Cobra 4600 CAN, 4600 PLIP Installation Manual

4600 CAN/PLIP
INSTALLATION MANUAL
INSTALLATION MANUAL 4600 CAN/PLIP
2
Summary
1.KIT CONTENTS.................................................................................................................................................3
documents, Data Linker tool, Antares software, how to defi ne the installation solution) ......................................3
3.SYSTEM’S CONFIGURATION ..........................................................................................................................4
4. HOW TO PREPARE PIN CODE CARD ............................................................................................................5
5.INSTALLATION PROCEDURE (system’s component locations, electrical connections) .................................5
6.ACTIVE FUNCTIONALITIES (descriptions) .....................................................................................................8
- ELECTRIC DIAGRAMS
7.PROGRAMMABLE FUNCTIONS (descriptions) ............................................................................................18
8. HOW TO PROGRAM FUNCTIONALITIES, COBRA REMOTE CONTROLS AND DRIVER CARDS SELF
LEARNING PROCEDURE ................................................................................................................................20
9. FUNCTIONAL TEST .......................................................................................................................................21
10. CAN INDEX MANUAL SELECTION .............................................................................................................21
11. SELF LEARNING PROCEDURE REQUIRED TO REPLACE THE MAIN UNIT OR THE WIRELESS SIREN
REPLACEMENT. ................................................................................................................................................22
12. DOCUMENTS HANDOVER .........................................................................................................................22
13. TECHNICAL FEATURES ..............................................................................................................................22
14. UK MARKET .................................................................................................................................................23
INSTALLATION MANUAL 4600 CAN/PLIP
3
1. - KIT CONTENTS.
The following are the main parts supplied in the kit:
- Main alarm unit.
- Remote controls and/or Driver Card (if provided).
- Wireless back-up battery siren or wired siren, loudspeaker.
- Main unit universal wiring harness.
- Siren wiring harness.
- Siren bracket.
- Ultrasonic sensors.
- Installation accessories.
- LED / control button.
- Quick reference user manual.
- Pin Code card.
2. - INTRODUCTION.
The main unit of this system is equipped with an on board CAN interface (Controller Area Network) that allows the data reading from the vehicle CAN network. In can also be installed confi gured as PLIP, with this solution the unit is not connected to the CAN network, but to the central door locking motors, to the door locking switches and/or to the direction lights.
It can be armed/disarmed by the vehicle original remote control, with the Cobra one or with the Driver Card (if provided). This manual contains all information required to fi t the system on 12V battery vehicles with the negative pole connected
to the vehicle body.
HOW TO ACCESS TO THE VEHICLE SPECIFIC TECHNICAL DOCUMENTS, DATA LINKER TOOL, ANTARES SOFTWARE.
Access to the web site www.cobra-at.com > Installer area and register yourself to be allowed to download the technical documentation.
Data Linker programming tool and the software “Antares” are required to customize the product for the destination vehicle. Data Linker is composed by a USB interface module, a 12V DC power supply, a CD containing the software “Antares”
and the required instructions. Product specifi c wiring harness are also supplied to connect the USB module to the product main unit.
Antares allows to confi gure/customize and to program the CAN/PLIP software for the destination vehicle using your computer.
HOW TO DEFINE THE INSTALLATION SOLUTION.
Access to the web site www.cobra-at.com > Login > user ID > password > access > professional area and, clicking on the menu, supply all the requested destination vehicle information (in the example a VW Polo, year 2011) as the information of the product to install, in this case the 4600 range.
VEHICLE TYPE.
Auto - Car
PRODUCT TYPE.
Antifurti auto - Car alarms
BRAND LIST.
Volkswagen
MODEL LIST.
Polo
INSTALLATION MANUAL 4600 CAN/PLIP
4
The list on the right side of the screen shows the product families. Clicking on the link you will get the full application list available for the destination vehicle for the product family selected. Check at fi rst if there is a CAN application available, it offers the best compromise amoung functionalities offered/fi tting time.
If no one CAN product installation proposal is available, make the same research clicking on “PLIP alarm” range AK4600 – 4400 Plip.
If there is an installation solution clicking on the vehicle model you can download the vehicle specifi c installation sheet.
If no one CAN and no one Plip installation proposal is available, choose again the vehicle type then, as “Product type” select “Application manuals”. The list on the right side of the screen shows the application manuals available, click on “Application manuals” to get the application manual list, then download the installation manual of the 4600 for the Plip confi guration.
3. - SYSTEM’S CONFIGURATION.
Be sure to have connected all Data Linker components and to have power supplied the system. Run Antares.
As soon as Antares is starting, it automatically checks - if the computer is connected to internet - if the installed version is the most updated one and, if not, it proposes its update.
We recommend to download all times the last update.
Proceed as follow:
A. Select the language.
B. Select “alarm and modules”.
C. Select product “4600 “ as “1 wire” or “2 wire”.
D. Select the procedure “fi rmware update”.
E. Click on “proceed”.
F. Select the vehicle brand.
G. Select the vehicle model.
H. Select the vehicle model year.
I. Click on “proceed”.
L. Confi rm and continue.
M. Wait until the programming confi rmation window appears.
Additional software installation and tool usage details are available on the specifi c manual supplied in the Data Linker kit or in the Cobra web site, professional area, Application manuals.
