Code 3 CPS220 User Manual

INSTALLATION & OPERATION
MANUAL
CPS220
REMOTE STROBE
POWER
REMOTE STROBE POWER SUPPLY
IMPORTANT:
CPS220
20W, 2 HEAD
Read all instructions and warnings before installing and using.
INSTALLER: This manual must be delivered to the end user of this equipment.
Introduction
The CPS220 Series Remote Strobe Power Supply represents the latest in state-of-the-art strobe warning technology. The latest in MOSFET technology and advanced design provide efficient operation, meaning superior performance, reliability and long life. The use of intelligent microprocessor control allows the Model CPS220 series to offer more light pattern options and versatility than any other remote system available. The user may select Quad, Triple, Double, Single, Active Flash or Variable Flash, Double-Double and Triple-Triple Patterns. When connected to remote strobe heads, the CPS220 delivers the highest available level of emergency warning signals.
Standard Features
The CPS220 Remote Strobe Power Supply is available as a 2 strobe Hide-a-way kit as part number 220HCL. The 220HCL comes complete with a CPS220 power supply, two Hide-a-way strobe tubes and two 30' cables. Refer to CODE 3 manual T07715 for details on installation of the Hide-a-way strobe tubes. All MODEL CPS220 Remote Strobe Power Supplies have the the following features:
12 AND 24 VDC OPERATION
REVERSE POLARITY PROTECTED
OUTPUT SHORT CIRCUIT/FLASHTUBE FAILURE PROTECTION
Power supply will shut down when trying to flash any heads that have been shorted.
MULTIPLE USER SELECTABLE FLASH PATTERNS
See Flash Control Options Section, page 6.
Note: A user supplied fuse (5A for 12VDC operation, 3A for 24V operation) must be installed in series with the red wire. Install the fuse near the power source.
Specifications
OPERATING VOLTAGE: 10-30 VDC POWER: 20 WATTS ENERGY: 15 JOULES NOMINAL STANDARD FLASH RATE: EACH STROBE LIGHT OUTLET 70 QUAD FLASHES/MIN.
ALTERNATING PAIR 140 QUAD FLASHES/MIN.
POWER CONSUMPTION: 3 AMPS AVERAGE @ 13.8 VDC
!
WARNING!
The use of this or any warning device does not insure that all drivers can or will observe or react to an emergency warning signal. Never take the right-of-way for granted. It is your responsibility to be sure you can proceed safely before entering an intersection, driving against traffic, responding at a high rate of speed, or walking on or around traffic lanes. The effectiveness of this warning device is highly dependent upon correct mounting and wiring. Read and follow the manufacturer’s instructions before installing or using this device. The vehicle operator should insure daily that all features of the device operate correctly. In use, the vehicle operator should insure the projection of the warning signal is not blocked by vehicle components (i.e.: open trunks or compartment doors), people, vehicles, or other obstructions. This equipment is intended for use by authorized personnel only. It is the user’s responsi­bility to understand and obey all laws regarding emergency warning devices. The user should check all applicable city, state and federal laws and regulations. Public Safety Equipment, Inc., assumes no liability for any loss resulting from the use of this warning device. Proper installation is vital to the performance of this warning device and the safe operation of the emergency vehicle. It is important to recognize that the operator of the emergency vehicle is under psychological and physiological stress caused by the emergency situation. The warning device should be installed in such a manner as to: A) Not reduce the output performance of the system, B) Place the controls within convenient reach of the operator so that one can operate the system without losing eye contact with the roadway. Emergency warning devices often require high electrical voltages and/or currents. Properly protect and use caution around live electrical connections. Grounding or shorting of electri­cal connections can cause high current arcing, which can cause personal injury and/or severe vehicle damage, including fire. Do not touch the strobe light tubes, the strobe light head assemblies or the strobe power supply while the system is in operation. Wait 10 minutes after turning off the power from system before touching any internal componentry. PROPER INSTALLATION COMBINED WITH OPERATOR TRAINING IN THE PROPER USE OF EMERGENCY WARNING DEVICES IS ESSENTIAL TO INSURE THE SAFETY OF EMERGENCY PERSONNEL AND THE PUBLIC.
