1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
CLASSIC CONVECTION STEAMERS
15 PSI BOILER BASE STYLE
CONVECTION
Cleveland Classic Series
STEAMERS
TWO COMPARTMENT, PRESSURELESS
24, 36 OR 48 KW ELECTRIC STEAM GENERATOR
36” WIDE CABINET BASE DESIGN
Cleveland Standard Features
II
Cooking Capacity for up to six 12˝ x 20˝ x 21⁄2˝ deep Cafeteria Pans.
II
Pressureless cooking with forced convection steam, permitting
doors to be opened while cooking continues.
II
Solid State Controls operate water level and safety functions.
Each compartment is equipped with a 60 minute mechanical
II
timer, separate bypass switch for constant steaming and a
cold water condenser for superior cooking results.
II
Instant Steam Standby Mode: Holds generator at steaming
temperature. Allows unit to start cooking instantly.
II
Durable 14 Gauge Stainless Steel Construction:
For Compartment Door and Steam Cooking Cavity.
II
Separate Main Power Switch for “On/Off”
II
Exclusive Steam Cooking Distribution System:
sive Convection Jets produce a high velocity convection steam
without fans. Coved Corner design in cooking compartment distributes heat evenly and is easy to keep clean. Creased top & bottom enhance drainage. Cold Water Condenser for each
compartment maintains a dry steam. Fully insulated cooking compartment for thermal efficiency. Removable Stainless Steel Slide
Racks for easy cleaning.
II
Heavy duty, one piece, solid compartment door design
with replaceable door gasket.
II
Left Hand Door Hinging: Compartment Doors hinged left,
controls on the right.
II
Modular Cabinet Base with Hinged Door.
II
Electric Steam Generator: Automatic Water Fill on start up.
II
Automatic Generator Drain at shutdown: Contains a “Water
Jet” Spray Rinse Cleaning Cycle to keep drain clear.
II
Automatic Water Level Control System with Low Water
Power Cut-off Circuit.
II
Steam generator equipped with High Limit Pressure Safety
Switch, 15 psi Safety Valve, and Steam Generator Pressure
Gauge.
II
Secondary Low Water Cut-Off, factory installed (CALE)
(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN.
MT. NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY, Wash.
DC)
II
NSF Certified 6˝ Stainless Steel Legs with adjustable
flanged feet for a one inch level adjustment.
Standard voltage 208 or 240 volts, 60 Hz, 3 phase.
II
II
All Controls are serviceable from the front.
The exclu-
MODELS: 36-CEM-24 36-CEM-48
36-CEM-36
Shown with optional
Electronic Timer
Short Form Specifications
Shall be Two Compartments, CLEVELAND Convection Steamer, Model 36CEM- _____ , Electric Steam Generator, _____ KW, _____ volts, _____ phase, 3
wire. Solid State Controls operate timing, water level and safety functions.
Electric Steam Generator with Automatic Water Fill on start-up and Automatic
Blowdown with additional Manual Drain Valve. For each cooking compartment: 60 minute Mechanical Timer, Manual Operation Mode and Cold Water
Condenser. Type 304 Stainless Steel cooking compartment.
Options & Accessories
Ë Right Hand Door Hinging, Controls on the Left (DHR)
Ë Electronic Timer with Compensating Load Feature (ETC)
Ë ON/OFF Steam Switch for compartment controls (MC)
Ë Compartment Door Steam Shut Off Switch (SCS)
Ë Cafeteria pans in depths of 1˝, 2
Ë Power Take Off Kit (EPTO), Kettle Interconnect Kit (IMK)
Ë Voltages other than standard
Ë Stainless Steel Base Frame (FSS)
Ë Correctional Packages
Ë Boiler Descaling Pump Kit (107142)
Ë Water Filters
1
⁄2˝, 4˝ and 6˝
SECT. III PAGE 9
0609
Each compartment has capacity for:
•
Three, 12˝ x 20˝ x 2
1
⁄2˝ or six, 12˝ x 20˝ x 1˝ deep
Cafeteria Pans.
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards
whether untreated or pre-treated, based upon 10 hours
of use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million
TOTAL ALKALINITY less than 20 parts per million
SILICA less than 13 parts per million
H FACTOR greater than 7.5
p
CHLORINE less than 30 parts per million
Consult a local water treatment specialist for an on site
water analysis for recommendations concerning steam
generator feed water treatment (if required), in order to
remove or reduce harmful concentrations of minerals.
The use of highly mineralized water will mean that more
frequent servicing of the steam generator will be
necessary. The fact that a water supply is potable is not
proof that it will be suitable for the generator.
ELECTRIC
KW Volts Watts Ph Amps Wire
24 208 21,500 1 103.4 2
220 24,000 1 109.1 2
240 24,000 1 100.0 2
440 20,200 1 45.9 2
480 24,000 1 50.0 2
208 21,500 3 59.7 3
220 24,000 3 63.1 3
240 24,000 3 57.8 3
440 20,200 3 26.5 3
480 24,000 3 28.9 3
600 24,000 3 23.1 3
360 21,500 3 34.5 4
380 24,000 3 36.5 4
415 24,000 3 33.4 4
WATER DRAINAGE CLEARANCE
1/4˝ NPT
Cold Water Inlet
35 psi minimum
60 psi maximum
The Floor Drain must be located
outside the confines of the
equipment base.
1 1/2˝ I.P.S. common drain.
Do not connect other units to this drain.
Do not use PVC pipe for drain.
KW Volts Watts Ph Amps Wire
36 208 32,200 3 89.5 3
220 36,000 3 94.6 3
240 36,000 3 86.7 3
440 30,200 3 39.7 3
480 36,000 3 43.4 3
600 36,000 3 34.7 3
360 32,200 3 51.7 4
380 36,000 3 54.8 4
415 36,000 3 50.1 4
48 208 42,900 3 119.2 3
220 48,000 3 126.1 3
240 48,000 3 115.6 3
440 40,300 3 52.9 3
480 48,000 3 57.8 3
600 48,000 3 46.2 3
360 42,900 3 68.9 4
380 48,000 3 73.0 4
415 48,000 3 66.9 4
D
Right - 3”, Left - 3”, Rear - 3”
(12” on control side if
adjoining wall or equipment
is over 30” high for service
acess)
Contact factory for
variances to clearances.
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL, NSF and CSA.
(NOT TO SCALE)