INSTALLATION MANUAL 4600 CAN/PLIP
5
4. - HOW TO PREPARE THE PIN CODE CARD.
Remove the separate PIN Code label from the back of the system main unit and place onto the supplied PIN Code Card.
www.cobra-at.com
PLACE HERE THE PIN
CODE LABEL
PERSONAL IDENTIFICATION CODE
4C4415A2A
S/N 0003 050524
PIN CODE
1122
5. - INSTALLATION PROCEDURE.
System’s component positioning.
As much as the components of the system will be placed in secure and diffi cult to access positions as higher the protection level will be.
WARNING: each element must be positioned so that it does not interfere with moving parts.
Alarm unit.
It must be fi tted inside the vehicle far away from heating sources, paying attention to keep the main connector oriented down.
Siren.
It can be installed in the engine bay as inside the vehicle far away from heating sources paying attention to keep the main connector oriented down.
Ultrasonic volumetric sensor.
The ultrasonic transducers must be fi xed to the top of the A pillars pointed towards the rear window or to the top of the C pillars pointed towards the windscreen. Their orientation should be as much as possible parallel to the side windows.
Emergency LED/control button
It must be fi tted on the dashboard with its LED in a in sight position. The pushbutton should be easily accessible by the driver.
Bonnet pushbutton.
The installation of the supplied pushbutton is required if the vehicle is not yet equipped with the original one. The specifi c vehicle CAN/PLIP installation sheet supplies this info.
INSTALLATION MANUAL 4600 CAN/PLIP
6
Antennas.
The RF antennas positioning (for both the main unit and the siren) is crucial for a proper system’s performance . They must not be cut, wrapped, connected to any other cables or to the vehicle body and they must be kept separate from the main wiring harness and as far as possible from metallic parts.
Electrical connections.
WARNING: Disconnect the negative lead from the battery before continuing with the installation.
Pay attention when joining two or more wires. Avoid to make “quick connections” that do not ensure a good quality. Also make sure that the wires of the Cobra 4600 are routed so that they follow the original wiring of the vehicle to which
they should be joined with the raps.
The addition of fuse is required as specifi ed in the main connection diagram.
26 ways connector J pin-out for CAN confi gurations
J-1 and J-2 Engine crank inhibition: to get the maximum security level to the system connect the two wires as shown
in the electrical diagrams to prevent the engine starter running.
During the cranking phase, measure the value of the current in the circuit
that has been interrupt, to make sure that it does not exceed the technical specifi cations of the product.
Install an additional relay if required.
J-3 Logic blinker output: make the connection if required by the speci c vehicle CAN installation sheet.
J-4 Power blinker output: make the connection if required by the speci c vehicle CAN installation sheet.
J-5 Logic blinker feedback input or power blinker output: make the connection if required by the speci c
vehicle CAN installation sheet.
J-6 analogic input: make the connection if required by the speci c vehicle CAN installation sheet.
J-7 analogic input: make the connection if required by the speci c vehicle CAN installation sheet.
J-8 Cobra bus: communication line for the connection of compatible Cobra sirens and sensors.
J-9 and J-10 CAN H/L: to connect as shown in the speci c vehicle CAN installation sheet.
J-11 Pager negative output: low power control signal for triggering a pager device or a telematic one. Active low during
alarm time.
J-12 CDL unlock negative output: low power control signal to unlock central door locking. Activated by the Cobra remote control , if provided (see electrical diagram F).
J-13 analogic input: make the connection if required by the speci c vehicle CAN installation sheet.
J-14 12V connection (+30): the positive supply must be connected to a vehicle positive connection point upstream of the
fuse box. Fit a 15A fuse as close as possible to the connection point.
J-15 GND connection: the ground must be connected to a factory earth point or directly to the negative pole of the battery.
J-16 Negative output for modules: active when the system is armed. To be used for the connection of compatible
Cobra modules.
J-17 Horn/loudspeaker negative output: to program in line with the connected device. See electric diagrams and functionalities programming tables. The output set automatically as per selected device, for horn choose also fi x or intermittent.
J-18 Positive input: when connected to positive it disables permanently the automatic ultrasonic protection exclusion normally working when windows are left open.
J-19 analogic input: make the connection if required by the speci c vehicle CAN installation sheet.
J-20 analogic input: make the connection if required by the speci c vehicle CAN installation sheet.
J-21 negative input to enter in programming procedure/to connect bonnet pushbutton: if connected to
ground the system will enter in the programming procedure for all applications not able to detect the original bonnet pushbutton. If the siren is a wireless one this input must not be used for the bonnet pushbutton connections. For wired siren or loudspeaker this input must be used for the connection of the bonnet pushbutton as indicated in the specifi c vehicle CAN installation sheet.
Loading...