Cleveland
™
P
roject ________________________________
Item __________________________________
Quantity _______________________________
F
CSI Section ____________________________
A
pproval _______________________________
D
ate __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
1
0
0
%
5
Y
e
a
r
B
o
i
l
e
r
W
a
r
r
a
n
t
y
N
i
c
k
e
l
G
u
a
r
d
™
MODULAR BASES
MODULAR CABINET BASE
GAS-FIRED STEAM GENERATOR with NICKELGUARD™
200, 250 or 300M BTU
24" (600MM) or 36" (900MM) WIDE BASE
Cleveland Standard Features
II
Type 430 Stainless Steel exterior enclosure, Back Splash
and Table Top with #4 finish
II
HInged Cabinet Door
II
6" Stainless Steel Legs with level adjustment and flanged
feet
II
Solid State steam generator Water Level Controls
II
Low Water Safety Cut-off
II
Pressure Limit Controls with 15 psi Safety Valve
II
Solid State Electronic Spark Ignition for energy savings
II
Major components serviceable from the front of unit
II
Nickelguard Steam Generator empties under pressure
(blowdown) automatically upon each Shut-Down. Automatic
Water refill on Start-Up.
II
Separate "Start/Reset" Illuminated switch controls, plus
pressure Gauge
II
Steam Generator Drain incorporates Water Cooling
and "Jet Rinsing"
II
Insulated steam generator reduces heat loss to work area
II
Gas Pressure Regulator
II
Steam Generator is complete with Access Hole/Cover Plate
and Sight Glass Gauge
II
Standard voltage for controls is 115 volt, 60 Hz, single
phase
II
Single Cold water connection (no hot water required)
II
Secondary Low Water Cut-Off, factory installed (CALG)
(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN. MT.
NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY, Wash. DC)
MODELS: 24-GM-200 36-GM-300
Short Form Specifications
Shall be CLEVELAND, Modular Cabinet Base, Model _____ -GM _____ M,
Nickelguard, BTU gas generator, type 304 Stainless Steel Exterior enclosure, Table Top and 6" Level Adjustable Legs. Console mounted controls,
Pressure Gauge and Illuminated "Start/Reset" control switches. Solid State
Water Level Steam Generator Controls. Steam Generator drains under pressure (blow-down) after each Shut-Down, Automatic Water Fill on Start-Up. 15
psi Safety Valve.
Options & Accessories
Ë Power Take-Off Kit (GPTO)
Ë Gas, other than natural
Ë Insulated Flue for island installation
Ë Stainless Steel Base Frame (SSF)
Ë Boiler Descaling Pump Kit (107142)
SECT. VII PAGE 3
0609
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards
whether untreated or pre-treated, based upon 10 hours of
se per day, and a Daily Blowdown, are as follows:
u
TOTAL DISSOLVED SOLIDS less than 60 parts per million
TOTAL ALKALINITY less than 20 parts per million
SILICA less than 13 parts per million
pH FACTOR greater than 7.5
CHLORINE less than 30 parts per million
Consult a local water treatment specialist for an on site
water analysis for recommendations concerning steam generator feed water treatment (if required), in order to remove
or reduce harmful concentrations of minerals. The use of
highly mineralized water will mean that more
frequent servicing of the steam generator will be necessary.
The fact that a water supply is potable is not proof that it
ill be suitable for the generator.
w
1 1/2” IPS common drain.
Do not connect other units
to this drain.
5.0 Amps
** Do not connect to GFI
outlet. See note below.
NOTES:
**DO NOT CONNECT TO GFI OUTLET. CLEVELAND RANGE RECOMMENDS GAS FIRED 120 VOLT STEAMERS BE HARD WIRED DIRECTLY TO ELECTRICAL SYSTEM.
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, NSF and CSA (AGA, CGA).
Do not use PVC pipe for
drain.
Right - 6”, Left - 6”, Rear - 6”
(12” on control side if adjoining
wall or equipment is over 30”
high for service access)
For use in non-combustible
locations.
Contact factory for
variances to clearances.
(NOT TO SCALE)
SECT. VII PAGE 4
0609
Litho in U.S.A.