COATS Kit 85608163 User Manual

ProGuard Tire Changer Bracket Kit 85608163
For use with COATS EL-X™ Express Lane Inflation System
Hennessy Industries • 1601 J. P. Hennessy Drive, LaVergne, TN USA 37086-3565 (800) 688-6359 • (615) 641-7533 • (615) 641-5104 FAX • www.ammcoats.com
Instructions
Before beginning this modification or attempting any maintenance, remove the electrical power and air source from the machine; also, bleed off any stored compressed air by exhausting through the air blast foot valve.
1. At tower remove two screws and reserve the
hardware.
2. Position cage bracket at tower and use reserved screws to fasten cage bracket to machine tower, then secure.
3. Use two 3/8-16 x 7/8 inch HSWF screws and two 3/8-16 UNC nuts to fasten cage bracket to inflation cage, then secure.
4. Refer to the Tire Inflation Cage Kit 85607770 instructions for its attachment and setup procedure.
Position Bracket
Attach Bracket To Cage
ProGuard Tire Changer
Use Existing Hardware
5. Reconnect the air and electric supply to the machine. Test the machine for full function before returning the machine to operation.
Location of Tire Inflation Cage
Provide at least three feet of clear space between the Tire Inflation Cage and building walls. When a tire fails, the explosive release of air will throw all movable objects in the path of the expanding compressed air.
Trajectory
Zone
Trajectory
Zone
3-feet
Wall
Cage Attached Three Feet From Wall
85608164 00 07/12 1 of 1 © Copyright 2012 Hennessy Industries and COATS All Rights Reserved