MODULAR BASES
MODULAR CABINET BASE
STEAM COIL STEAM GENERATOR
24" (600 MM) or 36" (900 MM) WIDE BASE
Cleveland Standard Features
II
Type 430 Stainless Steel exterior enclosure and Table Top
II
6" Stainless Steel Legs with level adjustment with flanged
feet
II
Solid State steam generator Water Level Controls
II
Low Water Power Cut-off
II
Pressure Limit Controls with 15 psi Safety Valve
II
Major Components serviceable from the front of unit
II
Steam Generator empties under pressure (blowdown)
automatically upon each Shut-Down. Automatic Water
Refill on Start-Up
II
Separate "Start/Reset" Illuminated switch controls, plus
Pressure Gauge
II
Steam Generator Drain incorporates Water Cooling and
"Jet/Rinsing"
II
Steam Generator is complete with Access Hole/Cover Plate
and Sight Glass Gauge
II
Secondary Low Water Cut-Off, factory installed (CALS)
(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN.
MT. NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY,
Wash. DC)
II
Standard voltage is 115 volt, 60 Hz, single phase
II
Single cold water connection (no hot water required)
Options & Accessories
Ë Voltages for controls other than standard
Ë Stainless Steel Base Frame (FSS)
MODEL: 24-SM
Short Form Specifications
Shall be CLEVELAND, Modular Cabinet Base with Steam Coil Steam
Generator Model _____ -SM. Type 430 Stainless Steel exterior enclosure,
Table Top and four Level Adjustable Legs. Console mounted controls,
Pressure Gauge and "Start/Reset" control switches.Solid State Water Level
Steam Generator Controls. Steam Generator drains under pressure (blowdown) after each Shut-Down, Automatic Water Fill on Start-Up. 15 psi Safety
Valve.
SECT. VII PAGE 5
0609
WATER QUALITY REQUIREMENT
he recommended minimum water quality standards
T
whether untreated or pre-treated, based upon 10 hours of
use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million
TOTAL ALKALINITY less than 20 parts per million
SILICA less than 13 parts per million
pH FACTOR greater than 7.5
CHLORINE less than 30 parts per million
Consult a local water treatment specialist for an on site
water analysis for recommendations concerning steam
generator feed water treatment (if required), in order to
remove or reduce harmful concentrations of minerals. The
use of highly mineralized water will mean that more
frequent servicing of the steam generator will be necessary.
The fact that a water supply is potable is not proof that it
will be suitable for the generator.
Right - 3”, Left - 3”, Rear - 3”
100 watts
3/4” IPS. Do not connect
to common drain.
Do not use PVC pipe for drain.
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, NSF and UL.
(12” on control side if
adjoining wall or equipment is
over 30” high for service
access)
Contact factory for
variances to clearances.
(NOT TO SCALE)
SECT. VII PAGE 6
0609