ProGuard Tire Changer
Bracket Kit 85608163
For use with COATS EL-X™ Express Lane
Inflation System
Hennessy Industries • 1601 J. P. Hennessy Drive, LaVergne, TN USA 37086-3565 (800) 688-6359 • (615) 641-7533 • (615) 641-5104 FAX • www.ammcoats.com
Instructions
Before beginning this modification or attempting
any maintenance, remove the electrical power and air
source from the machine; also, bleed off any stored
compressed air by exhausting through the air blast foot
valve.
1. At tower remove two screws and reserve the
hardware.
2. Position cage bracket at tower and use reserved
screws to fasten cage bracket to machine tower, then
secure.
3. Use two 3/8-16 x 7/8 inch HSWF screws and two
3/8-16 UNC nuts to fasten cage bracket to inflation
cage, then secure.
4. Refer to the Tire Inflation Cage Kit 85607770
instructions for its attachment and setup procedure.
Position Bracket
Attach Bracket
To Cage
ProGuard
Tire Changer
Use Existing
Hardware
5. Reconnect the air and electric supply to the
machine. Test the machine for full function before
returning the machine to operation.
Location of Tire Inflation Cage
Provide at least three feet of clear space between
the Tire Inflation Cage and building walls. When a tire
fails, the explosive release of air will throw all movable
objects in the path of the expanding compressed air.
Trajectory
Zone
Trajectory
Zone
3-feet
Wall
Cage Attached Three Feet From Wall
85608164 00 07/12 1 of 1 © Copyright 2012 Hennessy Industries and COATS All Rights Reserved