 Admin and User Guide for programming of IP controller board.
Code Blue Guides are located at www.codeblue.com > support > downloads.
WITHOUT CONTROLLER BOARD
Supply 24V AC to Power Manifold
See attached Wiring Diagram for connecting, PAS Audio Cable and the PAS Control Cable, to the
nearby IA4100 or IP5000 speakerphone.
Reference IA4100 Admin and User Guide for programming of analog controller board.
Reference IP5000 Admin and User Guide for programming of IP controller board.
Code Blue Guides are located at www.codeblue.com > support > downloads.
See diagrams next page
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
GU-159-Dpage 20 of 38
Page 21
CB 9 Series
-/
-
Administrator Guide
Product wiring diagram shown reasonably represents current offering and is intended to assist in component identication and service. Earlier product production may have different
components and wiring connections. Reference the model and serial number from the unit ID tag and contact manufacturer to conrm replacement part version and availability.
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
GU-159-Dpage 21 of 38
Page 22
CB 9 Series
Administrator Guide
20.10
15.00
3.50
15.12
10.40
2.50
8.50
4.05
7.50
10.00
1.13
CONDUIT HOLE
BACK VIEW
.44
MTG HOLES
2.05
Specications subject to change without notice or obligation
on the part of the manufacturer.
.75
2.5010.00
BOTTOM VIEW
1.13
CONDUIT HOLE
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
GU-159-Dpage 22 of 38
Page 23
CB 9 Series
Administrator Guide
15 CB 9 Series Anchor Bolt Installation Instructions
1.0FOUNDATION
1.1 Conduit – Electrical and telephone line conduit, with a maximum combined diameter of
four inches, should be run up through the center of the foundation hole. A minimum of four
inches and a maximum of six inches of conduit above the nished grade level is required. To
ensure proper grounding, a ½-inch x 8-foot copper rod should be inserted in the center of the
foundation and tied to the steel bollard.
NOTE: Follow all national and local codes governing this installation.
1.2 Pour the Foundation – The foundation should be at least 24 inches in diameter and to the
correct depth for the frost line in your area, with a minimum depth of at least three feet (follow
local building codes for foundations).
1.3 Set the Anchor Bolts in the Wet Foundation – Four 24-inch L-shaped anchor bolts and an
aligning template are supplied for anchoring the Code Blue unit. The bolts should be set into
the foundation so that six inches are left showing above the nished grade level. The anchor
bolts should be aligned, using the supplied template in such a way that the phone faceplate
on the unit will face in the desired direction.
2.0WIRING
2.1 Pull power and phone line up through the conduits – A minimum of two feet of wire must be
available from the conduit for electrical and communications wiring.
KEEP CONDUIT
CONTAINED WITHIN
4.00" DIAMETER
24.00
4.00
PHONE FACEPLATE DIRECTION
FOR ANCHOR BOLTS
4.00
8.00
BOLT CIRCLE
6.00
TO BE DETERMINED
BY FROST LINE AND
LOCAL CODES
USE PROVIDED TEMPLATE TO LOCATE ANCHOR BOLTS
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
GU-159-Dpage 23 of 38
Page 24
CB 9 Series
Administrator Guide
16 CB 9 Overhead Camera Mount Installation Instructions
TOOLS REQUIRED
Access Panel
Security Bit
INSTALLING THE OVERHEAD CAMERA MOUNT
The camera mount will come with a gasket already mounted to the bracket on the arm. Place the bracket over
the mounting holes and insert the four 3/8-16 X 1 stainless bolts. (The 3/8” stainless steel bolts should have
one stainless steel washer and one rubber washer.) Verify the camera mount is evenly positioned to ensure
the gasket seal is properly seated. Tighten the bolts with your 3/8” wrench in a crisscross pattern to ensure
even pressure until it is snug against the outside of the bollard.
INSTALLING THE CAMERA
Camera and wiring (supplied by others) is installed into the male 1½ NPT.
NOTE: If you are retrotting an existing unit, the Overhead Camera Mount must be set in the desired position on
the side of the bollard with the four holes marked for drilling and tapping. Once the holes are marked, they will
need to be drilled and tapped to receive the 3/8” course thread stainless steel bolts. A 2” hole will need to be
drilled out of the center of the four holes for the camera wiring. (Mount bracket on the opposite side of the phone
opening, lining up with the center of the phone opening.)
