Cleveland 24-CGA-6 User Manual

Cleveland Range LLC.
1333 East 179th St., Cleveland, Ohio, U.S.A. 44110 Ph: 1-216-481-4900 Fx: 1-216-481-3782 Visit our Web Site at www.clevelandrange.com
MODEL: 24-CGA-6
ITEM NUMBER __________________________________________ JOB NAME / NUMBER __________________________________
Each Compartment has cooking capacity for 3 each
12˝ x 20˝ x 2
1
2
˝ Steam Table Pans
Two compartments for convection steam cooking and one
compartment for storage.Doors hinged left and the controls on the right
75% efficient independent Power Burner Steam Generators
35,000 BTUs each
Each steam-cooking compartment is independently operated
and controlled by a separate stainless steel steam generator, gas valve, Power On/Off Control Levers and a Exclusive, Remote Probe-Type Water Level Control
Easy Access Cleaning Port: Each generator has a deliming
port located on the outside, top of the unit
Generator Cleaning Light for each compartment warns the
operator to delime generator
Instant Steam Standby Mode:Holds generator at a steaming
temperature, allows unit to start cooking instantly
Each compartment has one, 60-Minute Mechanical Timer and
a Manual Bypass Switch for constant steaming
Durable 14 Gauge, 304 Stainless Steel construction for
compartment door, cooking cavity and steam generator
Exclusiv
e Gemini Drain/Power Control System:
Manual 1/2 inch "Ball Valve" type drain that controls main power On/Off, and automatically fills generator
Exclusive Brass Steam Jets distribute steam even throughout
cooking compartment
Easy, Front -Access Generator Controls comes with a pullout
drawer for simple servicing of unit
6˝ Stainless Steel Adjustable Legs with Flanged Feet
Approvals:AGA, NSF
Compartment Steam Shut-Off Switch (SCS)
Options & Accessories
Electronic Timer with Compensating Feature (ETC)On/Off Steam Switch Controls, no timer (MC) Propane Gas (PG)Dissolve
®
Descale Solution, 6 one gallon container w/quart
markings (106174)
Water Filters
Cleveland
SteamCraftGemini
TM
Model 24CGA6, Two compart­ment steamer, one compartment storage. Independent steam generator, gas valve and water level control system. Exclusive remote probe-type water level controls. Exclusive Brass “Steam Jet” distribution system. Two-piece free-floating compartment door. 14 gauge stainless steel cavity and door. Pullout service drawer for controls and Gemini Drain/Power Control System.
Short Form Specifications
SECT. IV PAGE 11
0402
SteamCraft®GeminiTM6
PRESSURELESS STEAMER TWIN, INDEPENDENT GAS-FIRED GENERATORS
GAS ELECTRIC COLD WA TER CLEARANCE DRAINAGE
11⁄4˝ IPS line size, 3⁄4˝ (13mm) connection 120V-1Phase, 60 Hz. 35 psi minimum RIGHT = 12.00˝ 11⁄2˝ dia. NATURAL PROPANE BTU 2 Blowers & Controls 60 psi maximum LEFT = 3.00˝ Do not connect other Piping
3
⁄4˝ N.P.T. Piping 3⁄4˝ N.P.T. 35,000 each 150 watts each C2 3⁄8˝ dia. NPT for Generator REAR = 3.00˝ units to this drain
Supply pressure Supply pressure Generator, C1
3
⁄8˝ dia. NPT for Condenser Allow 6˝ space min.
4.50˝ W.C. Min. 11.00˝ W.C.Min. 70,000 total from rear and sides Drain must be vented
14.00˝ W.C .Max. 14.00˝ W.C.Max. When located near
combustible walls Do not use PVC pipe
Manufacturer must be notified if unit will be used above 2,000 feet
(NOT TO SCALE)
SECT. IV PAGE 12
0402
Litho in U.S.A.
Each Compartment has Capacity for:
• Three 2
1
2˝ x 12˝ x 20˝ Steam Table Pans
• Six 1˝ x 12˝ x 20˝ Steam Table Pans
• Two 4˝ x 12˝ x 20˝ Steam Table Pans
C
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are UL/NSF#4 and CSA (AGA, CGA).
D
WATER QUALITY REQUIREMENTS
The quality of water varies greatly from region to region. Steam equipment generators must be drained daily and chemi­cally descaled periodically to ensure proper operation. To minimize service prob­lems caused by the accu­mulation of minerals and chemicals in water review the following quality guide­lines with a local water treatment specialist. Inlet water that is beyond these specified guidelines should be treated to achieve these acceptable limits. Total Dissolved Solids less than 60 ppm, Alkalinity less than 20 ppm, Silica less than 13 ppm, pH factor greater than 7.5, Chlorine less than 30 ppm.
Right - 3”, Left - 3”, Rear -3”
(12” on control side if adjoining wall or equipment is over 30” high for service access)
Contact factory for variances to clearances.