CMA Dishmachines GW-100 Installation Manual

GW-100 Carousel Glasswasher
800-854-6417
Quick Setup Instructions
WARNING: Electrical and plumbing
connections need to be made by a licensed service person and comply with all Federal, State and Local Health, Electrical, Plumbing and Safety codes.
POWER BLOCK
1
HEATER THERMOSTAT
6
THERMOMETER
6
DRAIN CONNECTION
3
LEVELING LEGS
4
POWER SWITCH
5
GW-100 FRONT VIEW
PRIME DETERGENT
CONCENTRATION
PRIME SANITIZER
CONCENTRATION
PRIME RINSE
CONCENTRATION
ON
OFF
FLUSH
COLD WATER
INLET
HOT WATER
INLET
2
2
STEP
1
(N)
L2
L1
GROUND
Connect L1 and L2 leads to the power block and one ground. 110/120V.
STEP
4
STEP
2
Connect water lines (hot 140F/160F) and (cold 75F) to water solenoid valves.
STEP
5
ON
OFF
FLUSH
PRIME RINSE
CONCENTRATION
STEP
3
1"AIR GAP
STEP
WALL
DRAIN
FLOOR DRAIN
6
140
Level dishmachine by adjusting leveling legs. Dishmachine must be level front and back to ensure proper performance.
Flip power "on-off/flush" switch to "ON" position. Wash tank will automatically fill.
Adjust heater thermostat to 140F.
3-2008
GW-100 Carousel Glasswasher
800-854-6417
Quick Setup Instructions
WARNING: Electrical and plumbing
connections need to be made by a licensed service person and comply with all Federal, State and Local Health, Electrical, Plumbing and Safety codes.
AUTO FILL TIMER
7
OVERFLOW
DRAIN TUBE
9
PRIMER
PUSH BUTTONS
GW-100 FRONT VIEW
TUBE
STIFFENER
CHEMICAL
TUBING
PRIME DETERGENT
CONCENTRATION
PRIME SANITIZER
CONCENTRATION
PRIME RINSE
CONCENTRATION
ON
OFF
FLUSH
ROCKER
SWITCH
10
PRIME DETERGENT
CONCENTRATION
PRIME SANITIZER
CONCENTRATION
PRIME RINSE
CONCENTRATION
ON
OFF
FLUSH
CHEMICAL
STORAGE AREA
8
8
4
5
STEP
7
6
72
INIT.
10
MIN
3
2
7
1
MAX
9
8
INPUT
LOAD
3
2
1
STEP
8
3/4"
Adjust auto-fill timer to set water level.
STEP
Insert tube stiffener with chemical tubing into corresponding chemical dispensers.
10
BLUE RED
WHITE
DRAIN TRAY AND
WASTE COLLECTOR
STEP
PRIME
DETERGENT
CONCENTRATION
9
PRIME SANITIZER
CONCENTRATION
PRIME RINSE
CONCENTRATION
Push each of the chemical prime buttons and hold until the chemical feed tubes are full.
Start conveyor by flipping rocker switch to
"ON" position.
Available Option: Drain tray and waste
collector. (Recommended)
3-2008
Loading...