3/8Wrench
Ladder
DRILL ONE
2” DIA HOLE
FOR WIRING
IN LINE WITH PIPE
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
GU-159-Dpage 24 of 38
Page 25
CB 9-T WITH OVERHEAD CAMERA MOUNT
CB 9 Series
Administrator Guide
6.23
Please contact Customer Service with any questions or concerns.
Email: customerservice@codeblue.com
Phone: 616-392-8296, Opt. 2
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
NOTE: Instructions pertain to
Model S-1000 LED Beacon/Strobe and
Model S-1050 LED Beacon/Strobe only
M3159-R/BK
M3159-Y/Y
DRY CONTACT
CLOSED = "ON"
RED
BLACK
YELLOW(FLASH MODE)
YELLOW(FLASH MODE)
POSITIVE (12-24V DC or AC)
COMMON (GROUND)
CAUTION: REMOVE ALL POWER FROM UNIT BEFORE SERVICING.
ATTENTION: WHEN REPLACING A BEACON/STROBE ON THE MODEL CB 5
SERIES ONLY, MOUNTING SCREW THREADS MUST BE COATED TO PREVENT
WATER LEAKAGE INTO THE UNIT.
OPERATION
To activate the LEDs in the PRIMARY-STEADYBURN MODE, connect the BLACK and RED
wires to 12-24 volts AC or DC.
When in PRIMARY-STEADYBURN MODE, to change the LEDs to SECONDARY-FLASH MODE,
connect both YELLOW control wires together (i.e., CLOSED = ON).
PHOTOCELL FEATURE (S-1050 MODEL)
The Steadyburn Mode will be ON in dark or night ambient environments and OFF in bright or
daylight ambient environments. The S-1050 LED Beacon/Strobe has two built-in photo response
features: (a) dawn/dusk transition delay of 15-30 minutes and (b) transient light acknowledgement
delay of at least 3 minutes.
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
GU-159-Dpage 26 of 38
Page 27
CB 9 Series
Administrator Guide
PROGRAMMING PRIMARY & SECONDARY MODES
1. Remove power from unit.
2. Short the Yellow wires together.
3. Restore power to the unit and wait until the unit begins to ash. Once the unit begins to ash,
remove the short. The unit will alternately demonstrate the Secondary-Flash Mode and PrimarySteadyburn Mode that will be displayed during operation. For approximately 4 seconds the
Secondary-Flash Mode will be demonstrated, followed by the Primary-Steadyburn Mode.
4. To select the next mode of operation, momentarily short the yellow wires. The unit will cycle to
the next mode in the list above.
5. There are seven Flash Modes and three Steadyburn Modes combinations to choose from.
6. When you reach the desired mode of operation, remove power from the unit. You MUST leave
power disconnected for 20 seconds BEFORE reapplying. When power is reapplied, the unit will
operate as programmed above.
NOTE: If you do not leave power disconnected for 20 seconds before reapplying power, the light
will default to Program Mode.
INPUT VOLTAGE RANGE: 12-24V AC or DC
0
TEMPERATURE RATING: -40
TYPICAL POWER CONSUMPTION AT 25
Voltage Flash ModeSteady Mode - High
12V DC0.24 A Max0.24 A
24V DC0.12 A Max0.12 A
12V AC1.1 A rms Max0.53 A rms
24V AC0.22 A rms Max0.22 A rms
NOTE: Average current draw in Flash Mode will vary by selected Flash Mode. The above maximum amperage draw is
stated at Single 60 FPM.
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
C to +650 C (-400 F to 1490 F)
0
C
GU-159-Dpage 27 of 38
Page 28
CB 9 Series
Administrator Guide
18 Remote Mount Beacon/Strobe Installation Instructions
1.0 ATTACH J-BOX TO THE POLE
1.1 Thread the banding (B) through the pole bracket (A) located on the backside of the J-box (C).
1.2 Wrap the banding around the pole. Cut the banding to desired length.
1.3 Using a screwdriver or nut driver, tighten the banding and make sure that the unit is in the desired
location.
NOTE: J-box must be positioned so weep hole faces down.
