Cobra CR6 Series, CR6D, CR9 Series, CR6C, CR6B Installation And Operation Manual

...
242357-3
Static Oven R a n g e
Models:
CR 6 ( 600 mm) CR 9 ( 900 mm)
I N S T A L L A T I O N A N D O P E R A T I O N M A N U A L
The reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless authorized previously in writing by the manufacturer.
In line with policy to continually develop and improve its products, Moffat Ltd. reserves the right to change the specifications and design without prior notice.
© Copyright Moffat Ltd. September 2019.
Moffat Limited
Rolleston 7675 New Zealand
AUSTRALIA
Moffat Pty Limited E.Mail: vsales@moffat.com.au Main Office: (tel): +61 (03) 9518 3888
(fax): +61 (03 9518 3833
Service: (tel): 1800 622 216 Spares: (tel): 1800 337 963 Customer Service: (tel): 1800 335 315 (fax): 1800 350 281
CANADA
Serve Canada Web: www.servecanada.com E.Mail: info@servecanada.com Sales: (tel): 800 551 8795 (Toll Free) Service: (tel): 800 263 1455 (Toll Free)
NEW ZEALAND
Moffat Limited Web: www.moffat.co.nz E.Mail: sales@moffat.co.nz Main Office: (tel): 0800 663328
UNITED KINGDOM
Blue Seal Web: www.blue-seal.co.uk E.Mail: sales@blue-seal.co.uk Sales: (tel): +44 121 327 5575
(fax): +44 121 327 9711 Spares: (tel): +44 121 322 6640 (fax): +44 121 327 9201 Service: (tel): +44 121 322 6644 (fax): +44 121 327 6257
UNITED STATES
Moffat Web: www.moffat.com
Sales: (tel): 1-800 551 8795 (Toll Free)
(tel): 336 661 1556 (fax): 336 661 9546
Service: (tel): 866 673 7937 (Toll Free)
REST OF WORLD
Moffat Limited Web: www.moffat.co.nz E.Mail: export@moffat.co.nz
Model Numbers Covered in this Specification
General
Gas Supply Requirements
Gas Connection
Dimensions
Installation Requirements
Unpacking
Assembly
Location
Clearances
Gas Connection
Commissioning
Operation Guide
Description of Controls
Open Burners
Griddle
Oven
General
After Each Use
Daily Cleaning
Weekly Cleaning
Periodic Maintenance
Open Burners
Griddle Burners
Oven
Gas Conversion Procedure
Gas Specifications
We are confident that you will be delighted with your Cobra Series Ranges, and it will become a most valued appliance in your commercial kitchen.
To ensure you receive the utmost benefit from your new Cobra Series Appliance, there are two important things you can do.
Please read this instruction book carefully and follow the directions given. The time taken will be well spent.
If you are unsure of any aspect of the installation, instructions or performance of your appliance, contact your Cobra Series Range dealer promptly. In many cases a phone call could answer your question.
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS
APPLIANCE.
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT LOCATION. THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER.
GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF FIRE.
THE APPLIANCE MUST NOT BE LEFT ON UNATTENDED. IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICEMAN TO ENSURE CORRECT AND SAFE
OPERATION OF YOUR APPLIANCE IS MAINTAINED.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER
APPLIANCE.
DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.
2
3
The CR6 Oven is a 490mm (internal) full width oven
fitted with French style opening doors. The oven burner is a 24-26 MJ oven burner and has pilot and flame failure with piezo ignition.
The CR9 Oven is a 780mm (internal) full width oven fitted with French style opening doors. The oven burner is a 28-30 MJ oven burner and has pilot and flame failure with piezo ignition.
The Range has an easy clean stainless steel external finish.
Model Covered in this Specification -
CR6D[1] Range 4 Open Burners. CR6C[1] Range 2 Burners + 300mm Griddle. CR6B Range 600mm Griddle.
CR9D[1] Range 6 Open Burners. CR9C[1] Range 4 Burners + 300mm Griddle. CR9B[1] Range 2 Burners + 600mm Griddle. CR9A Range 900mm Griddle.
