STEAMCRAFT®GENERATOR STYLE
HIGH SPEED CONVECTION STEAMERS
SteamCraft®GeminiTM10
TWO COMPARTMENT FLOOR MODEL DESIGN
PRESSURELESS CONVECTION STEAMER
TWIN ELECTRIC STEAM GENERATORS, 16 KW EACH
Cleveland Standard Features
I
I
Cooking Capacity for up to ten 12˝ x 20˝ x 21⁄2˝ deep
Cafeteria Pans, five each compartment.
Innovative PowerPak Electric Steam Generator: Twin
II
Vertical Atmospheric Electric Steam Generators operate
independently. Two 8 KW Fire Bar Heating Elements per
generator. Strong 14 Gauge Stainless Steel Construction.
Large 5 gallon generator reservoir for each compartment for
high speed steam cooking production. Two fully insulated
rear mounted independent steam generators.
II
Each steam-cooking compartment is independently
operated and controlled by a separate stainless steel
steam generator.
II
Easy Access Generator Cleaning Port: Two Generator
Cleaning Ports located on the outside, top of the unit.
II
Generator Cleaning Light: Indicator Light located on the
front of the unit warns operator it is time to delime generator.
II
Instant Steam Stand By Mode: Hold generator at a
steaming temperature. Allows unit to start cooking instantly.
II
Durable 14 Gauge, Stainless Steel Construction:
For compartment door, cavity and steam generator.
II
Two 60 Minute Electro-Mechanical Timers and Switches
for manual operation: Audible signal for cooking time
completion. (MCS)
II
Main Power On/Off Switch: Automatically fills generator
with water, and then starts heating elements in generator.
II
Exclusive Steam Cooking Distribution System:
Exclusive Brass Steam Jets produce a high velocity
convection steam without fans. Coved Corner design in
cooking compartment distributes heat evenly, and is easy to
clean. Creased top & bottom enhance drainage. Cold Water
Condenser for each compartment maintains a dry steam.
Fully Insulated cooking compartment for thermal efficiency.
Removable Stainless Steel Slide Racks.
II
Automatic Generator Drain: Contains a “Water Jet” Spray
Rinse Drain Cleaning Cycle to keep drain clear.
II
Exclusive Automatic Probe for Water Level Control:
Separate from the generator for easy access, contains a
high velocity rinse cycle to eliminate mineral build up.
Exclusive “Cool to the Touch” Two-Piece Compartment
II
Door Design: Free floating inner door with reversible gasket provides an air tight seal. Stainless Steel Slam/Latch
Door Latch mechanism for reliability.
II
Condensate Drip Trough: Provide under lower
compartment door to collect condensate.
II
Left Hand Door Hinging: Compartment Doors hinged on
the left, controls on the right.
I NSF Certified 6˝ Stainless Steel Legs with adjustable
flanged feet for a one inch level adjustment.
MODEL: 24-CEA-10
Shown with optional
Electronic Timer
Shown with optional
Electronic Timer
Shall be Two Compartments, Cleveland Convection Steamer series
SteamCraftGeminiTM10
Steam Generator, 32 KW input.
Controls
Generator Blowdown, Two each 16.5 KW Fire Bar Heating Elements. Choice
of Compartment Controls, Manual By Pass Operation Mode, Exclusive Cold
Water Condenser design, Type 430 Stainless Steel exterior and cooking
compartments.
Options & Accessories
Ë Right hand Door Hinging, Controls on the Right (DHR)
Ë Electronic Timer with Compensating Load Feature (ETC)
Ë ON/OFF Steam Switch only for compartment controls (MC)
Ë 10˝ Stainless Steel Legs (LF10)
Ë Dissolve
markings (106174)
Ë Compartment Door Steam Shut Off Switch (SCS)
Ë Cafeteria Pans in depths of 1˝, 2
Ë Low Wattage Option, 8 KW each compartment (LWO)
Ë Water Filters
Short Form Specifications
, Model 24-CEA-10, Twin Electric Atmospheric
. Steam Generator with Automatic Water Fill on start up. Automatic
®
Descale Solution, 6 one gallon container w/quart
Remote Probe Type Water Level
1
⁄2˝ and 4˝
SECT. IV PAGE 15
0609
Each Compartment has capacity for:
• Five, 12˝ x 20˝ x 2
1
⁄2˝ deep Cafeteria Pans.
WATER QUALITY REQUIREMENT
The quality of water varies greatly from region to
region. Steam equipment must be blown down daily
nd chemically descaled periodically to ensure
a
proper operation. To minimize service problems
caused by the accumulation of minerals and chemicals in water, review the following quality guidelines
with a local water treatment specialist. Inlet water that
is beyond these specified guidelines should be
treated to achieve the acceptable limits.
TOTAL DISSOLVED SOLIDS less than 60 parts per million
TOTAL ALKALINITY less than 20 parts per million
SILICA less than 13 parts per million
pH FACTOR greater than 7.5
CHLORINE less than 30 parts per million
A typical water quality analysis can be secured from
your local water district. Water that is potable does
not guarantee compatibility with steam equipment.
COLD WATERELECTRIC
35 psi minimum
Volts Watts Ph Amps Wire
208 32,600 3 91.7 3
220 27,393 3 72.9 3
240 32,600 3 79.5 3
440 27,393 3 36.4 3
480 32,600 3 39.8 3
360 29,259 3 47.6 4
380 32,600 3 50.2 4
415 32,600 3 46.0 4
Volts Watts Ph Amps Wire
208 16,600 3 47.3 3
220 13,948 3 37.6 3
240 16,600 3 41.0 3
440 13,948 3 18.8 3
480 16,600 3 20.5 3
360 14,899 3 24.5 4
380 16,600 3 25.9 4
415 16,600 3 23.7 4
TOTAL CAPACITY (2 Compartments)
10 — 12˝ x 20˝ x 21⁄2˝ Cafeteria Pans or
20 — 12˝ x 20˝ x 1˝ Cafeteria Pans or
26 — 12˝ x 20˝ x 4˝ Cafeteria Pans
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are UL, ULC, UL/NSF#4 and CSA (AGA, CGA).
Electrical Supply Drain: 1.50˝ Dia.
A
B
Cold Water Supply for Condenser 3/8˝ Dia. NPT Inlet for Generator Deliming Solution
Cold Water Supply for Generator and Water Injection.
C
3/8˝ Dia. NPT (for water treatment conn.)
Unit comes with a 50 Mesh Water Strainer (installation required)
60 psi maximum
3
⁄8˝ Dia. NPT for
Generator (for
water treatment
connection)
3
⁄8˝ Dia. NPT for
Condenser
UTILITY CONNECTIONS
D
E
DRAINAGE
11⁄2˝ dia.
Do not connect other units to this
drain
Drain must not be located beneath the
steamer itself. Preferred floor drain
location should be a minimum distance
(from the unit) of at least 12” from the
left side, 12" from the right side, 6” from
the front and 6" from the rear
Do not use PVC pipe
D
CLEARANCE
Right - 3”, Left - 3”,
Rear - 3”
(12” on control side if
adjoining wall or
equipment is over 30”
high for service
access)
Contact factory
for variances to
clearances.
(NOT TO SCALE)