2.0 ATTACH LIGHT TO BRACKET
3.1 Using the three M4 X 8 screws enclosed (K), fasten the strobe (J) to the round portion of the
strobe bracket.
NOTE: If the beacon/strobe is mounted upside-down, a drain hole must be drilled into the lens
to prevent it from lling with water.
3.0 ATTACH LIGHT AND BRACKET TO THE J-BOX
4.1 Connect all wiring from the strobe to the wiring from the unit inside of the J-box using wire nuts.
4.2 Attach strobe bracket to the J-box using four 6-32 X ½ screws as shown.
A - pole-bracket
B - banding
C - J-box
D - pole-bracket mount nut (4 each)
E - pole-bracket mount screw (4 each)
F - conduit plug
H - strobe-bracket
I - 6-32 X ½ screws (4 each)
J - strobe light
K - M4 X 8 screws (3 each) (Low voltage)
K - 10-24 X ¾ screws (2 each) (High voltage)
All wiring must be installed and connected by experienced and certied personnel to meet local and national electrical codes, and will
include a service disconnect.
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
GU-159-Dpage 28 of 38
Page 29
2
802.3af / at Switch
LAN 2
LAN 1
WAN
PoE
PAS
Control
Aux ports
PAS
Audio
+ -+ -
Power | Battery
S-550
S1000
Ethernet
1
IP5000 Connector Side
Grounding:
Should a ground be needed,
there’s a ground screw on the
enclosure with grounding logo
next to it.
When the splitter is mounted to
the mounting bracket the bracket
becomes the ground to the
chassis of the enclosure,
however local codes may require
a ground wire be attached to the
screw in order to comply.
4
3
Data +PoE
DATA
1b
LED Faceplate Light Bar
12VDC
PoE
CB14591 PoE Splitter
2.6
2.1
1.3
1
First, Electrical connection: All 3
Code Blue device’s should to be
connected to the 5 place manifold
Special Note: Notice the power cable is
connected to the Battery / Alternative Power
port of the IP5000. – See Item 1b
2
Second: Manifolds fused red lead
and black wires are secured to
spring cage connector on the
CB14591. SEE DIAGRAM
Third Step: Connect the DATA
cable RJ-45 from the Splitter
“DATA” to the IP5000 WAN PoE
port.
3
4
Fourth Step: Plug in the Ethernet
PoE Cat 5e Cable to Data+PoE
Input jack on the Splitters.
Upon PoE Negotiation with the
PoE switch port, power will be
granted to the Splitter, and the
indicator along with the device
attached will turn on.
Item
InRush
(i)
InRush
Wattage
Norm (i)
802.3af
Wattage
802.3at
Wattage
IP50000.222.640.091.081.08
FP LED0.080.960.040.480.48
Combo LED0.33 .60.263.123.12
Total s0.67.200.394.684.68
CAT5e
< 3ft
in out
GRD
3ft
Cat5e
Cust
Cat5e
19 PoE Installation Instructions
CB 9 Series
Administrator Guide
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
GU-159-Dpage 29 of 38
Page 30
CB 9 Series
Administrator Guide
20 CB 9 Series Deck Mount Installation Instructions
1.0 DECK MOUNT FOUNDATION
1.1 Drill Deck Holes – Drill four holes through the deck or oor for the four 3/4” threaded rods.
The holes should be aligned, using the template provided in such a way that the phone face-
plate on the unit will face in the desired direction (see gure below).
1.2 Drill a fth hole in the center to accommodate the conduit.
1.3 Position Upper Deck Plate – Position the rst plate working from above the deck.
1.3.1 Thread a nut and washer on the end of each rod so that approximately six inches extends beyond the base of the washer.
1.3.2 Insert each rod through the top side of the plate, plate gasket, and down through the
four holes in the deck.
NOTE: The top of the plate is the side with the tapered edge.
1.4 Position Lower Deck Plate – Position the second plate working from below the deck. Have
another worker hold the upper plate and rods in place from above the deck.
1.4.1 Place the second plate gasket and then the second plate over the threaded rods.
1.4.2 Secure the second plate with nuts and washers provided. If required, readjust the nuts
so that six inches of the rods are above the top of the upper plate (see gure below).