[1] - Open Burner Options;
- Standard Option. F - Flame Failure Protection.
A heavy duty, general purpose Gas Range created for compact modular kitchens and available in a 600mm and 900mm wide option. It has a high option Cooktop / Griddle arrangement and is available on adjustable front feet and robust rear rollers. Open Burners have either Standard or with Flame Failure Protection as an option.
Griddles are available in 300mm, 600mm and for the CR9 Gas Static Oven Range, 900mm options and are fitted with pilot, flame failure and piezo ignition as standard.
- United Kingdom:
NOTE:
(*) Measure burner operating pressure at manifold test point with two burners operating at 'High
Flame' setting. Operating pressure is ex-factory set and is not to be adjusted, apart from when
converting between gasses, if required. Refer to ‘Gas Conversion and Specifications’ section in this
manual for further details.
Open Burner
(each)
Griddle
(each 300mm
section)
Oven Open
Burner
(each)
Griddle
(each 300mm
section)
Oven
CR6 CR9 CR6 CR9
Heat Input (net)
Nominal 5.0 kW 5.0 kW 6.5 kW 7.5 kW 4.6 kW 5.0 kW 6.0 kW 7.5 kW Reduced
1.7 kW 1.5 kW 1.1 kW 2.2 kW 1.5 kW 2.2 kW 1.05 kW 2.3 kW
Gas Rate (net)
Nominal
0.53 m3/hr 0.53 m3/hr 0.51 m3/hr 0.79 m3/hr 0.36 kg/hr 0.39 kg/hr 0.47 kg/hr 0.58 kg/hr
Reduced
0.18 m3/hr 0.16 m3/hr 0.14 m3/hr 0.23 m3/hr 0.12 kg/hr 0.17 kg/hr 0.09 kg/hr 0.18 kg/hr
Supply Pressure
20 mbar 37 mbar
Burner Operating Pressure (*)
28 mbar 10 mbar
Gas Connection ¾” BSP Male ¾” BSP Male
4
Gas supply connection point is located at the rear of the appliance, approximately 130mm from the right hand side, 19mm from the rear and 656mm from the floor and is reached from beneath the appliance. (Refer to the ‘Dimensions’ below).
For all Appliance Options, gas connection is 3/4” BSP male.
CR6 Model
CR6 Model - Cooktop Options
5
Gas supply connection point is located at the rear of the appliance, approximately 130mm from the right hand side, 19mm from the rear and 656mm from the floor and is reached from beneath the appliance. (Refer to the ‘Dimensions’ below).
For all Appliance Options, gas connection is 3/4” BSP male.
CR9 Model
CR9 Model - Cooktop Options
6
NOTE: It is most important that this appliance is installed correctly and that operation is correct before use. Installation shall comply with local, gas and health and safety requirements.
This appliance shall be installed with sufficient ventilation to prevent the occurrence of unacceptable concentrations of health harmful substances in the room that the appliance is installed in.
Cobra Series Ranges are designed to provide years of satisfactory service and correct installation is essential to achieve the best performance, efficiency and trouble-free operation.
This appliance must be installed in accordance with National installation codes and in addition, in accordance with relevant National / Local codes covering gas and fire safety.
United Kingdom:
Gas Safety (Installation and Use) Regulations 1998.
BS6173 - Installation of Catering Appliances.
BS5440 1 & 2 - Installation Flueing & Ventilation.
Ireland:
IS 820 - Non Domestic Gas Installations.
Installations must be carried out by qualified service persons only. Failure to install equipment to the
relevant codes and manufacturer’s specifications
shown in this section will void the warranty.
Components having adjustments protected (e.g. paint sealed) by manufacturer, are only to be adjusted by a qualified service agent. They are not to be adjusted by the installation person.
Remove all packaging and transit protection
from the appliance including all protective plastic coating from the exterior stainless steel panels.
Check equipment and parts for damage.
Report any damage immediately to the carrier and distributor.
Report any deficiencies to the distributor who
supplied the appliance.
Check that the available gas supply is correct to
that shown on the rating plate located on the front lower corner of the R/H side panel.
