Cobra CS9 Installation And Operation Manual

Gas Salamander
Mode l C S9
I N S T A L L A T I O N A ND O P E R A T I O N M A N U A L
242353-1
The reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless authorized previously in writing by the manufacturer.
© Copyright Moffat Ltd. December 2018.
Moffat Limited
Rolleston 7675 New Zealand
AUSTRALIA
Moffat Pty Limited Web: www.moffat.com.au E.Mail: vsales@moffat.com.au Main Office: (tel) +61 (03) 9518 3888
(fax) +61 (03) 9518 3838
Service: (tel): 1800 622 216 Spares: (tel): 1800 337 963
Customer Service: (tel): 1800 335 315
(fax): 1800 350 281
CANADA
Serve Canada Web: www.servecanada.com E.Mail: info@servecanada.com Sales: (tel): 800 551 8795 (Toll Free) Service: (tel): 800 263 1455 (Toll Free)
NEW ZEALAND
Moffat Limited Web: www.moffat.co.nz E.Mail: sales@moffat.co.nz Main Office: (tel): 0800 663328
UNITED KINGDOM
Blue Seal Web: www.blue-seal.co.uk
E.Mail: sales@blue-seal.co.uk Sales: (tel): +44 121 327 5575
(fax): +44 121 327 9711 Spares: (tel): +44 121 322 6640 (fax): +44 121 327 9201 Service: (tel): +44 121 322 6644 (fax): +44 121 327 6257
UNITED STATES
Moffat Web: www.moffat.com Sales: (tel): 800 551 8795 (Toll Free)
(fax): +1 336 661 9546 Service: (tel): 866 673 7937 (Toll Free) (tel): +1 336 661 1556 (fax): +1 336 661 1660
REST OF WORLD
Moffat Limited Web: www.moffat.co.nz E.Mail: export@moffat.co.nz
Model Numbers Covered in this Specification
General
Gas Supply Requirements
Gas Connection
Dimensions
Installation Requirements
Unpacking
Location
Clearances
Wall Mounting (To Non-Combustible Wall Only)
Gas Connection
Commissioning
Operation Guide
Description of Controls
Lighting the Main Burners
Racking System
Cooking Recommendations
General
Racking
Stainless Steel Surfaces
Vitreous Enamel Surfaces
Crumb / Drip Tray
Periodic Maintenance
Gas Control Valve Re-Greasing
Gas Conversion Procedure
Gas Specifications
We are confident that you will be delighted with your Cobra Series Salamander, and it will become a most
valued appliance in your commercial kitchen.
To ensure you receive the utmost benefit from your new Cobra Appliance, there are two important things you can do.
Please read this instruction book carefully and follow the directions given. The time taken will be well spent.
If you are unsure of any aspect of the installation, instructions or performance of your appliance, contact your Cobra Series dealer promptly. In many cases a phone call could answer your questions.
These instructions are only valid if the country code appears on the appliance. If the code does not
appear on the appliance, refer to the supplier of this appliance to obtain the technical instructions for
adapting the appliance to the conditions for use in that country.
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS
APPLIANCE.
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS, ARE TO BE POSTED IN A PROMINENT LOCATION. THIS
INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER.
GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF FIRE.
THE APPLIANCE MUST NOT BE LEFT ON UNATTENDED. IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICEMAN TO ENSURE CORRECT AND SAFE
OPERATION OF YOUR APPLIANCE IS MAINTAINED.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER
APPLIANCE.
DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.
2
3
- United Kingdom:
Category: II
2H3P
(20, 30 / 37).
Flue Type: A1.
NOTE:
(*) Measure burner operating pressure at manifold test point with both burners operating at 'High Flame' setting. Operating pressure is ex-factory set and is not to be adjusted, apart from when
converting between gases, if required. Refer to
‘Gas Conversion’ Section in this manual for further
details.
- All Other Markets:
NOTE:
(*) Measure burner operating pressure at
manifold test point with both burners operating at the 'High Flame' setting.
NAT, LPG & Butane Only - Operating pressure is
ex-factory set and is not to be adjusted, apart from when converting between gases, if required.
(**) TOWN GAS Only - Burner operating pressure
is to be adjusted using the adjustable gas regulator supplied.
Refer to ‘Gas Conversion and Specifications
section in this manual for further details.
Gas supply connection point is located at the back, 130mm from right hand side of the appliance, and entered from beneath the appliance.
Connection is ½ BSP male.
Model Covered in this Specification -
CS9 Gas Salamander.
A commercial heavy duty, wall mounted gas fired infra-red grilling Salamander for a wide range of foods. Cobra Salamanders feature independently controlled heat zones for left and right side of the cooking area.
Two high speed infrared surface combustion burners in the ceiling of the cavity are independently operated with the left and right hand side controls. Each main burner is provided with flame failure feature for ease of operation and safety. The main burners are manually lit with each burner having LO to HI settings to provide full cooking flexibility.
Rack supports have 4 fixed height positions offering flat and angled rack positioning.
Cobra Salamanders come standard with a crumb / drip tray for collection of cooking grease and crumbs from the cooking operations. The tray is easily removed (slide out) for cleaning and to provide easy cleaning access to the rear and sides of the cooking area.
A Branding Plate is available as an optional accessory item and provides a deep grooved / ribbed cooking surface which can be used with this racking system. Refer to the Replacement Parts List. The Branding Plates can be fitted onto the standard wire rack allowing ease of change as required between menus.
- Australia:
- New Zealand:
Input Rating
31.5 MJ/hr 31.5 MJ/hr
Supply Pressure
1.13 - 3.4 kPa 2.75 - 4.5 kPa
Burner Operating Pressure (*)
1.0 kPa (*) 2.55 kPa (*)
Gas Connection
½" BSP Male
Input Rating
31.5 MJ/hr 31.5 MJ/hr
Supply Pressure
1.13 - 3.4 kPa 2.75 - 4.5 kPa
Burner Operating Pressure (*)
1.0 kPa (*) 2.55 kPa (*)
Gas Connection
½" BSP Male
Heat Input (nett)
8.8 kW 8.8 kW
Gas Rate
0.84 m3/hr 0.63 kg/hr
Supply Pressure
20 mbar 37 mbar
Burner Operating Pressure (*)
10 mbar (*) 26 mbar (*)
Gas Connection
½" BSP Male
Input Rating
31.5 MJ/hr
Supply Pressure
2.75 - 4.5 kPa
Burner Operating Pressure (*)
2.55 kPa (*)
Gas Connection
½" BSP Male
Input Rating
31.5 MJ/hr 40 MJ/hr
Supply Pressure
1.13 - 3.4 kPa 0.76 - 1.50 kPa
Burner Operating Pressure (*)
1.0 kPa (*) 0.63 kPa (*)
Gas Connection
½" BSP Male
4
CS9 Gas Salamander.