1.5 Secure Lower Nuts – To prevent tampering, it is advisable to tack weld the lower nuts to the
threaded rod.
2.0 WIRING
2.1 Pull power and phone line through conduits – A minimum of two feet of wire must be available from the conduit for electrical and communications wiring.
2.2 Conduit – Electrical and telephone line conduit is run through the deck and the center openings (two-inch diameter) of the upper and lower deck plates. A minimum of four inches and a
maximum of six inches of conduit above the upper plate is required.
Ø14.00
DECK PLATE
Ø8.00
BOLT CIRCLE
CB 1 Base
ALLOW
1/2" GAP FOR
VENTING
ELECTRICAL
AND TELEPHONE
LINE CONDUIT
6.00
3/4" THREADED ROD OF SUFFICENT
LENGTH TO PASS THROUGH DECK
AND ALLOW A MINIMUM OF 6”
ABOVE THE TOP DECK PLATE.
PHONE
FACEPLATE
DIRECTION
BB
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
GU-159-Dpage 30 of 38
Page 31
Administrator Guide
21 CB 9 Series Standard Wiring (prior to 03/2013)
(with Hammond Transformer)
CB 9 Series
Product wiring diagram shown reasonably represents current offering and is intended to assist in component identication and service. Earlier product
production may have different components and wiring connections. Reference the model and serial number from the unit ID tag and contact
manufacturer to conrm replacement part version and availability.
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
GU-159-Dpage 31 of 38
Page 32
-
-
/
22 CB 9 Series Standard Wiring
(with Multi-tap Power Brick)
CB 9 Series
Administrator Guide
Product wiring diagram shown reasonably represents current offering and is intended to assist in component identication and service. Earlier product
production may have different components and wiring connections. Reference the model and serial number from the unit ID tag and contact
manufacturer to conrm replacement part version and availability.
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
GU-159-Dpage 32 of 38
Page 33
23 Multi Tap Transformer Wiring
Power
Incoming
Supplier
from
Primary Side of the
Transformer
CB 9 Series
Administrator Guide
y
Secondar
Transformer
Side of the
Source L1 (White)
Source L2 (Black)
Source L1 (White)
Neutral
120
Capped
Capped
T
Multi-Taransformer Primary
p
Hot
White
Yellow
Black
Brown
Gray
Blue
White
Primary Volt Amps 250
y
Secondarolt Amps 160
ETL – UL ______________
V
24 VAC
C
to
24 VA2V DC
1
Converter
Joined
Hot
Source
Source
Source
Only connect one HOir
point matchin
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
Hot
Hot
L2
L2
L2
240
277
347
T w
g
y
ou
r
s
e to t
ource voltage.
Black
Yellow
Brown
Gray
Blue
he
voltage
12VDC
12VDC
Low Voltage Outputs
5 AmpsA C
5 AmpsD C
24VAC
2a mp fuse
12VDC
2a mp fuse
GU-159-Dpage 33 of 38
Page 34
24 Maintenance Schedule
LEGEND
CB 9 Series
Administrator Guide
Guard tasks
GT
DAILY OR WEEKLY
G
MONTHLY OR QUARTERLY
G
G
T
Perform functional communications check
Action: Press red button
Strobe activates
Red LED “Call Placed” light turns on
Message plays
Call connects, green LED “Call Received” light turns on
Conrm conversation clarity with dispatch
Visually check lighting functions:
Faceplate light Beacon Strobe
Visually inspect unit for damage to:
Faceplate
Piezo button
Microphone (pest infestation, damage or obstructions)
Speaker (pest infestation, damage or obstructions)
Check batteries
Functioning with full charge
Recharging fully, including NightCharge
Technician tasks
®
/Solar units (NOTE: recommend mid- to late afternoon inspection)
BIANNUALLY
T
G
G
T
T
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
Remove access door and faceplate assembly to inspect the following:
Ensure all electrical connections are secure
Check all phone connections for corrosion (If corroded, clean and coat with dielectric gel or replace)
Ensure all battery connections are tight and clean
Verify no stains exist around gasket areas (Stains indicate leaking and gasket should be replaced)
Verify moisture weep hole on cabinet bottom is open and unobstructed
Verify bottom of bollards are at least 1/2 inch above footing and free of obstructions (Only applies to CB 1, CB
5 and CB 9 units)
Apply automotive paint sealant to unit exterior for protecting nish against environmental pollutants (Suggested
products include Black Magic Wet Shine Liquid Wax, Nu Finish NFP-80, and 5 Star Shine )