Unpacking and Pre-installation
Remove the power supply from the box and examine the unit for any transit damage. Report any damage to the carrier immediately. Inspect the supplied user parts kit, the 220HCL Hide-A-Way Strobe kit should contain:
A. 1 CPS220 Strobe Power Supply
B. 2 30 ft. cables
C. 2 Strobe Tube assemblies with connectors
D. 1 Parts Bag
E. 1 Installation Manual
3
Installation and Mounting
1. First install the CPS220 strobe power suppy in a protected location using the power supply itself as a template. THE POWER SUPPLY MUST BE MOUNTED TO A METAL SURFACE. Make sure all socket connectors are easily accesible.
3.543
4.000
3.500
FIGURE A
!
The Model CPS220 Strobe Power Supply is water resistant but NOT waterproof and should be located in an area protected from the weather and water.
WARNING!
Wiring
1. Install the strobe light heads in the desired locations.
2. String the 3-conductor cables between the lights and the power supply. Make sure the cable is secure along the chosen routing inside the vehicle to prevent it from damage by chafing or binding. Be sure to keep the cable away from engine hot spots.
3. Insert the pins on each end of the conductor cables into the AMP connectors. Each end of these cables has three pins factory crimped onto each of the three wires. See Figure B on next page for Pin Insertion order.
4
Male Amp connector to be mated with the Amp output socket on the Power Supply.
Insert wires with male pins into the proper locations in the male Amp connector: RED WIRE - POSITION 1 BLACK WIRE - POSITION 2 WHITE WIRE - POSITION 3
1 2 3
SHIELD WIRE CONNECT TO CHASSIS GROUND
FIGURE B
Female Amp
connector.
1
2
3
1 2 3
Amp wire harness attached to Strobe light head.
NOTE: IT IS IMPORTANT TO FOLLOW THE CORRECT COLOR CODE
WHEN INSERTING THE PINS INTO THE AMP 3 PIN CONNECTORS.
4. Connect the cables to the strobe light heads.
5. Next, plug the other end of the cable into one of the one of the two Light Head sockets (outputs) on the CPS220 strobe power supply.
POWER/CONTROL WIRE HARNESS ASSEMBLY
The Power/Control wire harness assembly consists of a 3 pin AMP style connector with: 1 red, 1 black, 1 white wire (see figure C). The Power/Control wire harness assembly must be connected to the power/control socket located on the CPS220 strobe light power supply. Use 18 gauge wire to extend the control harness wires to a customer supplied switch to complete the installation.
IMPORTANT: To extend the power (+) and ground (-) wires, use the following as a guide.
1 to 10 ft. use 16AWG wire 10 to 20 ft. use 14AWG wire 20 to 30 ft. use 12AWG wire 30 to 50 ft. use 10AWG wire
FIGURE C
RE D W IRE (+10 - 30VD C) BLACK W IRE (NEGATIVE)
W HITE W IR E (PATTERN SELECT)
1 2 3
Power/Control Wiring Harness
5
1. Connect the Power/Control wire harness assembly to a switch. To select one of the 10 different flash functions, simply touch the bare end of the white wire to the +power source for about one second as described in the FLASH PATTERN SELECTION section. After you have selected the desired flash pattern, you should cover the bare end of the white wire with heat shrinkable tubing to prevent an accidental short circuit. The flash pattern may also be selected remotely by the operator by connecting the white wire to the +power source through a Normally Open (NO) Momentary Push Button Switch.
2. Connect Black wires to a reliable ground.(-)
3. Connect Red Power wires from the Power /Control wire harness assembly to the power source (+) through a switch and an in-line fuse (5A for 12V operation or 2.5A for 24V operation).
FLASH PATTERN SELECTION
FLASH MODE
Any one of the 8 Flash Patterns may be selected by using the white wire to scroll through the patterns. Touch the white wire to + power for about 1 second and then remove it. The flash pattern will switch to the next pattern. The following patterns are available.
1. Quad Flash
2. Triple Flash
3. Double Flash
4. Single Flash
5. Active Flash
6. Variable Flash
7. Double-Double Flash
8. Triple-Triple Flash
WARNING: To achieve the maximum performance from your strobe tubes, do not mix Helix tubes and Linear Tubes. Mixing strobe tubes on the two outputs will cause one type to flash brighter than the other type in some modes and will reduce the life expectancy of the brighter flashing tube.
