Cleveland 24-CGP-10 User Manual

Cleveland
P
roject ________________________________
Item __________________________________
Quantity _______________________________
F
A
pproval _______________________________
D
ate __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
STEAMCRAFT®GENERATOR STYLE HIGH SPEED CONVECTION STEAMERS
SteamCraft®Power 10
TWO COMPARTMENT FLOOR MODEL DESIGN GAS STEAM GENERATORS 240M BTU,
Cleveland Standard Features
II
Pressureless cooking permits doors to be opened during oper­ation. Capacity for up to ten 12" x 20" x 2 pans, five each compartment.
II
Exclusive PowerPak Gas Steam Generator:
High Efficiency Forced Air (Power Burner) Gas Fired Boiler has 240,000 Btu's Input, produces 180 Ibs of steam per hour. 10-12 PSI operating generator pressure. Steam generator is equipped with a High-Limit Pressure Safety Switch, 15 psi Safety Valve and a Secondary Low Water Shut Off Safety standard. Fully insulated rear mounted steam generator. Gas Pressure Regulator and Control Valve included standard.
Boiler Descaling Port Connection: Inlet and Outlet descal-
II
ing port connections for use with the Descaling Pump
II
Instant Steam Stand By Mode: Holds generator at a steaming temperature. Allows unit to start steaming instantly.
II
Durable 14 Gauge, Stainless Steel Construction: For compartment door, cavity and cabinet frame.
II
Two 60 Mechanical Timers with ON/OFF Main Power Switch
with a Heat On, Low Water Indicator Lights and High Temperature Safety Light and Shut-off (Reset Light).
II
Main Power On/Off Switch: Controls the electric power and automatically fills the generator with water. A separate Steam Switch ignites the burners via a fully automatic Electronic (pilotless) Spark Ignition.
II
Exclusive Steam Cooking Distribution System:
Exclusive Brass Steam Jets produce a high velocity convection steam without fans. Coved Corner design in cooking compartment distributes heat evenly, easy to clean. Creased top & bottom enhance drainage. Cold Water Condenser for each compartment maintains a dry steam. Fully insulated cooking compartment for thermal efficiency. Removable Stainless Steel Slide Racks. Reversible Door Gasket.
II
Automatic Boiler Drain: Contains a “Water Jet” Spray Rinse Drain Cleaning Cycle to keep drain clear.
II
Exclusive Automatic Float for Water Level Control:
Separate from the generator for easy access, contains a high velocity rinse cycle to eliminate mineral buildup.
II
Exclusive “Cool to the Touch” Two-Piece Compartment Door Design: Free floating inner door with reversible gasket
provides an air tight seal. Stainless Steel Slam/Latch Door mechanism for reliability.
II
Condensate Drip Trough: Provided under lower compartment door to collect condensate.
II
Left Hand Door Hinging: Compartment Doors hinged on the left, controls on the right.
II
NSF Certified 6˝ Stainless Steel Legs with adjustable flanged feet for a one inch level adjustment.
II
CSD-1 Compliant
24" WIDE MODULAR DESIGN
1
2" deep Cafeteria
MODEL: 24-CGP-10
Short Form Specifications
Shall be CLEVELAND, Floor Model Steamer, Model 24-CGP-10. Single, large capacity Gas-fired Pressure Steam Generator, 240M BTU input. Exclusive Automatic Water Level Float design. Steam Generator with Automatic Water Fill on start up, Automatic Generator Blowdown, Electronic Spark Ignition and Generator Standby for instant steam. Choice of Compartment Controls, Manual By Pass Operation Mode. Exclusive Cold Water Condenser design.
Options & Accessories
Ë Boiler Descaling Pump Kit (107142) Ë Right hand Door Hinging, Controls on Right (DHR) Ë Electronic Timer with Compensating Load Feature (ETC) Ë ON/OFF Steam Switch for compartment controls (MC) Ë Power Take Off Kit (GPTO-1O) Ë Kettle Interconnecting Kit (IMK-) Ë Compartment Door Steam Shut Off Switch (SCS) Ë Cafeteria Pans in depths of 1", 2 Ë Type of gas other than natural Ë Dissolve
markings (106174)
Ë Water Filters Ë Correctional Packages
®
Descale Solution, 6 one gallon container w/quart
SteamCraftPower 10
1
⁄2", 4" and 6"
, two compartments,
SECT. IV PAGE 19
0609
C1 C2
C1 C2
C1
C1 C2
C1
C2
Each Compartment has capacity for:
• Five, 12˝ x 20˝ x 2
1
2˝ deep
Cafeteria Pans.
WATER QUALITY REQUIREMENTS
he quality of water varies
T greatly from region to region. Steam equipment generators must be drained daily and chemically descaled periodically to ensure proper operation. To minimize service problems caused by the accumulation of minerals and chemicals in water review the following quality guidelines with a local water treatment specialist. Inlet water that is beyond these specified guidelines should be treated to achieve these acceptable limits. Total Dissolved Solids less than 60 ppm, Alkalinity less than 20 ppm, Silica less than 13 ppm, pH factor greater than 7.5, Chlorine less than 30 ppm.
TOTAL CAPACITY (2 Compartments)
10 — 12˝ x 20˝ x 21⁄2˝ Cafeteria Pans or 20 — 12˝ x 20˝ x 1˝ Cafeteria Pans or
26 — 12˝ x 20˝ x 4˝ Cafeteria Pans
GAS COLD WATER DRAINAGE
240,000 BTU - Piping 11⁄4˝ IPS Line Size, 3⁄4˝ Connection
SUPPLY PRESSURE
NATURAL PROPANE
4.00˝ W.C. minimum 12.00˝ W.C. minimum
14.00˝ W.C. maximum 14.00˝ W.C. maximum
Manufacturer must be notified if unit will be used above 2,000 ft. altitude.
NOTES:
**DO NOT CONNECT TO GFI OUTLET. CLEVELAND RANGE RECOMMENDS GAS FIRED 120 VOLT STEAMERS BE HARD WIRED DIRECTLY TO ELECTRICAL SYSTEM. Cleveland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL/NSF#4 and CSA (AGA, CGA).
Electrical Supply Drain: 1.50˝ Dia. Flue Gas Exhaust from Boiler
A
B
Cold Water Supply for Condenser 3/8˝ Dia. NPT Gas Supply .75˝ Dia. Flue Diverter
Cold Water Supply for Generator and Water Injection. Power Take Off Connection
C
3/8˝ Dia. NPT (for water treatment conn.) 3/8˝ Dia. IPS Unit comes with a 50 Mesh Water Strainer (installation required)
ELECTRIC
115V - 1 Phase
1 Fan & Controls - 150 Watts
** Do not connect to GFI outlet. See note below.
UTILITY CONNECTIONS
D
F
35 psi minimum 60 psi maximum
3
8˝ Dia. NPT for
Generator
3
8˝ Dia. NPT for
Condenser
11⁄2˝ dia.
Do not connect other units to this drain
Drain must not be located beneath the steamer itself. Preferred floor drain location should be a minimum distance (from the unit) of at least 12” from the left side, 12" from the right side, 6” from the front and 6" from the rear
Do not use PVC pipe
G
H
I
D
CLEARANCE
Right - 3”, Left - 3”, Rear - 3”
(12” on control side if adjoining wall or equip­ment is over 30” high for service access)
Contact factory for variances to clearances.
SCALE .75" = 1'
SECT. IV PAGE 20
0609
Litho in U.S.A.