Clean and coat exterior stainless steel cabinets with cleaner/polish (Suggested products include Chase Products'
Champion Sprayon Stainless Steel Cleaner to help protect nish against environmental pollutants)
Visually conrm line-of-sight is still clear to base station (i.e., conrm that new tree growth, new building construction
or other obstructions are not blocking view of base station)
ANNUALLY
Replace batteries used with NightCharge
communication manufacturer to ensure optimal performance)
®
, cellular or RF systems (Replace with batteries recommended by the
GU-159-Dpage 34 of 38
Page 35
CB 9 Series
Administrator Guide
UNIT SURFACE MAINTENANCE
The painted and stainless steel Code Blue models require periodic care to sustain their aesthetic appearance. Units located
outdoors are vulnerable to harsh environmental conditions, including UV rays, acid rain, diesel fumes and airborn iron particles
(i.e., dust) which over time may cause unit discoloring. To prevent pollutants developing harmful chemical reactions on Code
Blue units, an appropriate surface maintenance schedule should be adhered to. The Surface Care Frequency table below
provides general guidelines to assist in conguring a schedule. Please note that the frequency of care required to guard the
Code Blue unit’s surface from damage will also be dictated by local environmental characteristics.
LEGEND: POLLUTANTS LEVEL
Low
Low/Moderate
Moderate
Moderate/High
High
SURFACE CARE FREQUENCY
Painted
Stainless Steel
See scheduled tasks under Biannually for suggested paint sealants or stainless steel cleaners.
ê
êê
êêê
êêêê
ккккк
MONTHLYBIMONTHLY QUARTERLYBIANNUALANNUAL
кккккêêêêêêêê
кккккêêêêêêêê
AVERAGE COMPONENT LIFE
Component life is based on various mechanical, operational and environmental factors. Your local Code Blue dealer can
assist you with a regularly scheduled maintenance program customized to your individual site requirements.
Code Blue strongly recommends contacting a local CB dealer to establish a proactive maintenance schedule.
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
GU-159-Dpage 35 of 38
Page 36
CB 9 Series
Administrator Guide
25 Locating Unit Serial Numbers
Remove the access plate cover with the special security bit. The serial number will be listed on the
manufacturer’s label located on the backside of the access plate cover (1).
1
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
GU-159-Dpage 36 of 38
Page 37
CB 9 Series
Administrator Guide
26 Warranty
Code Blue Corporation provides a limited warranty on this product. Refer to your sales agreement
to establish the terms. In addition, Code Blue’s standard warranty language, as well as information
regarding support for this product while under warranty, is available at
www.codeblue.com/support/downloads.
In Case of Breakdown
In case of system breakdown, discontinue use and contact :
Tech Support at tss@codeblue.com or call 800-205-7186, option 3.
In Case of Abnormal Operation
If the unit emits smoke or an unusual smell, if water or other foreign material enters the enclosure,
or if you drop the unit or damage the enclosure, power off the unit immediately and contact:
Code Blue Customer Service at customerservice@codeblue.com or call Customer Service at
800-205-7186, option 2.
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
GU-159-Dpage 37 of 38
Page 38
CB 9 Series
Download Information
Administrator Guide
27 Download Information
Main Location: www.codeblue.com/support/downloads
Code Blue now has a centralized location where you can find Installation, Setup, Information,
Configuration & Operation instructions.
1. CB 1 Series Administrator Guide: www.codeblue.com/resources/guides
2. CB 2 Series Administrator Guide: www.codeblue.com/resources/guides
3. CB 4 Series Administrator Guide: www.codeblue.com/resources/guides
4. CB 5 Series Administrator Guide: www.codeblue.com/resources/guides
5. CB 6 Series Administrator Guide: www.codeblue.com/resources/guides
6. CB 9 Series Administrator Guide: www.codeblue.com/resources/guides
These Guides should contain all the information needed for your application. If further information is
needed, please contact customerservice@codeblue.com.
Code Blue • 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
GU-159-Dpage 38 of 38