Cleveland 24-GM-K6-200 User Manual

Cleveland Range LLC.
1333 East 179th St., Cleveland, Ohio, U.S.A. 44110 Ph: 1-216-481-4900 Fx: 1-216-481-3782 Visit our Web Site at www.clevelandrange.com
MODELS: 24-GM-K6-200
36-GM-K66-20036-GM-K66-300
ITEM NUMBER __________________________________________ JOB NAME / NUMBER __________________________________
Cleveland Standard Features
Factory assembled Kettle/Steam Generator NickleGard Base combination with one or two,6 gallon kettles with 200M BTU Gas-Fired Steam Generator
Solid State steam generator Water Level Controls
Low Water Safety Cut-Off
Pressure Limit Controls with 15 psi Safety Valve
Type 430 Stainless Steel exterior enclosure, and table top
(with Drain Trough which has 1.50" diameter male drain), #4 exterior finish
Type 304 Stainless kettle(s), #4 exterior finish
Separate "Start/Reset" Illuminated Switch Controls, plus
Pressure Gauge
Solid State Electronic Spark Ignition for energy savings
Major components serviceable from the front of the unit
6 gallon kettle(s) are 2/3 Steam Jacketed and include Lift
off Cover(s)
Hot and Cold Water Faucet with Swing Spout
Kettle(s) have 50 psi Steam Jacket Rating, 50 psi chrome
plated Safety Valve(s) and Manual Tilting, balanced design
Tilt Handles can be mounted on either side
Steam Generator empties under pressure (blowdown)
automatically upon each Shut-Down.Automatic Water Refill on Start-Up
Standard voltage for controls is 115 volt, 60 Hz, single phase
Adjustable Flanged Feet (FF-A)
Options & Accessories
Power Take-Off Kit (GPTO)Secondary Low Water Cut-Off, factory installed (CALG)
(Required for AZ. AR. CA. CO. CT.DE.FL. GA. HI. IL. IA. KS. MD.MA. MI. MN. MT.NE.NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA.WV., Buffalo, NY, Wash.DC)
Gas, other than naturalType 316 Stainless Steel kettle interior for high acid food
products (316)
Food Strainers (FS)Stainless Steel Base Frame (FSS)300,000 BTU Gas-Fired Boiler with NickelguardBoiler Descaling Pump Kit (107142)
Shall be CLEVELAND, Modular Cabinet Base with one or two, 6 gallon kettle(s), Model _____ GM-K _____ -200, 200M Nickelguard BTU Gas-Fired Steam Generator, type 430 Stainless Steel exterior enclosure, Table Top, Back Splash and 4 level adjustable feet. 2/3 Steam Jacketed type 304 Stainless Steel kettle(s) with 50 psi Steam Jacket Rating; needle type Steam Control Valve on each kettle. Console mounted Controls, Pressure Gauge and Illuminated "Start/Reset" Control Switches. Solid State Water Level Steam Generator Controls and Electronic Spark Ignition. Steam Generator drains under pressure (blowdown) after each Shut-Down with Automatic Water Refill on Start-Up. 15 psi Safety Valve
Short Form Specifications
SECT. VII PAGE 21
0402
MODULAR BASE WITH KETTLE(S)
200M BTU GAS-FIRED STEAM GENERATOR with NICKELGUARD™ ONE or TWO, 6 GALLON KETTLE(S) CABINET BASE: 24" (600MM) or 36" (900MM) WIDE
1
0
0
%
5
Y
e
a
r
B
o
i
l
e
r
W
a
r
r
a
n
t
y
N
i
c
k
e
l
G
u
a
r
d
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL/NSF#4 and CSA (AGA, CGA).
(NOT TO SCALE)
SECT. VII PAGE 22
0402
Litho in U.S.A.
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards whether untreated or pre-treated, based upon 10 hours of use per day, and a Daily Blowdown, are as follows:
TOT AL DISSOLVED SOLIDS less than 60 parts per million TOT AL ALKALINITY less than 20 parts per million SILICA less than 13 parts per million pH FACTOR greater than 7.5 CHLORINE less than 30 parts per million
Consult a local water treatment specialist for an on site water analysis for recommendations concerning steam generator feed water treatment (if required), in order to remove or reduce harmful concentrations of minerals.The use of highly mineralized water will mean that more frequent servicing of the steam generator will be necessary.The fact that a water supply is potable is not proof that it will be suitable for the generator.
CAPACITIES
(in 4 oz. servings)
(Other sizes may be calculated.)
6 gallon / 23 liters ..... 160 per kettle
Right - 6”, Left - 6”, Rear - 6” (12” on control side if adjoining
wall or equipment is over 30” high for service access)
For use in non-combustible locations.
Contact factory for variances to clearances.