MAINTENANCE
The CPS220 Remote Strobe Power Supply has been designed to provide trouble free service. In case of difficulty, refer to the Troubleshooting section. Periodic inspection of power supply wiring, and strobe light head connections for shorted or open wires will assure trouble free operation. The primary cause of short circuits has been found to be wires passing through firewalls, roofs, etc.
6
Troubleshooting
NOTE: DO NOT TAMPER WITH THE POWER SUPPLY. THIS UNIT IS SOLD AS A COMPLETE MODULE, AND IS NOT DESIGNED FOR FIELD REPAIR. REMOVING THE TOP CASE CAN RESULT IN ELECTRIC SHOCK AND WILL VOID THE WARRANTY.
All CPS220 Remote Strobe Power Supply units are thoroughly tested before shipment. However, should you encounter a problem during installation or during the life of the product, refer to the guide below for information on troubleshooting. In most cases problems that occur will be related either to the power/control wiring, or to the strobe light head cables that connect them to the strobe power supply. In the event that the strobe power supply is at fault return the unit to the factory for service.
TROUBLESHOOTING GUIDE
PROBLEM CAUSE
External fuse blows
Light heads do not fire
Incorrect flash pattern
1. Power input wires reversed
2. Power supply failure
3. Incorrect fuse size
1. Cable connections loose at power supply or light head
2. Cable to light heads dam­aged and shorting to chassis
3. Cable terminated improperly in 3 pin AMP connector
4. Bad strobe tube
1. Wrong Flash Pattern is selected.
SOLUTION
1. Check power connections
2. Return for service
3. Replace with a 5A
1. Check all connections
2. Isolate damaged cable by disconnecting and reconnecting outputs one at a time. Repair or replace the damaged cable. (When other heads come back on the one that is disconnected is the shorted line.)
3. Check wire orientations at 3 pin connec­tors
4. Replace strobe tube assembly
1. See FLASH PATTERN SELECTION.
Flash patterns change continuously
1. Power Supply is in CYCLE FLASH mode. Proper opera­tion.
7
1. This is normal operation for this mode. If CYCLE FLASH MODE is not desired see FLASH PATTERN SELECTION.
WARRANTY
This product was tested and found to be operational at the time of manufacture. Provided this product is installed and operated in accordance with the manufacturer's recommendations, Public Safety Equipment guarantees the CPS220 for a period of 3 years from the date of purchase or delivery, whichever is later. Units demonstrated to be defective within the warranty period will be repaired or replaced at the factory service center at no cost.
Use of a lamp or other electrical load of a wattage higher than installed or recommended by the factory, or use of inappropriate or inadequate wiring or circuit protection causes this warranty to become void. Failure or destruction of the product resulting from abuse or unusual use and/or accidents is not covered by this warranty. Use of non-PSE components and assemblies may cause damage to the system and/or personal injury, and voids all warranties on PSE systems and components.
PSE shall in no way be liable for other damages including consequential, indirect or special damages whether loss is due to negligence or breach of warranty.
PSE MAKES NO OTHER EXPRESS OR IMPLIED WARRANTY INCLUDING, WITHOUT LIMITATION, WARRANTIES OF FITNESS OR MERCHANTABILITY, WITH RESPECT TO THIS PRODUCT.
PRODUCT RETURNS
In order to provide you with faster service, if you are going to return a product for repair or replacement*, please contact our factory to obtain a Return Goods Authorization Number (RGA number) before you ship the product to PSE. Write the RGA number clearly on the package near the mailing label. Be sure you use sufficient packing materials to avoid damage to the product being returned while in transit.
*PSE reserves the right to repair or replace product at its discretion. PSE assumes no responsibility or liability for expenses incurred for the removal and/or reinstallation of products requiring service and/or repair.
NEED HELP? Call our Technical Assistance Hotline - (314) 996-2800
Public Safety Equipment (UK), Ltd. Public Safety Equipment, Inc. Oldham Road, Rishworth 10986 N. Warson Road Halifax, West YorkshireENGLAND HX6 4QG St. Louis, Missouri 63114-2029USA Ph. 0422-824640 Fax 0422-824604 Ph. (314) 426-2700 Fax (314) 426-1337
Code 3 is a registered trademark of Public Safety Equipment, Inc. CycleFlash is a trademark of Public Safety Equipment, Inc.
Revision 1, 06/07 - Instruction Book Part No. T11480
©2007 Public Safety Equipment, Inc. Printed in USA
Loading...