Cleveland
™
P
roject ________________________________
Item __________________________________
Quantity _______________________________
F
CSI Section ____________________________
A
pproval _______________________________
D
ate __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
1
0
0
%
5
Y
e
a
r
B
o
i
l
e
r
W
a
r
r
a
n
t
y
N
i
c
k
e
l
G
u
a
r
d
™
MODULAR BASES
MODULAR BASE WITH KETTLE
200M GAS-FIRED STEAM GENERATOR with NICKELGUARD™
ONE 10 GALLON KETTLE
CABINET BASE: 24" (600MM) WIDE
Cleveland Standard Features
II
Factory assembled Kettle/Steam Generator NickelGuard Base
combination with one 10 gallon kettle with 200M BTU GasFired Steam Generator
II
Solid State steam generator Water Level Controls
II
Low Water Safety Cut-Off
II
Pressure Limit Controls with 15 psi Safety Valve
II
Type 430 Stainless Steel exterior enclosure, and type 304
Stainless Steel table top (with Drain Trough which has 1.50"
diameter male drain), #4 exterior finish
II
Type 304 Stainless kettles, #4 exterior finish
II
Separate "Start/Reset" Illuminated Switch Controls, plus
Pressure Gauge
II
Solid State Electronic Spark Ignition for energy savings
II
Major components serviceable from the front of the unit
II
10 gallon kettle is 2/3 Steam Jacketed and includes a
Lift-off Cover and Splash Guard
II
Hot and Cold Water Faucet with Swing Spout
II
Kettle has a 50 psi Steam Jacket Rating, 50 psi chrome
plated Safety Valve and Manual Tilting, balanced design
II
Tilt Handle can be mounted on right side
II
Steam Generator empties under pressure (blowdown)
automatically upon each Shut-Down, Automatic Water
Refill on Start-Up
II
Standard voltage for controls is 115 volt, 60 Hz,
single phase
II
6" Stainless Steel Legs with Adjustable Flanged Feet (FF-A)
II
Secondary Low Water Cut-Off, factory installed (CALG)
(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN. MT.
NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY, Wash. DC)
MODELS: 24-GM-K10-200
Short Form Specifications
Shall be CLEVELAND, Modular Cabinet Base with one 10 gallon kettle, Model
24-GM-K10-200, 200M BTU Nickelguard Gas-Fired Steam Generator, type
430 Stainless Steel exterior enclosure, type 304 Stainless Steel Table Top,
Back Splash and 4 level adjustable feet. 2/3 Steam Jacketed type 304
Stainless Steel kettle with 50 psi Steam Jacket Rating. Console mounted
Controls, Pressure Gauge and Illuminated "Start/Reset" Control Switches.
Solid State Water Level Steam Generator Controls and Electronic Spark
Ignition. Steam Generator drains under pressure (blowdown) after each ShutDown with Automatic Water Refill on Start-Up. 15 psi Safety Valve
Options & Accessories
Ë Power Take-Off Kit (GPTO)
Ë Gas, other than natural
Ë Type 316 Stainless Steel kettle interior for high acid food
products (316)
Ë Food Strainer (FS)
Ë Stainless Steel Base Frame (FSS)
Ë Boiler Descaling Pump Kit (107142)
SECT. VII PAGE 33
0609
H
C1
C1
D
D
C2
H
C2
GAS FLUE
28.31"
719mm
2
.03"
5
2mm
5.00"
127mm
1
9.00"
4
82mm
3.50"
89mm
2
4.00"
610mm
25.88"
6
57mm
29.56"
751mm
3
7.00"
9
40mm
3.00"
76mm
6.12"
155mm
11.81"
300mm
17.84"
453mm
1
9.00"
483mm
23.62"
600mm
5.38"
137mm
1.38"
35mm
6.00"
152mm
7.50"
191mm
9.00"
229mm
12.50"
318mm
30.00"
762mm
62.00"
1575mm
20.40"
518mm
1.61"
41mm
1.61"
41mm
WATER QUALITY
REQUIREMENT
The recommended minimum water quality
standards whether untreated or pretreated, based upon 10 hours of use per
day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS
less than 60 parts per million
TOTAL ALKALINITY
less than 20 parts per million
SILICA
less than 13 parts per million
pH FACTOR
greater than 7.5
CHLORINE
less than 30 parts per million
Consult a local water treatment specialist for
an on site water analysis for recommendations concerning steam generator feed water
treatment (if required), in order to remove or
reduce harmful concentrations of minerals.
The use of highly mineralized water will
mean that more frequent servicing of the
steam generator will be necessary. The fact
that a water supply is potable is not proof
that it will be suitable for the generator.
CAPACITY: (in 4 oz. servings,
other sizes may be calculated.)
10 Gallon / 36 liters . . . . . . . 320 servings
ELECTRIC
50 watts for generator
115 V-1 PH
** Do not connect to GFI outlet. See
note below.
WATER
C1: 1/4" IPS Cold water for boiler
C2: 3/8" NPT Cold water for faucet
C2: 3/8" NPT Hot water for faucet
DRAIN
GAS
NATURAL
3/4" IPS for 200,000
1.00" IPS for 300,000
Supply Pressure
4.00" W.C. Minimum
14.00" W.C. Maximum
NOTES:
**DO NOT CONNECT TO GFI OUTLET. CLEVELAND RANGE RECOMMENDS GAS FIRED 120 VOLT STEAMERS BE HARD WIRED DIRECTLY TO ELECTRICAL SYSTEM.
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL/NSF#4 and CSA (AGA, CGA).
PROPANE
3/4" IPS for 200,000
1.00" IPS for 300,000
Supply Pressure
12.00" W.C. Minimum
14.00" W.C. Maximum
1 1/2" IPS Common Drain
The floor drain must be
located outside the confines
of the equipment.
Do not connect to any other drain.
CLEARANCES
Right: 6.00"
Left: 6.00"
Rear: 6.00"
(NOT TO SCALE)
SECT. VII PAGE 34