Cleveland 24CGA6.2SES User Manual

Cleveland
P
roject ________________________________
Item __________________________________
Quantity _______________________________
F
A
pproval _______________________________
D
ate __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
Technology
T M
S
t
e
a
m
S
a
v
e
r
HIGH EFFICIENCY GENERATOR STYLE GAS CONVECTION STEAMERS
Gemini 6 SST
TWIN, INDEPENDENT GAS-FIRED GENERATOR with SteamSaver™ TECHNOLOGY and ENERGY STAR APPROVED
Cleveland Standard Features
I
I
Exclusive SteamSaverTechnology (SST) is an energy and
ater saving compartment design that automatically controls
w steam production based on the type and volume of food being prepared. The Gemini SST with its high efficiency forced air gas generator design allows enough steam to be produced for proper cooking times while minimizing energy use and saving water
II
54.5” (1385mm) height to top of upper compartment (lower height makes maintenance easier by lowering the descal­ing ports)
II
Each compartment has cooking capacity for 3 each 12˝ x 20˝ x 2
II
Doors hinged left and the controls on the right
II
High efficiency independent Power Burner Steam Generators 50,000 BTU's for each compartment
II
Each steam-cooking compartment is independently operated and controlled by a separate stainless steel steam generator, gas valve, Power On/Off Control Levers and a Exclusive, Remote Probe-Type Water Level Control
II
Easy Access Cleaning Port: Each generator has a deliming port located on the outside, top of the unit
II
Generator Cleaning Light for each compartment warns the oper­ator to delime generator
II
Generator Steam Standby Mode: Holds generator at a steaming temperature, allows unit to start cooking quickly
II
Each compartment has one, 60-Minute Electro-Mechanical Timer with "SureCook" load compensating feature. Manual Bypass Switch for constant steaming.
II
Durable 14 Gauge, 304 Stainless Steel construction for compartment door, cooking cavity and steam generator
II
Exclusive Gemini Drain/Power Control System:
Manual 1/2 inch "Ball Valve" type drain that controls main power On/Off and automatically fills generator (located on the control panel)
II
Exclusive Brass Steam Jets distribute steam evenly throughout cooking compartment
II
Easy, Front -Access Generator Controls comes with a pullout drawer for simple servicing of unit
II
6˝ Stainless Steel Adjustable Legs with Flanged Feet
II
Approvals: CSA (formerly AGA) U.L/NSF#4 and Energy Star
II
Compartment Steam Shut-Off Switch when compartment door is opened
1
2˝ Steam Table Pans
MODEL: 24CGA6.2SES
Short Form Specifications
Cleveland Gemini 6 SST Model 24CGA6.2SES 54.5" high, Two compartment steamer
approved, partment.
sating feature. Gas valve and water level control system. Exclusive remote probe-type water level controls. Exclusive Brass “Steam Jet” distribution system. Two-piece free-floating compartment door. 14 gauge stainless steel cavity and door. Pullout service drawer for controls and Gemini Drain/Power Control System.
Independent steam generators "SureCook" electro mechanical timer with load compen-
Options & Accessories
Ë Electronic Timer with Compensating Feature (ETC)
Ë On/Off Steam Switch Controls, no timer (MC)
Ë Dissolve
markings (106174)
Ë Water Filters (9797-21 KleenSteam II)
®
Descale Solution, 6 one gallon container w/quart
with SteamSaver™ Technology and Energy Star
, 50,000 BTU's input per com-
SECT. IV PAGE 11B
0609
20.63
33.13
4.87
7.75
10.44
5.00
12.76
1
5.06
17.43
59.21
1
3.25
10.00
2
.06
2
0.88
5.00
4.75
13.88
20.36
23.37
A GAS B ELECTRIC COLD WATER CLEARANCE C DRAINAGE
1-1/4" IPS line size, 3/4" connection
115V-1Phase, 60 Hz. 35 PSI minimum RIGHT = 12.00" for service
2" dia. OD
BTU 2 Fans & controls 60 psi maximum SIDES = 3.00”
50,000
each
150 watts each
(1) 1/2" dia. IPS for
D
Condenser
REAR = 3.00” Do not connect other units to
this drain.
Generator
FRONT = 24.00” Drain must be free air vented.
NATURAL
Piping 3/4" NPT
Supply pressure
4.50" W.C. Min.
14.00” W.C. Max.
PROPANE
Piping 3/4" NPT
Supply pressure
11.00" W.C. Min.
14.00” W.C. Max. 100,000 total
(1) 3/8" dia. IPS for
E
Generator
elba eb tsum gnibmulp niarD
to withstand 140°F (60°C).
The drain must not be located beneath the steamer itself.
Manufacturer must be notified if unit will be used above 2,000 feet
WATER QUALITY REQUIREMENTS
The quality of water varies greatly from region to region. Steam equipment generators must be drained daily and chem­ically descaled periodically to ensure proper operation. To min-
mize service problems caused
i by the accumulation of minerals and chemicals in water review the following quality guidelines with a local water treatment spe­cialist. Inlet water that is beyond these specified guidelines should be treated to achieve these acceptable limits. Total Dissolved Solids less than 60 ppm, Alkalinity less than 20 ppm, Silica less than 13 ppm, pH factor greater than 7.5, Chlorine less than 30 ppm.
Each Compartment has Capacity for:
• Three 21⁄2˝ x 12˝ x 20˝ Steam Table Pans
• Six 1˝ x 12˝ x 20˝ Steam Table Pans
• Two 4˝ x 12˝ x 20˝ Steam Table Pans
Energy Star Data
(Heavy Load #3 Red Skin Potatoes)
Cooking Time (min) 25.8 3.6 Preheat Energy 16,860 15,587 (btu/kw) h Idle Energy Rate 3,711 3,709 (btu/kw) h Potato Production 187 122 (lbs/h)
Cooking Efficiency % 44.7% 39.3% Energy Consumption 127.9 99.6 (Btu//kW) h Cooking Energy Rate 47,683 37,657 (Btu//kW) h
Use the above information to access the Foodservice Technology Center Life-Cycle and Energy Cost Calculator @
http://www.fishnick.com/saveenergy/tools/calculators/
24CGA10.2ES 24CGA6.2SES
NOTES:
**DO NOT CONNECT TO GFI OUTLET. CLEVELAND RANGE RECOMMENDS GAS FIRED 120 VOLT STEAMERS BE HARD WIRED DIRECTLY TO ELECTRICAL SYSTEM. Cleveland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are UL/NSF#4 and CSA (AGA, CGA).
(NOT TO SCALE)
SECT. IV PAGE 12B
0609
Litho in U.S.A.
Loading...