MODULAR BASES
MODULAR BASE WITH KETTLE(S)
24 KW ELECTRIC STEAM GENERATOR ONE or TWO 6 GALLON KETTLE(S) CABINET BASE: 24" (600MM) or 36" (900MM) WIDE
Cleveland Standard Features
II
Factory assembled Kettle/Steam Generator Base
combination with one or two, 6 gallon kettles with 24 KW Electric Steam Generator
II
Solid State steam generator Water Level Controls
II
Low Water Safety Cut-off
II
Pressure Limit Controls with 15 psi Safety Valve
II
Type 430 Stainless Steel exterior enclosure, and table top (with Drain Trough which has 1.50" diameter male drain), #4 exterior finish
II
Type 304 Stainless kettle(s), #4 exterior finish
II
Separate Start/Rest Illuminated Switch Controls, plus Pressure Gauge
II
Major components serviceable from the front of the unit
II
6 gallon kettle(s) are 2/3 Steam Jacket rating, and include Lift-off Covers
II
Hot and Cold Water Faucet with Swing Spout
II
Kettle(s) have 50 psi chrome plated Safety Valve(s) and Manual Tilting balanced design
II
Tilt Handles can be mounted on either side
II
Steam Generator empties under pressure (blowdown) automatically upon each Shut-Down. Automatic Water Refill on Start-Up
II
"Clear access" Lift-Off Front Panel
Ë Secondary Low Water Cut-Off, factory installed (CALE)
(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN. MT. NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY, Wash. DC)
II
Standard voltage is 208volt, 60 Hz, 3 Phase, 3 Wire
II
Adjustable Flanged Feet (FF-A)
MODELS: 24-EM-K6-24
36-EM-K36-2436-EM-K66-24
Short Form Specifications
Shall be CLEVELAND, Modular Cabinet Base with one or two, 6 gallon ket­tle(s),Model _____ -EM-K _____ -24,with 24KW Electric Steam Generator; type 430 Stainless Steel exterior enclosure, table top and 4 level adjustable feet. 2/3 Steam Jacketed, type 304 Stainless Steel kettle(s) with 50 psi Steam Jacket Rating; needle type Steam Control Valve on each kettle. Console mounted Controls, Pressure Gauge and Illuminated "Start/Reset" Control Switches. Solid State Water Level Steam Generator Controls. Steam Generator drains under pressure (blowdown) after each Shut-Down with Automatic Water Refill on Start-Up. 15 psi Safety Valve.
Options & Accessories
Ë Power Take-Off Kit (EPTO)
Ë Voltages other than standard
Ë Type 316 Stainless Steel kettle interior for high acid food
products (316)
Ë Food Strainers (FS)
Ë Stainless Steel Base Frame (FSS)
Ë Boiler Descaling Pump Kit (107142)
SECT. VII PAGE 21
0609
C
APACITIES
in 4 oz. servings)
(
(Other sizes may be calculated.)
6 gallon / 23 liters ..... 160 per kettle
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards whether untreated or pre-treated, based upon 10 hours of use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million TOTAL ALKALINITY less than 20 parts per million SILICA less than 13 parts per million pH FACTOR greater than 7.5 CHLORINE less than 30 parts per million
Consult a local water treatment specialist for an on site water analysis for recommendations concerning steam generator feed water treatment (if required), in order to remove or reduce harmful concentrations of minerals. The use of highly mineralized water will mean that more frequent servicing of the steam generator will be necessary. The fact that a water
upply is potable is not proof that it will be suitable for the generator.
s
1 1/2” IPS common drain.
Do not connect other units to this drain.
The Floor Drain must be located outside the con­fines of the equipment.
Do not use PVC pipe for drain.
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are U.L., NSF, CGA, CSA, ETL and others.
Right - 3”, Left - 3”, Rear - 3”
(12” on control side if adjoin­ing wall or equipment is over 30” high for service access)
Contact factory for variances to clearances.
(NOT TO SCALE)