If the Legs and Rear Rollers are not fitted, carry out the procedure below to fit Front Legs and Rear Rollers.
NOTE: This appliance is fitted with adjustable feet to enable the appliance to be positioned securely and level. This should be carried out on completion of the gas connection.
1. Remove all loose components from the top of the cooktop range and from inside the oven.
2. Remove screws securing transit plates to the front corners of the transit pallet.
3. Tilt the oven onto it’s back and unscrew the transit bolts from the front leg mounting plates.
4. Remove front legs from carton and screw onto the front leg mounting plates.
NOTE: The front legs are adjustable. Once the rear rollers are fitted and the appliance is in
it’s operating position, the
front legs can be adjusted to level the appliance.
5. Remove rear rollers from carton and attach to rear leg ring plate. Secure with 10mm bolts supplied.
6. Lift appliance back onto it’s legs / rollers.
7. Place the cooktop in its final operating position and use the adjustable feet to level the appliance.
8. Refit all items removed at Item 1 above.
Attach with Bolt supplied.
Transit Plate.
Transit Bolt.
Adjustable Foot
Adjustable
Front Leg
7
1. This appliance must be installed in a suitably ventilated room to prevent dangerous build up of combustion products.
2. Installation must allow for a sufficient flow of fresh air for the combustion air supply.
3. Never directly connect a ventilation system to
the appliance flue outlet.
4. Position the appliance in its approximate
working position.
5. All air for burner combustion is supplied from
underneath the appliance. The legs must always be fitted and no obstructions placed on the underside or around the base of the appliance, as obstructions will cause incorrect operation and / or failure of the appliance.
6. Components having adjustments protected
(e.g. paint sealed) by manufacturer are only to be adjusted by a qualified service agent. They are not to be adjusted by the installation person.
NOTE: Do not obstruct or block the appliances flue. Never directly connect a ventilation system to the appliance flue outlet.
NOTE: Only non-combustible materials can be used in close proximity to this appliance.
Any gas burning appliance requires adequate clearance and ventilation for optimum and trouble free operation. The following minimum installation clearances are to be adhered to:
* Side clearances can be 50mm when adjacent
surface is at least 100mm below cooking surface.
LH / RH
Side
250mm (*) 0mm
Rear 100mm 0mm
NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED SERVICE PERSON.
1. Cobra Series Oven Ranges do not require an electrical connection, they function totally on the gas supply only.
2. It is essential that the gas supply is correct for the appliance to be installed and that adequate supply pressure and volume are available. The following checks should be made before installation:-
a. The Gas Type the appliance has been
supplied for is shown on coloured stickers located above the gas entry point and next to the rating plate. Check that this is correct for the gas supply the appliance is being installed for. The gas conversion procedure is detailed in the Gas Conversion Instruction Sheet for this appliance.
b. Supply Pressure required for this appliance is
shown in the 'Specifications' section of this manual. Check the gas supply to ensure that adequate supply pressure exists.
c. Input Rate of this appliance is also shown on
the Rating Plate located on the front lower corner of the R/H side panel, and in the 'Specifications' section of this manual. The input rate should be checked against the available gas supply line capacity. Particular
note should be taken if the appliance is being added to an existing installation.
NOTE: It is important that adequately sized piping runs directly to the connection joint on the appliance, with as few tees and elbows as possible to give maximum supply volume.
3. Fit the gas regulator supplied, into the gas supply line as close to the appliance as possible.
NOTE: Gas pressure regulator provided with this appliance is convertible between Natural Gas and LPG as per the ‘Gas Conversion Section’ in this manual. Ensure the regulator is converted to the correct gas type that the appliance will operate on.
Regulator outlet pressure is fixed ex-factory for the gas type that the regulator is converted to and it is NOT to be adjusted.
The regulator connections are 3/4” BSP female. The connection to the appliance is 3/4” BSP male.
(Refer to the 'Specifications' Section for the gas supply location dimensions).
CR6 Cooktop CR9 Cooktop
Natural Gas
30 m3/hr minimum 41 m3/hr minimum
LPG / Propane
31 m3/hr minimum 43 m3/hr minimum
+ 19 hidden pages